Fasco D119
We have the fasco d119 you need to get the job done right.
Featured Product
FASCO Motor, 1/11, 1/25, 1/70 HP, OEM Replacement Brand: Camco Replacement For: 2868-405-173
Zoro # G4334185 Mfr # D119Condenser Fan Motor, Single Phase, Motor Design Shaded Pole, 1/11, 1/25, 1/70 HP, Nameplate RPM 1, 500, No. of Speeds 3, Voltage 115V AC, Full Load Amps 2.9/1.50/1.00, 3.3 in Frame, OEM Replacement Brand Camco, Replacement For 2868-405-173, Usable @ 208V No, Usable @ 200V No, 60 Hz, Motor Service Factor 1, Motor Thermal Protection Auto, Ins. Class B, Max. Ambient Temp. 40 Degrees C, Motor Shaft Rotation CCWSE, Motor Enclosure Design Open Air-Over, Motor Mounting Type Stud
View Full Product DetailsCondenser Fan Motor, Single Phase, Motor Design Shaded Pole, 1/11, 1/25, 1/70 HP, Nameplate RPM 1, 500, No. of Speeds 3, Voltage 115V AC, Full Load Amps 2.9/1.50/1.00, 3.3 in Frame, OEM Replacement Brand Camco, Replacement For 2868-405-173, Usable @ 208V No, Usable @ 200V No, 60 Hz, Motor Service Factor 1, Motor Thermal Protection Auto, Ins. Class B, Max. Ambient Temp. 40 Degrees C, Motor Shaft Rotation CCWSE, Motor Enclosure Design Open Air-Over, Motor Mounting Type Stud
View Full Product DetailsShop Fasco D119
OEM Replacement Motor, Single Phase, Motor Design Shaded Pole, 1/20 HP, Nameplate RPM 1, 550, No. of Speeds 1, Voltage 115V AC, Full Load Amps 2.1, 3.3 in Frame, Usable @ 208V No, Usable @ 200V No, Motor Thermal Protection Auto, 60 Hz, Motor Service Factor 1, Ins. Class B, Motor Shaft Rotation CWSE, Max. Ambient Temp. 40 Degrees C, Lead Length 13 in, Motor Enclosure Design Open Air-Over, Motor Mounting Type Extended Stud, Number of Shafts 1
View Full Product DetailsOEM Replacement Motor, Single Phase, Motor Design Shaded Pole, 1/20 HP, Nameplate RPM 1, 550, No. of Speeds 1, Voltage 115V AC, Full Load Amps 2.1, 3.3 in Frame, Usable @ 208V No, Usable @ 200V No, Motor Thermal Protection Auto, 60 Hz, Motor Service Factor 1, Ins. Class B, Motor Shaft Rotation CWSE, Max. Ambient Temp. 40 Degrees C, Lead Length 13 in, Motor Enclosure Design Open Air-Over, Motor Mounting Type Extended Stud, Number of Shafts 1
View Full Product DetailsDouble Loop Ties, Baling Wire Type Wire Ties, Wire Finish Bare Wire, Wire Gauge 16 ga, Wire Diameter 0.0625 in, Length 0.5 ft, Break Strength 155 lb, Material Black Annealed Wire, Number of Loops Double Loop, Package Quantity 5000
View Full Product DetailsDouble Loop Ties, Baling Wire Type Wire Ties, Wire Finish Bare Wire, Wire Gauge 16 ga, Wire Diameter 0.0625 in, Length 0.5 ft, Break Strength 155 lb, Material Black Annealed Wire, Number of Loops Double Loop, Package Quantity 5000
View Full Product DetailsThis Condenser Fan Motor is a great OEM replacement motor for your condenser fan. It has a shaded pole motor design with a single phase motor. The motor is 115 volts, 1/20 horsepower, and has a CWSE motor shaft rotation. This motor is designed to be used as an OEM replacement motor for the brand Heatcraft. This motor has an open air-over motor enclosure enclosure. It features a sleeve bearing, so it is designed for lower maintenance and longer life.
