Gas Detector, Controller, Transducer, Gas Type O2, Number of Channels 2, Sensor Range 0 to 25 Percent v/v, Resolution .1 Percent vol, Alarm Type Audible and Visual, Display LED, Status Indicator Yes, Features Powered by Line Voltage, ETL Listed, Supervised System Design, Detector Problem Will Cause the Fan and Alarm Relay to Activate, 2-3 Year Sensor Life, Replaceable Sensor, End of Life Indication, Digital Readout Display, Internal Buzzer, Onboard Relays (2), 4-20mA Transduced current loop
Gas Detector, Controller, Transducer, Gas Type O2, Number of Channels 2, Sensor Range 0 to 25 Percent v/v, Resolution .1 Percent vol, Alarm Type Audible and Visual, Display LED, Status Indicator Yes, Features Powered by Line Voltage, ETL Listed, Supervised System Design, Detector Problem Will Cause the Fan and Alarm Relay to Activate, 2-3 Year Sensor Life, Replaceable Sensor, End of Life Indication, Digital Readout Display, Internal Buzzer, Onboard Relays (2), 4-20mA Transduced current loop
Horn Strobe Alarm, Length 4 3/4 in, Width 2 in, Depth 2 in, Height 5 1/2 in, Status Indicator LED, Power Source 16 to 33V DC, Features Adjustable Amber Strobe, Adjustable Audible Tone Settings, Low Current Draw, For Use With Mfr. No. DVP-120M, CM-6, GD-6, TX-6-ND, TX-6-HS, TX-6-AM, OX-6, RD-6, 70-2900-0011-9, Includes Mounting Screws
Horn Strobe Alarm, Length 4 3/4 in, Width 2 in, Depth 2 in, Height 5 1/2 in, Status Indicator LED, Power Source 16 to 33V DC, Features Adjustable Amber Strobe, Adjustable Audible Tone Settings, Low Current Draw, For Use With Mfr. No. DVP-120M, CM-6, GD-6, TX-6-ND, TX-6-HS, TX-6-AM, OX-6, RD-6, 70-2900-0011-9, Includes Mounting Screws
Gas Detector, Controller, Transducer, Gas Type CO, Number of Channels 2, Sensor Range 0 to 200 ppm, Resolution 1 ppm, Alarm Type Audible and Visual, Display LED, Status Indicator Yes, Features Powered by Low Voltage, ETL Listed, Supervised System Design, Detector Problem Will Cause the Fan and Alarm Relay to Activate, 7 Year Life, End of Life Indication, Digital Readout Display, Internal Buzzer, Onboard Relays (2), 4-20mA Transduced current loop, Connection Plugs/Terminals
Gas Detector, Controller, Transducer, Gas Type CO, Number of Channels 2, Sensor Range 0 to 200 ppm, Resolution 1 ppm, Alarm Type Audible and Visual, Display LED, Status Indicator Yes, Features Powered by Low Voltage, ETL Listed, Supervised System Design, Detector Problem Will Cause the Fan and Alarm Relay to Activate, 7 Year Life, End of Life Indication, Digital Readout Display, Internal Buzzer, Onboard Relays (2), 4-20mA Transduced current loop, Connection Plugs/Terminals
Soldering Heat Sink, Measure To Protect Heat Sensitive Components From Thermal Damage, For Thermal Damage Prevention on Heat-Sensitive Components, Length 1 in, Color Copper, Material Copper, For Use With Mfr. No. PSK25
Soldering Heat Sink, Measure To Protect Heat Sensitive Components From Thermal Damage, For Thermal Damage Prevention on Heat-Sensitive Components, Length 1 in, Color Copper, Material Copper, For Use With Mfr. No. PSK25
Fixed Gas Detector, Gas Type C3H8, CH4, Number of Channels 2, Sensor Range 0 to 25 Percent LEL, Resolution N/A, Alarm Type Visual, Display No, Status Indicator Yes, Features Flush or Surface Mount, Low Profile, 7-10 Year Life, UL Listed, CSFM Approved, Designed for Connection to Fire Alarm and Burglary Alarm Panels, Connection Plugs/Terminals, For Use With Fire Alarm Panels, Burglary Alarm Panels, Power Required 12 to 24V AC/DC, Height 4 in, Width 5 in, Depth 1 5/8 in, Color White
