- Item
- Digital Pressure Sensor
- Range
- 0 to 14.5 psi
- Power Required
- 18 to 30V DC
- Process Connection
- 1/4 in NPT
- Electrical Connection
- 4-Pin M12 Male Connector
- Display
- Display unit 4 x LED, green (mbar, psi, kPa, inHg) switching status 2 x LED, yellow measured values alphanumeric display, red/green 4-digit
- IP Rating
- IP65, IP67
- Off Set Point
- 0.05 to 14.45 psi
- Contact Form
- 1NO/1NC
- Wetted Materials
- Ceramic, Stainless Steel
- Housing Material
- Stainless Steel
- Circuit Type
- PNP/NPN
- Temp. Range
- -13 Degrees to 176 Degrees F
- Burst Pressure
- 450 psi
- On Set Point
- 0.1 to 14.5 psi
- Compatible With
- Air and Liquids
- Output Current
- 150mA, 200mA @ 60 Degrees C, 250mA @ 40 Degrees C
- Application
- for industrial applications
- Series
- PN
- Product Type
- Digital Pressure Sensor
- Storage temperature [°C]
- -40...100
- MTTF [years]
- 260
- Hysteresis deviation [% of the span]
- <± 0,25
- In steps of
- 1 mbar 0.01 psi 0.1 inHg 0.1 kPa, 5 mbar 0.05 psi 0.1 inHg 0.5 kPa
- Repeatability [% of the span]
- <± 0,1; (with temperature fluctuations < 10 K)
- Electrical design
- PNP/NPN
- Materials (wetted parts)
- stainless steel (1.4404 / 316L); ceramics; FKM
- Min. insulation resistance [MΩ]
- 100; (500 V DC)
- Reverse polarity protection
- yes
- Materials
- stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
- Short-circuit protection
- yes
- MAWP (for applications according to CRN)
- 10 bar 10000 mbar 145 psi 290 inHg 1000 kPa
- Min. difference between SP and rP
- 5 mbar 0.08 psi 0.2 inHg 0.5 kPa, 5 mbar 0.1 psi 0.2 inHg 0.5 kPa
- Profiles
- Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000), Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
- Output function
- normally open / normally closed; (parameterisable)
- Power-on delay time [s]
- < 0.3
- Communication interface
- IO-Link
- Output signal
- switching signal; IO-Link; (configurable)
- Long-term stability [% of the span]
- <± 0,05; (per 6 months)
- Shock resistance
- DIN EN 60068-2-27 50 g (11 ms)
- Parameter setting options
- hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit
- Overload protection
- yes
- SDCI standard
- IEC 61131-9
- Transmission type
- COM2 (38,4 kBaud)
- Total number of outputs
- 2
- SIO mode
- yes
- Ambient temperature [°C]
- -25...80
- Reset point rP
- 3...995 mbar 0.05...14.43 psi 0.1...29.4 inHg 0.3...99.5 kPa, 5...995 mbar 0.05...14.45 psi 0.1...29.4 inHg 0.5...99.5 kPa
- Response time [ms]
- < 3
- Max. voltage drop switching output DC [V]
- 2.5
- Characteristics deviation [% of the span]
- <± 0,25 (BFSL) / <± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
- Required master port type
- A; (when pin 2 not connected: B)
- IO-Link resolution pressure [MPa]
- 0.0005, 0.001
- Operating voltage [V]
- 18...30 DC; (to SELV/PELV)
- Number of inputs and outputs
- Number of digital outputs: 2
- Current consumption [mA]
- < 35
- Number of digital outputs
- 2
- Special feature
- Gold-plated contacts
- Set point SP
- 10...1000 mbar 0.1...14.5 psi 0.2...29.5 inHg 1...100 kPa, 8...1000 mbar 0.12...14.5 psi 0.2...29.5 inHg 0.8...100 kPa
- Temperature coefficient span [% of the span / 10 K]
- <± 0,2; (-0...80°C)
- Delay time programmable dS, dr [s]
- 0...50
- UL approval
- UL Approval no. J001
- Restrictor element integrated
- no (can be retrofitted)
- Protection class
- III
- Tightening torque [Nm]
- 2...3 turns after hand-fastening; recommended tightening torque; depends on lubrication, seal and pressure rating
- Type of short-circuit protection
- pulsed
- Measuring element
- ceramic-capacitive pressure measuring cell
- Medium temperature [°C]
- -25...80
- Min. process cycle time [ms]
- 3, 2.3
- Connection
- Connector: 1 x M12; coding: A; Contacts: gold-plated
- Switching frequency DC [Hz]
- < 170
- Media
- liquids and gases
- Measuring range
- 0...1 bar 0...1000 mbar 0...14.5 psi 0...29.5 inHg 0...100 kPa
- Switch point accuracy [% of the span]
- <± 0,5
- IO-Link revision
- 1.1
- Type of pressure
- relative pressure
- Integrated watchdog
- yes
- Permanent current rating of switching output DC [mA]
- 150; (200 (...60°C) 250 (...40°C))
- IO-Link process data (cyclical)
- function bit length pressure 14 binary switching information 2, function bit length pressure 16 device status 4 binary switching information 2
- IO-Link functions (acyclical)
- application specific tag
- IO-Link resolution pressure [mbar]
- 1, 0.5
- Vibration resistance
- DIN EN 60068-2-6 20 g (10...2000 Hz)
- Pressure rating
- 10000 mbar 145 psi 290 inHg 1000 kPa
- Temperature coefficient zero point [% of the span / 10 K]
- <± 0,2; (-0...80°C)
- Protection
- IP 65; IP 67
- Pressure Equipment Directive
- Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
- Min. bursting pressure
- 30000 mbar 450 psi 880 inHg 3000 kPa
- Min. pressure cycles
- 100 million
- EMC
- DIN EN 61000-6-2 DIN EN 61000-6-3
- Electrical Design Output
- PNP/NPN
- Voltage Rating - Maximum
- 30 V DC
- Reset Point - Minimum
- 0.05 psi
- Pressure - Maximum
- 14.5 psi
- Pressure - Minimum
- 0 psi
- Operating Temperature - Minimum
- -13 Degrees F
- Operating Temperature - Maximum
- 176 Degrees F
- Pressure Connection Type
- 1/4" FNPT
- Set Point - Maximum
- 14.5 psi
- Reset Point - Maximum
- 14.45 psi
- Set Point - Minimum
- 0.1 psi
- Output Current Rating
- 0.15 A, 0.2 A @ 140 Degrees F, 0.25 A @ 104 Degrees F
- Compatible Media
- Gas, Liquid
- Switch Structure
- SPST
- Switching Signal Output
- PNP/NPN
- Current Rating
- 150 mA, 200 mA, 250 mA