- Home
- /
- Electrical Supplies
- /
- Industrial Control & Automation
- /
- Motor Controls
- /
- Contactors & Contacts
- /
- IEC Magnetic Contactors
- /
- IEC Magnetic Contactor, 3 Poles, 120 V AC, 25 A, Reversing: No
Schneider Electric
IEC Magnetic Contactor, 3 Poles, 120 V AC, 25 A, Reversing: No
Mfr # LC1D25G7
Zoro # G0464597
Free Shipping & Returns
$177.99
Item successfully saved to ''
Free Shipping on orders over $50
after you
Free 30-Day Returns
Key Features
- Full Load Amps-Inductive 25 A
- Action Non-Reversing
- Full Load Amps-Resistive 40 A
- Number of Poles 3
- Coil Volts 120 V AC
Customers Also Purchased
- Brand Schneider Electric
-
MFR #
LC1D25G7
-
Zoro #
G0464597
- UPC # 785901207153
- Country of Origin Indonesia
- Category IEC Magnetic Contactors
Dimensions
Width | 1.77 in |
Height | 3.36 in |
Depth | 3.62 in |
NEMA Size | Not Applicable |
Working Height | Up to 9842.52 ft |
Overall Height | 3.35 in |
Overall Depth | 3.62 in |
Overall Width | 1.77 in |
Details
Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 25 A |
Action | Non-Reversing |
Full Load Amps-Resistive | 40 A |
Number of Poles | 3 |
Coil Volts | 120 V AC |
Reversing | No |
HP @ 1 Phase - 230V | 3 |
HP @ 1 Phase - 120V | 2 hp |
HP @ 1 Phase - 240V | 3 hp |
HP @ 3 Phase - 208V | 7 1/2 hp |
HP @ 3 Phase - 240V | 7 1/2 hp |
HP @ 3 Phase - 480V | 15 hp |
HP @ 3 Phase - 575V | 20 hp |
Aux. Contact Configuration | 1NO/1NC |
Enclosure NEMA Rating | No Enclosure |
Hz | 50/60 |
Auxiliary Contact Form | 1NO/1NC |
Frame / Series / Class / Code | TeSys |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Series | TeSys Deca |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Max. Temperature | 850°C |
Net Weight | 0.37 kg |
Watts Loss | 2 to 3W |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit) |
Fire Rating | UL 94 V1 |
Rated Insulation Volts | 600/690V |
Electrical Connection | Screw Clamp Terminals |
Mechanical Durability | 15 Mcycles |
Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit) |
Impulse Withstand Voltage | 6 kV |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Inrush VA | 70 VA |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit) |
Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Mounts On | Plate, Rail |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Impedance | 2 mOhm |
Rated Voltage | 690V AC, 300V DC |
Rated Short-Time Withstand Current | 240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Includes Protective Cover | Yes |
Rated Breaking Capacity | 450 A @ 440V |
Features | Without Built-In Suppressor Module |
Application | Motor Control, Resistive Load |
Max. Operating Watts | 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 415 to 440V AC 50/60 Hz AC-3), 15 kW (at 500V AC 50/60 Hz AC-3), 15 kW (at 660 to 690V AC 50/60 Hz AC-3), 5.5 kW (at 400V AC 50/60 Hz AC-4), 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 11 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 415 to 440V AC 50/60 Hz AC-3e), 15 kW (at 500V AC 50/60 Hz AC-3e), 15 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Electrical Durability | 1.65 Mcycles (25 A, AC-3, Less than 440 V); 1.4 Mcycles (40 A, AC-1, Less than 440 V); 1.65 Mcycles (25 A, AC-3e, Less than 440 V) |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Non-Overlap Time | 1.5 ms |
Signalling Circuit Frequency | 25 to 400 Hz |
Operating Speed | 3600 cycles per hr |
Switching Voltage | 17 V (Signalling Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Overvoltage Category | CAT III |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit) |
IP Rating | IP20 |
Terminal Connection Type | Screw Clamp Terminals |
Full Load Current - Resistive | 40 A |
Frequency | 50/60 Hz |
NEMA Enclosure Rating | No Enclosure |
Maximum Voltage Rating | 690V AC |
Resistance Properties | Fire Resistant, Insulation Resistant |
Horsepower @ Single Phase - 240V AC | 3 hp |
Full Load Current - Inductive | 25 A |
NEMA Enclosure Material | Not Applicable |
Horsepower @ Three Phase - 600V AC | 20 hp |
Coil Voltage | 120V AC |
Horsepower @ Single Phase - 120V AC | 2 hp |
Number of Normally Open Main Contacts | 3 |
Horsepower @ Three Phase - 240V AC | 7 1/2 hp |
Mechanical Operating Durability | 15,000,000 |
Reversing Capability | Non-Reversing |
Includes Auxiliary Contacts | Yes |
Minimum Operating Temperature | -40 Degrees F |
Embedded Surge Suppressor | No |
Electrical Operating Durability | 1,400,000, 1,650,000 |
Number of Auxillary Contacts | 2 |
Mounting Style | DIN Rail, Plate |
Phase | Three |
Contactor Style | IEC |
Maximum Operating Temperature | 140 Degrees F |
Horsepower @ Three Phase - 480V AC | 15 hp |
Horsepower @ Three Phase - 208V AC | 7 1/2 hp |
Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1; Power circuit 600 V CSA; Power circuit 600 V UL; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL |
