Conduit Outlet Body, Hazardous Location Yes, Conduit Outlet Body Material Iron, Conduit Outlet Body Style T, Conduit Outlet Body Hub Size 1/2 in, Conduit Outlet Body Hub Style Threaded, Conduit Outlet Body Capacity 3.0 cu. in., Back Type Round, Gray, Standards UL 886, CSA C22.2 No. 25, C22.2 No. 30, UL Listed for Class I, Division 1 and 2, Groups B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Form 1
Conduit Outlet Body, Hazardous Location Yes, Conduit Outlet Body Material Iron, Conduit Outlet Body Style T, Conduit Outlet Body Hub Size 1/2 in, Conduit Outlet Body Hub Style Threaded, Conduit Outlet Body Capacity 3.0 cu. in., Back Type Round, Gray, Standards UL 886, CSA C22.2 No. 25, C22.2 No. 30, UL Listed for Class I, Division 1 and 2, Groups B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Form 1
Conduit Outlet Body, Hazardous Location Yes, Conduit Outlet Body Material Iron, Conduit Outlet Body Style T, Conduit Outlet Body Hub Size 1 in, Conduit Outlet Body Hub Style Threaded, Conduit Outlet Body Capacity 3.0 cu. in., Back Type Round, Gray, Standards UL 886, CSA C22.2 No. 25, C22.2 No. 30, UL Listed for Class I, Division 1 and 2, Groups B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Form 1
Conduit Outlet Body, Hazardous Location Yes, Conduit Outlet Body Material Iron, Conduit Outlet Body Style T, Conduit Outlet Body Hub Size 1 in, Conduit Outlet Body Hub Style Threaded, Conduit Outlet Body Capacity 3.0 cu. in., Back Type Round, Gray, Standards UL 886, CSA C22.2 No. 25, C22.2 No. 30, UL Listed for Class I, Division 1 and 2, Groups B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Form 1
Conduit Outlet Body, Hazardous Location Yes, Conduit Outlet Body Material Iron, Conduit Outlet Body Style T, Conduit Outlet Body Hub Size 3/4 in, Conduit Outlet Body Hub Style Threaded, Conduit Outlet Body Capacity 3.0 cu. in., Back Type Round, Gray, Standards UL 886, CSA C22.2 No. 25, C22.2 No. 30, UL Listed for Class I, Division 1 and 2, Groups B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Form 1
Conduit Outlet Body, Hazardous Location Yes, Conduit Outlet Body Material Iron, Conduit Outlet Body Style T, Conduit Outlet Body Hub Size 3/4 in, Conduit Outlet Body Hub Style Threaded, Conduit Outlet Body Capacity 3.0 cu. in., Back Type Round, Gray, Standards UL 886, CSA C22.2 No. 25, C22.2 No. 30, UL Listed for Class I, Division 1 and 2, Groups B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Form 1
Conduit Outlet Body, Hazardous Location Yes, Conduit Outlet Body Material Copper Free Aluminum, Conduit Outlet Body Style 7 Hub, Conduit Outlet Body Hub Size 1 in, Conduit Outlet Body Hub Style Threaded, Conduit Outlet Body Capacity 3.0 cu. in., Back Type Flat, Gray, Special Features 7 Hub. 2 On Each Side, 1 On Top and Bottom, 1 On Back
Conduit Outlet Body, Hazardous Location Yes, Conduit Outlet Body Material Copper Free Aluminum, Conduit Outlet Body Style 7 Hub, Conduit Outlet Body Hub Size 1 in, Conduit Outlet Body Hub Style Threaded, Conduit Outlet Body Capacity 3.0 cu. in., Back Type Flat, Gray, Special Features 7 Hub. 2 On Each Side, 1 On Top and Bottom, 1 On Back
Conduit Outlet Body, Hazardous Location No, Conduit Outlet Body Material Copper Free Aluminum, Conduit Outlet Body Style T, Conduit Outlet Body Hub Size 3/4 in, Conduit Outlet Body Hub Style Threaded, Conduit Outlet Body Capacity 3.0 cu. in., Back Type Flat, Gray, Form 7
Conduit Outlet Body, Hazardous Location No, Conduit Outlet Body Material Copper Free Aluminum, Conduit Outlet Body Style T, Conduit Outlet Body Hub Size 3/4 in, Conduit Outlet Body Hub Style Threaded, Conduit Outlet Body Capacity 3.0 cu. in., Back Type Flat, Gray, Form 7
Zoro also carries a PVC electrical conduit model, resistant to sunlight and corrosion. Hubbell Killark Conduit Body Gasket include characteristics like: Material: Neoprene Rubber, For Use With: Hubbell Killark Copper Free Aluminum Conduit Bodies.