View Full Product DetailsThis Condenser Fan Motor is a great OEM replacement motor for your condenser fan. It has a shaded pole motor design with a single phase motor. The motor is 115 volts, 1/20 horsepower, and has a CWSE motor shaft rotation. This motor is designed to be used as an OEM replacement motor for the brand Heatcraft. This motor has an open air-over motor enclosure enclosure. It features a sleeve bearing, so it is designed for lower maintenance and longer life.
View Full Product DetailsDraft Inducer, Inlet and Outlet Dia. (In.) 2.0/1.7, Voltage 115, Height (In.) 9 7/64 in, Width (In.) 6 25/32 in, Depth (In.) 10 29/32 in, Furnace, Construction Material Plastic, Agency Compliance CSA Motor Only, UL, Replaces Fasco 702111577, 702111577S, 702111830, York 024-34558-000, 17503, Fits Brand York, For Use With Mfr. Model Number 024-34558-000, 17503, 7021-11577, 7021-11577S, 7021-11830, 76, 68, 65, 60, 54
View Full Product DetailsDraft Inducer, Inlet and Outlet Dia. (In.) 2.0/1.7, Voltage 115, Height (In.) 9 7/64 in, Width (In.) 6 25/32 in, Depth (In.) 10 29/32 in, Furnace, Construction Material Plastic, Agency Compliance CSA Motor Only, UL, Replaces Fasco 702111577, 702111577S, 702111830, York 024-34558-000, 17503, Fits Brand York, For Use With Mfr. Model Number 024-34558-000, 17503, 7021-11577, 7021-11577S, 7021-11830, 76, 68, 65, 60, 54
View Full Product DetailsDirect Drive Blower Motor, Single Phase, Motor Design Shaded Pole, 1/50 HP, Nameplate RPM 1, 500, No. of Speeds 1, Voltage 115V AC, Full Load Amps 0.80, 3.3 in Frame, Usable @ 208V No, Usable @ 200V No, Motor Thermal Protection Auto, 60 Hz, Motor Service Factor 1, Ins. Class B, Motor Shaft Rotation CWSE, Max. Ambient Temp. 40 Degrees C, Lead Length 12 in, Motor Enclosure Design Totally Enclosed Air-Over, Motor Mounting Type Extended Stud, Motor Mounting Position All Angle, Number of Shafts 1
View Full Product DetailsDirect Drive Blower Motor, Single Phase, Motor Design Shaded Pole, 1/50 HP, Nameplate RPM 1, 500, No. of Speeds 1, Voltage 115V AC, Full Load Amps 0.80, 3.3 in Frame, Usable @ 208V No, Usable @ 200V No, Motor Thermal Protection Auto, 60 Hz, Motor Service Factor 1, Ins. Class B, Motor Shaft Rotation CWSE, Max. Ambient Temp. 40 Degrees C, Lead Length 12 in, Motor Enclosure Design Totally Enclosed Air-Over, Motor Mounting Type Extended Stud, Motor Mounting Position All Angle, Number of Shafts 1
View Full Product DetailsDirect Drive Blower Motor, Single Phase, Motor Design Shaded Pole, 1/20 HP, Nameplate RPM 1, 500, No. of Speeds 1, Voltage 230V AC, Full Load Amps 0.90, 3.3 in Frame, Usable @ 208V No, Usable @ 200V No, Motor Thermal Protection Auto, 60 Hz, Motor Service Factor 1, Ins. Class B, Motor Shaft Rotation CCWSE, Max. Ambient Temp. 40 Degrees C, Lead Length 12 in, Motor Enclosure Design Open Air-Over, Motor Mounting Type Extended Stud, Motor Mounting Position All Angle, Number of Shafts 1
