- Home
- /
- Electrical Supplies
- /
- Industrial Control & Automation
- /
- Motor Controls
- /
- Contactors & Contacts
- /
- IEC Magnetic Contactors
- /
- Miniature IEC Magnetic Contactor, 3 Poles, 24 V DC, 9 A, Reversing: No
Square D
Miniature IEC Magnetic Contactor, 3 Poles, 24 V DC, 9 A, Reversing: No
Mfr # LP1K0910BD
Zoro # G2600132
Free Shipping & Returns
$93.45
Item successfully saved to ''
Free Shipping on orders over $50
after youÂ
Free 30-Day Returns
Key Features
- Action Non-Reversing
- Full Load Amps-Inductive 9 A
- Full Load Amps-Resistive 20 A
- Number of Poles 3
- Coil Volts 24 V DC
Customers Also Purchased
- Brand Square D
-
MFR #
LP1K0910BD
-
Zoro #
G2600132
- UPC # 785901832485
- Country of Origin France
- Category IEC Magnetic Contactors
Dimensions
Height | 1.77 in |
Width | 1.77 in |
Depth | 2.24 in |
NEMA Size | Not Applicable |
Working Height | 6561.68 ft |
Overall Depth | 2.24 in |
Overall Width | 1.77 in |
Overall Height | 2.28 in |
Details
Item | Miniature IEC Magnetic Contactor |
Action | Non-Reversing |
Full Load Amps-Inductive | 9 A |
Full Load Amps-Resistive | 20 A |
Number of Poles | 3 |
Coil Volts | 24 V DC |
Reversing | No |
HP @ 1 Phase - 230V | 1-1/2 |
HP @ 1 Phase - 120V | 1/2 hp |
HP @ 1 Phase - 240V | 1 1/2 hp |
HP @ 3 Phase - 208V | 2 hp |
HP @ 3 Phase - 240V | 3 hp |
HP @ 3 Phase - 480V | 5 hp |
HP @ 3 Phase - 575V | 5 hp |
Aux. Contact Configuration | 1NO |
Enclosure NEMA Rating | No Enclosure |
Hz | 50/60 |
Auxiliary Contact Form | 1NO |
Standards | CSA, UKCA, UL Listed |
Frame / Series / Class / Code | TeSys |
Series | TeSys K |
Rated Insulation Volts | 600/690V |
Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
Switching Voltage | 17 V (Signalling Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Mechanical Durability | 10 Mcycles |
Net Weight | 0.225 kg |
Electrical Durability | 1.3 Mcycles 9 A AC-3 Less than or Equal to 440 V; 1.3 Mcycles 9 A AC-3e Less than or Equal to 440 V; 0.16 Mcycles 20 A AC-1 Less than or Equal to 690 V; 0.02 Mcycles 54 A AC-4 Less than or Equal to 440 V |
Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.1 to 0.75 Uc (at 50°C) |
Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
Rated Voltage | 690V AC |
Rated Making Capacity | 110 A |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Tightening Torque | 0.8 to 1.3 Nm |
Impedance | 3 mOhm |
Rated Breaking Capacity | 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V |
Mounts On | Plate, Rail |
Application | Motor Control, Resistive Load |
Operating Speed | 3600 cycles per hr |
Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
Overvoltage Category | CAT III |
Operating Time | 30 to 40 ms (Coil Energisation and NO Closing), 10 ms (Coil De-Energisation and NO Opening) |
Impulse Withstand Voltage | 8 kV |
Number of Auxillary Contacts | 1 |
NEMA Enclosure Rating | No Enclosure |
Frequency | 50/60 Hz |
Number of Normally Open Main Contacts | 3 |
Full Load Current - Inductive | 9 A |
Maximum Voltage Rating | 690V AC |
Maximum Operating Temperature | 122 Degrees F |
Embedded Surge Suppressor | No |
Horsepower @ Three Phase - 600V AC | 5 hp |
Horsepower @ Three Phase - 240V AC | 3 hp |
Includes Auxiliary Contacts | Yes |
Horsepower @ Single Phase - 240V AC | 1 1/2 hp |
Full Load Current - Resistive | 20 A |
Terminal Connection Type | Screw Clamp Terminals |
NEMA Enclosure Material | Not Applicable |
Horsepower @ Three Phase - 480V AC | 5 hp |
Mechanical Operating Durability | 10,000,000 |
Minimum Operating Temperature | -13 Degrees F |
Mounting Style | DIN Rail, Plate |
Coil Voltage | 24V DC |
Resistance Properties | Insulation Resistant |
Contactor Style | IEC |
Horsepower @ Three Phase - 208V AC | 2 hp |
Horsepower @ Single Phase - 120V AC | 1/2 hp |
Reversing Capability | Non-Reversing |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz |
Mounting Support | Rail; Plate |