Fixed Gas Detector, Gas Type C3H8, CH4, Number of Channels 2, Sensor Range 0 to 25 Percent LEL, Resolution N/A, Alarm Type Visual, Display No, Status Indicator Yes, Features Flush or Surface Mount, Low Profile, 7-10 Year Life, UL Listed, CSFM Approved, Designed for Connection to Fire Alarm and Burglary Alarm Panels, Connection Plugs/Terminals, For Use With Fire Alarm Panels, Burglary Alarm Panels, Power Required 12 to 24V AC/DC, Height 4 in, Width 5 in, Depth 1 5/8 in, Color White
Fixed Gas Detector, Gas Type CO, Number of Channels 2, Sensor Range 0 to 400 ppm, Resolution N/A, Alarm Type Audible and Visual, Display No, Status Indicator Yes, Features Flush or Surface Mount, Low Profile, 10 Year Life, UL Listed, CSFM Approved, Gas Test Functionality, End of Life Indication, Designed for Connection to Fire Alarm and Burglary Alarm Panels, Connection Wire Harness, For Use With Fire Alarm Panels, Burglary Alarm Panels, Power Required 9 to 32V DC, Height 5 1/8 in
Fixed Gas Detector, Gas Type CO, Number of Channels 2, Sensor Range 0 to 400 ppm, Resolution N/A, Alarm Type Audible and Visual, Display No, Status Indicator Yes, Features Flush or Surface Mount, Low Profile, 10 Year Life, UL Listed, CSFM Approved, Gas Test Functionality, End of Life Indication, Designed for Connection to Fire Alarm and Burglary Alarm Panels, Connection Wire Harness, For Use With Fire Alarm Panels, Burglary Alarm Panels, Power Required 9 to 32V DC, Height 5 1/8 in
Control Panel, Number of Inputs 12, Number of Outputs 3, Output Type Relay, Output Rating 10A, Alarm Type Internal Buzzer, Power Required 100/240VAC, Height 10 In., Width 12 In., Depth 2 In., Standards ETL Listed to UL 508A, CAN/CSA-C22.2 No. 14-13
Control Panel, Number of Inputs 12, Number of Outputs 3, Output Type Relay, Output Rating 10A, Alarm Type Internal Buzzer, Power Required 100/240VAC, Height 10 In., Width 12 In., Depth 2 In., Standards ETL Listed to UL 508A, CAN/CSA-C22.2 No. 14-13
Gas Detector, Controller, Transducer, Gas Type NO2, Number of Channels 2, Sensor Range 0 to 20 ppm, Resolution 1 ppm, Alarm Type Audible and Visual, Display LED, Status Indicator Yes, Features Powered by Low Voltage, ETL Listed, Supervised System Design, Detector Problem Will Cause the Fan and Alarm Relay to Activate, 2-3 Year Sensor Life, Replaceable Sensor, End of Life Indication, Digital Readout Display, Internal Buzzer, Onboard Relays (2), 4-20mA Transduced current loop
Gas Detector, Controller, Transducer, Gas Type NO2, Number of Channels 2, Sensor Range 0 to 20 ppm, Resolution 1 ppm, Alarm Type Audible and Visual, Display LED, Status Indicator Yes, Features Powered by Low Voltage, ETL Listed, Supervised System Design, Detector Problem Will Cause the Fan and Alarm Relay to Activate, 2-3 Year Sensor Life, Replaceable Sensor, End of Life Indication, Digital Readout Display, Internal Buzzer, Onboard Relays (2), 4-20mA Transduced current loop
Gas Detector, Controller, Transducer, Gas Type C3H8, CH4, H2, Number of Channels 2, Sensor Range 0 to 50 Percent LEL, Resolution 1 Percent LEL, Alarm Type Audible and Visual, Display LED, Status Indicator Yes, Features Powered by Low Voltage, ETL Listed, Supervised System Design, Detector Problem Will Cause the Fan and Alarm Relay to Activate, 5 Year Life, End of Life Indication, Digital Readout Display, Internal Buzzer, Onboard Relays (2), 4-20mA Transduced current loop