View Full Product DetailsDirect Drive Blower Motor, Single Phase, Motor Design Shaded Pole, 1/20 HP, Nameplate RPM 1, 500, No. of Speeds 1, Voltage 230V AC, Full Load Amps 0.90, 3.3 in Frame, Usable @ 208V No, Usable @ 200V No, Motor Thermal Protection Auto, 60 Hz, Motor Service Factor 1, Ins. Class B, Motor Shaft Rotation CCWSE, Max. Ambient Temp. 40 Degrees C, Lead Length 12 in, Motor Enclosure Design Open Air-Over, Motor Mounting Type Extended Stud, Motor Mounting Position All Angle, Number of Shafts 1
View Full Product DetailsDirect Drive Blower Motor, Single Phase, Motor Design Shaded Pole, 1/15 HP, Nameplate RPM 1, 600, No. of Speeds 1, Voltage 115V AC, Full Load Amps 2.00, 3.3 in Frame, Usable @ 208V No, Usable @ 200V No, Motor Thermal Protection Auto, 60 Hz, Motor Service Factor 1, Ins. Class B, Motor Shaft Rotation CWSE, Max. Ambient Temp. 40 Degrees C, Lead Length 12 in, 16 in, Motor Enclosure Design Open Air-Over, Motor Mounting Type Extended Stud, Motor Mounting Position All Angle, Number of Shafts 1
View Full Product DetailsDirect Drive Blower Motor, Single Phase, Motor Design Shaded Pole, 1/15 HP, Nameplate RPM 1, 600, No. of Speeds 1, Voltage 115V AC, Full Load Amps 2.00, 3.3 in Frame, Usable @ 208V No, Usable @ 200V No, Motor Thermal Protection Auto, 60 Hz, Motor Service Factor 1, Ins. Class B, Motor Shaft Rotation CWSE, Max. Ambient Temp. 40 Degrees C, Lead Length 12 in, 16 in, Motor Enclosure Design Open Air-Over, Motor Mounting Type Extended Stud, Motor Mounting Position All Angle, Number of Shafts 1
View Full Product DetailsInduced Draft Furnace Blower, U21B, Voltage 115, 1.4 Amps, 107 W Watts, 1/50 hp HP, Height (In.) 9 7/8 in, Width (In.) 9 in, Depth (In.) 6 3/8 in, Gas Furnaces, Construction Material Plastic, Agency Compliance CSA, UL, Replaces Alltemp (Rotom) FB-RFB140, 70219915, Fasco70219087, 70219565, Goodman B2833001, Product Used as Direct OEM Replacement Only. Any Other use Constitutes a Misapplication, Which Voids the Warranty and May Create Unsafe Conditions, Fits Brand Goodman
View Full Product DetailsInduced Draft Furnace Blower, U21B, Voltage 115, 1.4 Amps, 107 W Watts, 1/50 hp HP, Height (In.) 9 7/8 in, Width (In.) 9 in, Depth (In.) 6 3/8 in, Gas Furnaces, Construction Material Plastic, Agency Compliance CSA, UL, Replaces Alltemp (Rotom) FB-RFB140, 70219915, Fasco70219087, 70219565, Goodman B2833001, Product Used as Direct OEM Replacement Only. Any Other use Constitutes a Misapplication, Which Voids the Warranty and May Create Unsafe Conditions, Fits Brand Goodman
View Full Product DetailsFASCO Motor, 1/3 HP, OEM Replacement Brand: Coleman Replacement For: Coleman Mfr. No. 1468-306, 1468-3069
Zoro # G4335217 Mfr # D1092OEM Replacement Motor, Single Phase, Motor Design Permanent Split Capacitor, 1/3 HP, Nameplate RPM 1, 675/1, 080, No. of Speeds 2, Voltage 115V AC, Full Load Amps 3.4, 42 Frame, OEM Replacement Brand Coleman, Replacement For Coleman Mfr. No. 1468-306, 1468-3069, Usable @ 208V No, Usable @ 200V No, 60 Hz, Motor Service Factor 1, Motor Thermal Protection Auto, Ins. Class B, Max. Ambient Temp. 40 Degrees C, Duty Cycle Continuous, Motor Shaft Rotation CCWSE, Motor Enclosure Design Open Air-Over