Rated Short Time Withstand Current | 240 A 104°F (40°C) - 10 s for power circuit; 380 A 104°F (40°C) - 1 s for power circuit; 50 A 104°F (40°C) - 10 min for power circuit; 120 A 104°F (40°C) - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
Poles Description | 3P |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Mounting Support | Rail; Plate |
Pollution Degree | 3 |
Control Circuit Type | AC 50/60 Hz |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 8 Gn for 11 ms) |
Average Impedance | 2 mOhm - Ith 40 A 50 Hz for power circuit |
Hold-In Power Consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)); 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |
Connections - Terminals | Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (2.5 to 10 mm²) - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.02 in² (2.5 to 10 mm²) - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (1 to 10 mm²) - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 6 mm²) - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (1.5 to 10 mm²) - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.02 in² (2.5 to 10 mm²) - cable stiffness: solid without cable end |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Rated Operational Current | 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
Maximum Horse Power Rating | 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 2 hp at 115 V AC 50/60 Hz for 1 phase motors; 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors; 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Product Certifications | UL; BV; RINA; GOST; DNV; LROS (Lloyds register of shipping); CCC; GL; CSA; UKCA |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Contactor Application | Motor control; Resistive load |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Inrush Power in VA | 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
Flame Retardance | V1 conforming to UL 94 |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 450 A at 440 V for power circuit conforming to IEC 60947 |
Control Circuit Voltage | 120 V AC 50/60 Hz |
IP Degree Of Protection | IP20 front face IEC 60529 |
Power Dissipation Per Pole | 3.2 W AC-1; 1.25 W AC-3; 1.25 W AC-3e |
Contact Compatibility | M2 |
Minimum Switching Voltage | 17 V for signalling circuit |
Product Or Component Type | Contactor |
Minimum Switching Current | 5 mA for signalling circuit |
Protective Cover | With |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1 |
Auxiliary Contact Composition | 1 NO + 1 NC |
Compatibility Code | LC1D |
Pole Contact Composition | 3 NO |
Climatic Withstand | IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit; 40 A (at 140°F (60°C)) for power circuit |
Protective Treatment | THIEC 60068-2-30 |
Heat Dissipation | 2 to 3 W at 50/60 Hz |
Permissible Ambient Air Temperature Around The Device | -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Utilisation Category | AC-3; AC-4; AC-1; AC-3e |
Motor Power KW | 5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3); 11 kW at 380 to 400 V AC 50/60 Hz (AC-3); 11 kW at 415 to 440 V AC 50/60 Hz (AC-3); 15 kW at 500 V AC 50/60 Hz (AC-3); 15 kW at 660 to 690 V AC 50/60 Hz (AC-3); 5.5 kW at 400 V AC 50/60 Hz (AC-4); 5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e); 11 kW at 380 to 400 V AC 50/60 Hz (AC-3e); 11 kW at 415 to 440 V AC 50/60 Hz (AC-3e); 15 kW at 500 V AC 50/60 Hz (AC-3e); 15 kW at 660 to 690 V AC 50/60 Hz (AC-3e) |
Description
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 3, Full Load Current - Inductive 25 A, Full Load Current - Resistive 40 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
Explore More Products
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 3 Poles, 48 to 130 V AC/DC, 40 A, Reversing: No LC1D40AEHE
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 3 Poles, 24 V AC, 80 A, Reversing: No LC1D80B7
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 3 Poles, 24 V AC, 9 A, Reversing: Yes LC2D099B7
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 3 Poles, 24 V AC, 25 A, Reversing: Yes LC2D25B7V
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 4 Poles, 240 V AC, 20 A LC1DT20U7
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 3 Poles, 100 to 250 V AC/DC, 25 A, Reversing: No LC1D25KUE
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 3 Poles, 125 V DC, 9 A LC1D09GD
- SCHNEIDER ELECTRIC Contactor, 24-48V AC/DC, 50/60 Hz LC1G1504BEEA
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 3 Poles, 24 V DC, 18 A LC1D186BL
- EATON IEC Magnetic Contactor, 3 Poles, 208 V AC, 95 A, Reversing: No XTCE095F00E
- EATON IEC Magnetic Contactor, 4 Poles, 24 V AC, 18 A, Reversing: No XTCF032C10T
- Schneider Electric IEC Magnetic Contactors