VA Rating - UPS Systems
350.0 VA
Output Voltage
110/115/120V AC
Backup Time (Half/Full Load)
7 min/2 min
Outlet Type
(3) Surge; (3) UPS/Surge
Green Environmental Attribute
Product Contributes To Reducing Energy Consumption
NEMA Plug Configuration
5-15P
Footnotes
DB9 and TEL/DSL
Special Features
Cold Start Operation Supported
Standards
CSA, CSA-C22.2 No. 107.3, FCC Part 15 Class B, NOM, RoHS, UL1778
Transfer Time
2 to 4 msec
Automatic Volts Regulation
No
NEMA Receptacle Configuration
(6) 5-15R
Fax/Modem Line Protection
Yes
Operating Temp. Range
122°F (50°C)
Battery Type
Sealed Lead Acid (SLA)
Capacity - Batteries
350 VA/180 W
Input Connection
NEMA 5-15P Plug
Nominal Input Voltage(s) Supported
120V AC
Individually Controllable Load Banks
No
High Availability UPS Features
Battery Independent Restart
Low Voltage Transfer to Battery Power (Setpoint)
95
Communications Interface
DB9 Serial
UPS AC Suppression Joule Rating
316
AC Mode BTU / Hr. (Full Load)
13.1
Output Voltage Regulation (Line Mode)
120V (±20%)
Recommended Electrical Service
15A 120V
PowerAlert Software
For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Half Load Runtime (min.)
7 min. (105w)
Full Load Runtime (min.)
2 min. (210w)
Primary Form Factor
Desktop
Audible Alarm
UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace-battery conditions
Battery Replacement Description
Replaceable internal batteries (see manual)
High Voltage Transfer to Battery Power (Setpoint)
145
Operating Elevation (ft.)
Up to 10,000 ft.
DC System Voltage (VDC)
12
Rated input current (Maximum Load)
5A
Battery Recharge Rate (Included Batteries)
6.5 hours (10% to 90%)
AC Mode Efficiency Rating (100% Load)
>98%
Storage Temperature Range
+5 to +113 degrees Fahrenheit / -15 to +45 degrees Celsius
Switches
Switch controls power off/on status
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)
UPS AC Suppression Response Time
Instantaneous
EMI / RFI AC Noise Suppression
Yes
Input Circuit Breakers
5A
Cold Start (Startup in Battery Mode During a Power Failure)
Cold-start operation supported
WatchDog Compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
Communications Cable
DB9 serial interface cable included
UPS Certification Details
UL1778: 2014 5th EDITION; CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; FCC CLASS B; FCC Part 68 Approved (#5WSWP01B005); Industry Canada Approved (#3449A-005, REN0.1B); RETIE (Colombia)
Installation Form Factors Supported with Included Accessories
Tower; Ultra-compact desktop; Wallmount
Output Watt Capacity (Watts)
210
UPS Dataline Suppression
1 line TEL/DSL or Ethernet
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Operating Elevation (m)
Up to 3000m
Relative Humidity
0 to 90%, non-condensing
Nominal Output Voltage(s) Supported
110V; 115V; 120V
Output Voltage Regulation (Battery Mode)
120V (±10%)
Output Volt Amp Capacity (VA)
350
Battery Access
Battery access door
LED Indicators
1 Status LED reports operating mode and fault status
Output AC Waveform (Battery Mode)
PWM sine wave
Package Contents
Internet Office INTERNET350SER 350VA UPS, INTERNET350SER standby UPS system, DB9 Serial Cable for use with PowerAlert UPS monitoring software, Instruction manual and warranty information
Software Included
PowerAlert UPS monitoring software
Battery Chemistry
Valve Regulated Lead Acid
Additional Information
Low voltage transfer to battery power: approx. 100VAC, High voltage transfer to battery power: approx. 141VAC, Cold Start: Inverter can be "cold started" to enable temporary AC output during a power failure
Form Factor
Ultra-compact Desk-mount
Status Indicators
Line Power, Battery Power Status
Typical Battery Recharge Time
4 Hour
Maximum Operating Temperature
122°F (50°C)
Dataline Protection
RJ-11
Load Capacity
350 VA/180 W
Waveform Type
Pulse-width Modulated Sine Wave
Surge Energy Rating
316 J
UPS Applications
Computer/Peripherals; Retail/Point of Sale; Hospitality
Package Includes
INTERNET350SER 350VA 210W 120V Standby UPS with 6 Outlets;DB9 serial interface cable;Owner's manual
Product Compliance
FCC Part 15 Class B (USA)
Product Certifications
RETIE (Colombia); CSA (Canada); CAN/CSA-C22.2 No. 107.3 (Canada); NOM (Mexico); UL 1778
Output Capacity (Watts)
210
Surge Suppression Rating
316 J
Automatic Voltage Regulation
No Automatic Voltage Regulation
Data Line Protection
Includes Data Line Surge Protection
Run Time - Full Load
2 min
External Battery Compatible
Not External Battery Pack Compatible
Battery Recharge Time
6.5 hr
Transfer Time - Minimum
6 msec
Number of Outlets - UPS
3
Number of Outlets - Surge Only
3
Power Rating - Real
210 W
Transfer Time - Maximum
10 msec
Receptacle Configuration
5-15R
Manufacturer Warranty
3 yr Limited
Visible Indicator Light Conditions
Fault
Operating Temperature - Maximum
104 Degrees F
Output Ports Included
DB9 Serial
Power Rating - Apparent
350 VA
Audible Alarm Conditions
Low Battery, Overload, Replace Battery
Operating Temperature - Minimum
32 Degrees F
Includes Battery
Battery Included
Input Current - Maximum
5 A