View Full Product DetailsOEM Replacement Motor, Single Phase, Motor Design Permanent Split Capacitor, 1/3 HP, Nameplate RPM 1, 675/1, 080, No. of Speeds 2, Voltage 115V AC, Full Load Amps 3.4, 42 Frame, OEM Replacement Brand Coleman, Replacement For Coleman Mfr. No. 1468-306, 1468-3069, Usable @ 208V No, Usable @ 200V No, 60 Hz, Motor Service Factor 1, Motor Thermal Protection Auto, Ins. Class B, Max. Ambient Temp. 40 Degrees C, Duty Cycle Continuous, Motor Shaft Rotation CCWSE, Motor Enclosure Design Open Air-Over
View Full Product DetailsDirect Drive Blower Motor, Single Phase, Motor Design Permanent Split Capacitor, 1/3 to 1/4 to 1/5 HP, Nameplate RPM 1, 075, No. of Speeds 3, Voltage 115V AC, Full Load Amps 5.9-4.6-3.8, 48 Frame, Usable @ 208V No, Usable @ 200V No, Motor Thermal Protection Auto, 60 Hz, Motor Service Factor 1, Ins. Class B, Motor Shaft Rotation CW/CCW, Max. Ambient Temp. 40 Degrees C, Duty Cycle Continuous, Lead Length 26 in, Motor Enclosure Design Open Dripproof, Motor Mounting Type Extended Stud
View Full Product DetailsDirect Drive Blower Motor, Single Phase, Motor Design Permanent Split Capacitor, 1/3 to 1/4 to 1/5 HP, Nameplate RPM 1, 075, No. of Speeds 3, Voltage 115V AC, Full Load Amps 5.9-4.6-3.8, 48 Frame, Usable @ 208V No, Usable @ 200V No, Motor Thermal Protection Auto, 60 Hz, Motor Service Factor 1, Ins. Class B, Motor Shaft Rotation CW/CCW, Max. Ambient Temp. 40 Degrees C, Duty Cycle Continuous, Lead Length 26 in, Motor Enclosure Design Open Dripproof, Motor Mounting Type Extended Stud
View Full Product DetailsDirect Drive Blower Motor, Single Phase, Motor Design Shaded Pole, 1/50 HP, Nameplate RPM 3, 000, No. of Speeds 1, Voltage 115V AC, Full Load Amps 0.92, 3.3 in Frame, Usable @ 208V No, Usable @ 200V No, Motor Thermal Protection Auto, 60 Hz, Motor Service Factor 1, Ins. Class B, Motor Shaft Rotation CWSE, Max. Ambient Temp. 40 Degrees C, Lead Length 18 in, Motor Enclosure Design Open Air-Over, Motor Mounting Type Extended Stud, Motor Mounting Position All Angle, Number of Shafts 1
View Full Product DetailsDirect Drive Blower Motor, Single Phase, Motor Design Shaded Pole, 1/50 HP, Nameplate RPM 3, 000, No. of Speeds 1, Voltage 115V AC, Full Load Amps 0.92, 3.3 in Frame, Usable @ 208V No, Usable @ 200V No, Motor Thermal Protection Auto, 60 Hz, Motor Service Factor 1, Ins. Class B, Motor Shaft Rotation CWSE, Max. Ambient Temp. 40 Degrees C, Lead Length 18 in, Motor Enclosure Design Open Air-Over, Motor Mounting Type Extended Stud, Motor Mounting Position All Angle, Number of Shafts 1
View Full Product DetailsExplore more
- eaton soft start motor controllers
- usem 3-phase ac motors
- century unit heater motors
- california air tools ac air compressor motors
- dayton pressure washer motors
- titus oem replacement motors
- envirotec oem replacement motors
- dayton carbonator pump motors
- airmaster fan pedestal fan motors
- marathon motors ac farm duty motors
- dcm permanent split capacitor condenser fan motors
- century motor parts