Output Load Reactors (36 items)
Relevance
KDR-LINE REACTORS
Key Features:
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Standards: RoHS, UL Listed
- Enclosure: Open
KDR-LINE REACTORS
Key Features:
- Watts Loss: 105 W
- Height: 6
- Width: 7.2
KDR-LINE REACTORS
Key Features:
- Width: 9
- Filter Type: Ultra Low Z
- Impedance: 1.5 %
KDR-LINE REACTORS
Key Features:
- Depth: 4.25
- Max. Output Amps: 17 A
- Impedance: 1.5 %
KDR-LINE REACTORS
Key Features:
- Features: Protects 6-Pulse Rectifiers and Power Conversion Devices, Protects the Drive from Harmful Voltage Spikes, Reduces Harmonics
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Max. Output Amps: 180 A
KDR-LINE REACTORS
Key Features:
- Filter Type: Ultra Low Z
- Max. Output Amps: 77 A
- Depth: 6
KDR-LINE REACTORS
Key Features:
- Item: Output Reactor
- Depth: 11
- Impedance: 1.5 %
KDR-LINE REACTORS
Key Features:
- Function: Reduce Voltage Overshoots and Reflective Wave Due to dV/dT
- Depth: 7.5
- Input Voltage: 575V AC
KDR-LINE REACTORS
Key Features:
- Function: Reduce Voltage Overshoots and Reflective Wave Due to dV/dT
- Filter Type: Ultra Low Z
- Height: 5.75
KDR-LINE REACTORS
Key Features:
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Enclosure: Open
- Depth: 9.75
KDR-LINE REACTORS
Key Features:
- Max. HP: 75 hp
- Item: Output Reactor
- Phase: Three
KDR-LINE REACTORS
Key Features:
- Depth: 4.25
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Standards: UL Listed
KDR-LINE REACTORS
Key Features:
- Max. Output Amps: 99 A
- Phase: Three
- Max. HP: 100 hp
KDR-LINE REACTORS
Key Features:
- Input Voltage: 575V AC
- Standards: UL Listed
- Max. HP: 25 hp
KDR-LINE REACTORS
Key Features:
- Width: 11
- Watts Loss: 280 W
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
KDR-LINE REACTORS
Key Features:
- Input Voltage: 480V AC
- Standards: UL Listed
- Features: Protects 6-Pulse Rectifiers and Power Conversion Devices, Protects the Drive from Harmful Voltage Spikes, Reduces Harmonics
KDR-LINE REACTORS
Key Features:
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Watts Loss: 123 W
- Max. Output Amps: 52 A
KDR-LINE REACTORS
Key Features:
- Depth: 9.31
- Impedance: 1.5 %
- Enclosure: Open
KDR-LINE REACTORS
Key Features:
- Width: 15
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Impedance: 1.5 %
KDR-LINE REACTORS
Key Features:
- Height: 9
- Features: Protects 6-Pulse Rectifiers and Power Conversion
- Filter Type: Ultra Low Z
KDR-LINE REACTORS
Key Features:
- Phase: Three
- Enclosure: Open
- Filter Type: Ultra Low Z
KDR-LINE REACTORS
Key Features:
- Features: Protects 6-Pulse Rectifiers and Power Conversion
- Phase: Three
- Function: Reduce Voltage Overshoots and Reflective Wave Due to dV/dT
KDR-LINE REACTORS
Key Features:
- Standards: RoHS, UL Listed
- Watts Loss: 465 W
- Filter Type: Ultra Low Z
KDR-LINE REACTORS
Key Features:
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Filter Type: Ultra Low Z
- Function: Reduce Voltage Overshoots and Reflective Wave Due to dV/dT
KDR-LINE REACTORS
Key Features:
- Filter Type: Ultra Low Z
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Standards: RoHS, UL Listed
KDR-LINE REACTORS
Key Features:
- Filter Type: Ultra Low Z
- Standards: RoHS, UL Listed
- Enclosure: Open
KDR-LINE REACTORS
Key Features:
- Features: Protects 6-Pulse Rectifiers and Power Conversion Devices, Protects the Drive from Harmful Voltage Spikes, Reduces Harmonics
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Watts Loss: 587 W
KDR-LINE REACTORS
Key Features:
- Item: Output Reactor
- Width: 9
- Phase: Three
KDR-LINE REACTORS
Key Features:
- Item: Output Reactor
- Watts Loss: 254 W
- Features: Protects 6-Pulse Rectifiers and Power Conversion Devices, Protects the Drive from Harmful Voltage Spikes, Reduces Harmonics
KDR-LINE REACTORS
Key Features:
- Item: Output Reactor
- Enclosure: Open
- Standards: RoHS, UL Listed
KDR-LINE REACTORS
Key Features:
- Input Voltage: 575V AC
- Max. HP: 450 hp
- Enclosure: Open
KDR-LINE REACTORS
Key Features:
- Height: 9
- Features: Protects 6-Pulse Rectifiers and Power Conversion
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
KDR-LINE REACTORS
Key Features:
- Max. Output Amps: 32 A
- Item: Output Reactor
- Watts Loss: 106 W
KDR-LINE REACTORS
Key Features:
- Phase: Three
- Max. Output Amps: 22 A
- Depth: 4.25
KDR-LINE REACTORS
Key Features:
- Standards: RoHS, UL Listed
- Application: Conveyors, HVAC Chillers, Oil Rigs, Pumps, Sprinkler Irrigation Systems
- Enclosure: Open
KDR-LINE REACTORS
Key Features:
- Item: Output Reactor
- Filter Type: Ultra Low Z
- Impedance: 1.5 %
About Output Load Reactors
Noise spikes (AKA harmonic distortion) can ride on the leading edge of electrical signals from a VFD’s high frequency PWM three-phase output to the motor. An output load reactor serves as a buffer between the VFD and the motor, providing an increase in inductance along the cable run, thereby protecting the electrical motor from those spikes. If the wiring distance between the VFD and the motor is not very long, use an output line reactor instead.