Rated Short Time Withstand Current | 90 A 122°F (50°C) - 1 s for power circuit; 85 A 122°F (50°C) - 5 s for power circuit; 80 A 122°F (50°C) - 10 s for power circuit; 60 A 122°F (50°C) - 30 s for power circuit; 45 A 122°F (50°C) - 1 min for power circuit; 40 A 122°F (50°C) - 3 min for power circuit; 20 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit |
Maximum Operating Rate | 3600 cyc/h |
Flame Retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
Poles Description | 3P |
Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Auxiliary Contact Composition | 1 NO |
Control Circuit Type | DC standard |
Ambient Air Temperature For Operation | -13 to 122°F (-25 to 50°C) |
Minimum Switching Current | 5 mA for signalling circuit |
Contactor Application | Motor control; Resistive load |
Associated Fuse Rating | 25 A gG at Less than or Equal to 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947; 10 A gG for signalling circuit conforming to VDE 0660 |
Operating Altitude | 6561.68 ft (2000 m) without derating |
Hold-In Power Consumption in W | 3 W 68°F (20°C) |
IRMS Rated Making Capacity | 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
Product Certifications | CB Scheme; CCC; UL; CSA; EAC; CE; UKCA |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Inrush Power in W | 3 W 68°F (20°C)) |
Utilisation Category | AC-3; AC-3e; AC-1; AC-4 |
Ambient Air Temperature For Storage | -58 to 176°F (-50 to 80°C) |
Motor Power KW | 2.2 kW 220 to 230 V AC 50/60 Hz AC-3; 4 kW 380 to 415 V AC 50/60 Hz AC-3; 4 kW 440/690 V AC 50/60 Hz AC-3; 2.2 kW 220 to 230 V AC 50/60 Hz AC-3e; 4 kW 380 to 415 V AC 50/60 Hz AC-3e; 4 kW 440/690 V AC 50/60 Hz AC-3e; 2.2 kW 220 to 230 V AC 50/60 Hz AC-4; 4 kW 380 to 415 V AC 50/60 Hz AC-4; 4 kW 440/690 V AC 50/60 Hz AC-4 |
Power Pole Contact Composition | 3 NO |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Connections - Terminals | screw clamp terminals 1 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 1 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.00 in² (0.34 to 2.5 mm²)flexible with cable end; screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 2 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 2 0.00 to 0.00 in² (0.34 to 1.5 mm²)flexible with cable end; Power circuit screw clamp terminals 2 0.00 in² (1.5 mm²)flexible with cable end |
Rated Operational Current | 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit |
Rated Insulation Voltage | Power circuit 600 V UL 508; Power circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-5-1; Signalling circuit 600 V UL 508; Power circuit 600 V CSA C22.2 No 14; Signalling circuit 600 V CSA C22.2 No 14 |
Auxiliary Contacts Type | Instantaneous 1 NO |
Conventional Free Air Thermal Current | 20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit |
IP Degree Of Protection | IP2X |
Heat Dissipation | 1.3 W |
Product Or Component Type | Contactor |
Minimum Switching Voltage | 17 V for signalling circuit |
Description
Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 2.28 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC
Explore More Products
- SQUARE D IEC Magnetic Contactor, 3 Poles, 24 V DC, 25 A, Reversing: No LC1D25BD
- SQUARE D IEC Magnetic Contactor, 3 Poles, 24 V DC, 25 A, Reversing: Yes LC2D25BD
- SQUARE D IEC Magnetic Contactor, 3 Poles, 24 V DC, 12 A, Reversing: Yes LC2D12BD
- SQUARE D IEC Magnetic Contactor, 3 Poles, 24 V AC, 115 A, Reversing: No LC1D115B7
- SQUARE D IEC Magnetic Contactor, 3 Poles, 480 V AC, 150 A, Reversing: No LC1D150T7
- SQUARE D IEC Magnetic Contactor, 3 Poles, 24 V DC, 115 A, Reversing: No LC1D115BD
- SQUARE D IEC Magnetic Contactor, 3 Poles, 24 V AC, 150 A, Reversing: No LC1D150B7
- SQUARE D IEC Magnetic Contactor, 3 Poles, 24 V DC, 18 A, Reversing: Yes LC2D18BD
- SQUARE D IEC Magnetic Contactor, 3 Poles, 24 V AC, 32 A, Reversing: Yes LC2D32B7
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 3 Poles, 220 V AC, 18 A, Reversing: No LC1D18M7
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 4 Poles, 24 V DC, 20 A LC1DT20BL
- Square D Motor Controls