Zoro also carries a PVC electrical conduit model, resistant to sunlight and corrosion. Hubbell Killark Conduit Body Gasket include characteristics like: Material: Neoprene Rubber, For Use With: Hubbell Killark Copper Free Aluminum Conduit Bodies.
For instance, if you were installing the wiring for an outdoor floodlight, the metal conduit is where two cables/wires come together. Take a look at the features for Hubbell Killark Conduit Outlet Body w/Cover. Color: Gray.
For instance, if you were installing the wiring for an outdoor floodlight, the metal conduit is where two cables/wires come together. Take a look at the features for Hubbell Killark Conduit Outlet Body w/Cover. Color: Gray.
Conduit Outlet Body, Hazardous Location No, Conduit Outlet Body Material Copper Free Aluminum, Conduit Outlet Body Style C, Conduit Outlet Body Hub Size 1/2 in, Conduit Outlet Body Hub Style Threaded, Conduit Outlet Body Capacity 3.0 cu. in., Back Type Flat, Gray, Special Features NPT Tapered Threaded Hub, Form 85
Conduit Outlet Body, Hazardous Location No, Conduit Outlet Body Material Copper Free Aluminum, Conduit Outlet Body Style C, Conduit Outlet Body Hub Size 1/2 in, Conduit Outlet Body Hub Style Threaded, Conduit Outlet Body Capacity 3.0 cu. in., Back Type Flat, Gray, Special Features NPT Tapered Threaded Hub, Form 85
Union, Ends - Hazardous Fittings 1/2 In. FNPT x 1/2 In. FNPT, Overall Length - Fitting 1-7/8 In., Conduit Fitting Material Copper Free Aluminum, Hazardous Location Rating Class I, Division 1 and 2, Groups A, B, C, D; Class I, Zone 1, Groups IIC, IIB, IIA; Class II, Division 1 and 2, Groups E, F, G; Class III, Standards UL 886, CSA C22.2 No. 30, Application Unions Are Used To Connect Two Pieces Of Conduit Or Attach Conduit To Junction Boxes, Fittings Or Devices
Union, Ends - Hazardous Fittings 1/2 In. FNPT x 1/2 In. FNPT, Overall Length - Fitting 1-7/8 In., Conduit Fitting Material Copper Free Aluminum, Hazardous Location Rating Class I, Division 1 and 2, Groups A, B, C, D; Class I, Zone 1, Groups IIC, IIB, IIA; Class II, Division 1 and 2, Groups E, F, G; Class III, Standards UL 886, CSA C22.2 No. 30, Application Unions Are Used To Connect Two Pieces Of Conduit Or Attach Conduit To Junction Boxes, Fittings Or Devices
Hub, Rain Tight, For Conduit Type Rigid, Conduit Fitting Type Hub, Conduit Trade Size 1-1/4 In., Conduit Fitting Material Zinc, Overall Length 1-7/8 In., For Use With Rigid Conduit
Hub, Rain Tight, For Conduit Type Rigid, Conduit Fitting Type Hub, Conduit Trade Size 1-1/4 In., Conduit Fitting Material Zinc, Overall Length 1-7/8 In., For Use With Rigid Conduit
Explosionproof Box and Cover, Finish Gray, Suface Mounting, Depth (In.) 3 in, Height (In.) 4 1/2 in, Length (In.) 4 1/2 in, For Use With 302-EPM
Explosionproof Box and Cover, Finish Gray, Suface Mounting, Depth (In.) 3 in, Height (In.) 4 1/2 in, Length (In.) 4 1/2 in, For Use With 302-EPM
Electrical conduit bodies look like rounded rectangles with a piping connector at one or both ends. Take a look at the features for Raco Pulling Elbow. Color: Silver.
Electrical conduit bodies look like rounded rectangles with a piping connector at one or both ends. Take a look at the features for Raco Pulling Elbow. Color: Silver.