Item
|
Push Button Control Station
|
Contact Form
|
1NO/1NC
|
Basic Material
|
polycarbonate
|
Legend
|
Start/Stop
|
Type of Operator
|
Push Button
|
Number of Operators
|
2
|
NEMA Rating
|
13, 4X
|
Contact Rating
|
10A @ 600V AC, 2.5A @ 24V DC
|
Housing Color
|
light grey RAL 7035)
|
Standards
|
UL 508 CSA || UL Listed
|
Action
|
Momentary / Momentary
|
Mechanical Interlock
|
No
|
NEMA Contact Rating Designation
|
A600/Q600
|
Operator Color
|
Green/Red
|
Enclosure Material
|
Polycarbonate
|
Green Environmental Attribute
|
RoHS 2011/65/EU Compliant
|
IP Rating
|
65
|
Enclosure Color
|
Light Gray and Dark Gray
|
Voltage
|
600 V
|
Cable Entry
|
2 knock-outs for cable entry 14-14 mm || 2 knock-outs for Pg 13 cable gland and ISO M20 12-12 mm
|
Terminal Connection
|
screw clamp terminal
|
Application
|
Start-Stop function
|
Marking Location
|
Marking on legend holder
|
Contacts Material
|
Silver alloy (Ag/Ni)
|
Shape Of Screw Head
|
Cross Philips no 1; Cross pozidriv No 1; Slotted flat 4 mm; Slotted flat 5.5 mm
|
Product Or Component Type
|
Complete control station
|
Control Station Composition
|
1 flush push-button, green 1 NO START; 1 flush push-button, red 1 NC STOP
|
Operator Profile
|
2 flush push-buttons
|
Mechanical Durability
|
5000000 cycles
|
Rated Insulation Voltage
|
600 V 3)EN/IEC 60947-1
|
Tightening Torque
|
7.08 to 10.62 lbf.in (0.8 to 1.2 N.m) EN/IEC 60947-1
|
Cover Color
|
Dark Gray RAL 7016)
|
Enclosure Base Cover
|
Light Gray RAL 7035)
|
Electrical Durability
|
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C; 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C; 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
|
IP Degree Of Protection
|
IP66 IEC 60529; IP67; IP69; IP69K
|
Ambient Air Temperature For Operation
|
-40 to 158°F (-40 to 70°C)
|
Overvoltage Category
|
Class II IEC 60536
|
Rated Operational Current
|
6 A 120 V, AC-15, A600 EN/IEC 60947-5-1; 3 A 240 V, AC-15, A600 EN/IEC 60947-5-1; 1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1; 0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1; 0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1; 0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1
|
Short-Circuit Protection
|
10 A cartridge fuse gG EN/IEC 60947-5-1
|
NEMA Degree Of Protection
|
NEMA 13; NEMA 4X
|
Rated Impulse Withstand Voltage
|
6 kV EN/IEC 60947-1
|
Operating Travel
|
0.06 in (1.5 mm) NC changing electrical state); 0.10 in (2.6 mm) NO changing electrical state); 0.17 in (4.3 mm) total travel)
|
IK Degree Of Protection
|
IK03 EN 50102
|
Conventional Free Air Thermal Current
|
10 A EN/IEC 60947-5-1
|
Protective Treatment
|
TH
|
Connections - Terminals
|
Screw clamp terminals, Less than or Equal to 2 x 1.5 mm² with cable end EN/IEC 60947-1; Screw clamp terminals, Greater than or Equal to 1 x 0.22 mm² without cable end EN/IEC 60947-1
|
Electrical Reliability
|
Less than 10exp(-6) 5 V, 1 mA EN/IEC 60947-5-4; Less than 10exp(-8) 17 V, 5 mA EN/IEC 60947-5-4
|
Shock Resistance
|
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27; 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
|
Product Certifications
|
CSA; UL Listed
|
Product Destination
|
For XB5 22 mm control and signalling units
|
Vibration Resistance
|
5 gn 12 to 500 Hz)IEC 60068-2-6
|
Positive Opening
|
With EN/IEC 60947-5-1 appendix K
|
Operating Force
|
3.5 N NC changing electrical state; 3.8 N NO changing electrical state
|
Ambient Air Temperature For Storage
|
-40 to 158°F (-40 to 70°C)
|
Contact Operation
|
Slow-break
|
Resistance To High Pressure Washer
|
1015.26 psi (7000000 Pa) 131°F (55°C) 0.1 m
|