- MFR #
- FLUKE-287/CWG
- Zoro #
- G8039236
- UPC #
- -
- Country of Origin
- United States
- Item
- Digital Multimeter
- Display Type
- Dot Matrix
- Data Hold
- Yes
- Instrument Counts
- 50,000
- Includes
- Alligator Clips (AC175 ), Test Leads (TL71), (6) Batteries
- Standards
- CE, CSA, UL
- Auto Power Off
- Yes
- Data Logging
- Yes
- Audible Continuity
- Yes
- Diode Test
- Yes
- Capacitance Range
- 0.001 nF to 100 mF
- Instrument Frequency Counter Range
- 0.01 Hz to 1 MHz
- Duty Cycle
- Duty Cycle Test Included
- Calibration Certificate Included
- Traceable without Data
- AC Response
- TRMS
- Temp. Range
- -328 Degrees to 1994 Degrees F
- Max. DC Amps
- 10 A
- Peak Hold
- Yes
- Max. AC Amps
- 10:00 AM
- Basic DC Accuracy
- +/-0.025% of Reading +2 Digits
- NIST Certification By
- Techni-Tool
- Instrument Safety Rating
- CAT III 1000V, CAT IV 600V
- Auto Ranging
- Yes
- Series
- FLUKE (R) Fluke-287
- Display
- Backlit Digital - 1/4 VGA Dot Matrix
- Multimeter Style
- Full Size - Advanced Features
- Max. Ohms
- 500 megohm
- Interface
- USB
- Intrinsically Safe
- No
- Batteries Included
- Yes
- Time of Day Clock
- Yes
- Minimum Resistance Measurement
- 50 ohm
- Maximum AC Voltage Measurement
- 1,000 V
- Frequency Measurement Resolution
- 0.01 Hz
- Computer Interface Connection Type
- USB
- Basic DC Voltage Accuracy
- +/-0.025% + 2 Digits
- Minimum DC Voltage Measurement
- 0 V
- Dustproof
- No
- Weight
- 28 oz
- Bar Graph Included
- Yes
- Maximum Storage Temperature
- 140 Degrees F
- Battery Chemistry
- Alkaline
- Elapse Time Clock
- Yes
- Bluetooth Compatible
- Yes
- Minimum/Maximum Memory
- Min/Max
- Waterproof
- No
- Maximum Operating Temperature
- 131 Degrees F
- Resistance Measurement Accuracy
- +/-0.05%
- Thermal Imaging
- No
- Minimum Storage Temperature
- -40 Degrees F
- Minimum DC Current Measurement
- 0 A
- Maximum Temperature Measurement
- 1,994 Degrees F
- Temperature Measurement Accuracy
- 1.00 %
- Software Included
- No
- Capacitance Measurement Accuracy
- 1.00 %
- Minimum Temperature Measurement
- -328 Degrees F
- AC Response Calculation
- TRMS
- Current Leakage Testing
- No
- Maximum Capacitance Measurement
- 100 mF
- Removable Screen
- No
- Maximum DC Current Measurement
- 10 A
- Basic DC Current Accuracy
- +/-0.05%
- Basic AC Voltage Accuracy
- +/-0.4%
- Basic AC Current Accuracy
- +/-0.6%
- Min-Max-Avg Button Included
- Yes
- Minimum Frequency Measurement
- 0.01 Hz
- Fuse Access
- Yes
- Minimum Operating Temperature
- -4 Degrees F
- Maximum Frequency Measurement
- 1 MHz
- Battery Access
- Yes
- Maximum AC Current Measurement
- 10 A
- Minimum AC Current Measurement
- 0 A
- Minimum AC Voltage Measurement
- 0 V
- Multiple On-Screen Displays
- Yes
- Minimum Capacitance Measurement
- 0 nF
- NIST Certification By Manufacturer
- Techni-Tool
- Frequency Measurement Accuracy
- 0.005 %
- Maximum Resistance Measurement
- 500 megaohm
- Capacitance Measurement Resolution
- 0 nF
- Parameters Measured
- AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature
- Maximum DC Voltage Measurement
- 1,000 V
- Current Units
- A, mA
- IP Rating
- Not Rated
- Battery Voltage
- 1.5 V
- Includes Auto Sensing
- No Auto Sensing Included
- Temperature Types Measured
- Temperature Degrees C, Temperature Degrees F
- Data Output Type
- USB
- Special Features
- Trend Capture Plots Measurements as Single Line to Help Detect Anomalies
- CAT Safety Rating
- CAT III 1000V, CAT IV 600V