Gas Detector, Controller, Transducer, Gas Type C3H8, CH4, H2, Number of Channels 2, Sensor Range 0 to 50 Percent LEL, Resolution 1 Percent LEL, Alarm Type Audible and Visual, Display LED, Status Indicator Yes, Features Powered by Low Voltage, ETL Listed, Supervised System Design, Detector Problem Will Cause the Fan and Alarm Relay to Activate, 5 Year Life, End of Life Indication, Digital Readout Display, Internal Buzzer, Onboard Relays (2), 4-20mA Transduced current loop
Gas Detector, Controller, Transducer, Gas Type CO2, Number of Channels 0, Sensor Range 0 to 5000 ppm, Resolution 10 ppm, Control Type 4 to 20mA, Alarm Type Audible and Visual, Display LED, Status Indicator Yes, Features Manual Calibration, Powered By Line Voltage, Supervised System Design, Detector Problem Will Cause The Fan and Alarm Relay to Activate, 15 yr Life, End of Life Indication, Digital Readout Display, Internal Buzzer, (2) Onboard Relays, 4 to 20mA Transduced Current Loop
Gas Detector, Controller, Transducer, Gas Type CO2, Number of Channels 0, Sensor Range 0 to 5000 ppm, Resolution 10 ppm, Control Type 4 to 20mA, Alarm Type Audible and Visual, Display LED, Status Indicator Yes, Features Manual Calibration, Powered By Line Voltage, Supervised System Design, Detector Problem Will Cause The Fan and Alarm Relay to Activate, 15 yr Life, End of Life Indication, Digital Readout Display, Internal Buzzer, (2) Onboard Relays, 4 to 20mA Transduced Current Loop
Gas Detector, Controller, Transducer, Gas Type C3H8, CH4, H2, Number of Channels 2, Sensor Range 0 to 50 Percent LEL, Resolution 1 Percent LEL, Alarm Type Audible and Visual, Display LED, Status Indicator Yes, Features Powered by Line Voltage, ETL Listed, Supervised System Design, Detector Problem Will Cause the Fan and Alarm Relay to Activate, 5 Year Life, End of Life Indication, Digital Readout Display, Internal Buzzer, Onboard Relays (2), 4-20mA Transduced current loop
Gas Detector, Controller, Transducer, Gas Type C3H8, CH4, H2, Number of Channels 2, Sensor Range 0 to 50 Percent LEL, Resolution 1 Percent LEL, Alarm Type Audible and Visual, Display LED, Status Indicator Yes, Features Powered by Line Voltage, ETL Listed, Supervised System Design, Detector Problem Will Cause the Fan and Alarm Relay to Activate, 5 Year Life, End of Life Indication, Digital Readout Display, Internal Buzzer, Onboard Relays (2), 4-20mA Transduced current loop
Gas Detector, Gas Type H2, Number of Channels 2, Sensor Range 0 to 10 Percent LEL, Resolution N/A, Alarm Type Visual, Display No, Status Indicator Yes, Features Flush or Surface Mount, Low Profile, 7-10 Year Life, Designed for Connection to Fire Alarm and Burglary Alarm Panels, Connection Plugs/Terminals, For Use With Fire Alarm Panels, Burglary Alarm Panels, Power Required 12 to 24V AC/DC, Height 4 in, Width 5 in, Depth 1 5/8 in, Color White
Gas Detector, Gas Type H2, Number of Channels 2, Sensor Range 0 to 10 Percent LEL, Resolution N/A, Alarm Type Visual, Display No, Status Indicator Yes, Features Flush or Surface Mount, Low Profile, 7-10 Year Life, Designed for Connection to Fire Alarm and Burglary Alarm Panels, Connection Plugs/Terminals, For Use With Fire Alarm Panels, Burglary Alarm Panels, Power Required 12 to 24V AC/DC, Height 4 in, Width 5 in, Depth 1 5/8 in, Color White