- Item
- Electronic Pressure Sensor
- Range
- -0.2 to 3.6 psi
- Analog Output
- 4 to 20mA or 0 to 10V DC
- Control Output
- PNP
- On/Off Setting
- Programmable
- Max. Pressure
- 450 psi
- Power Required
- 18 to 30V DC
- Process Connection
- 1/4 in NPT
- Electrical Connection
- 4-Pin M12 Male Connector
- Display
- 4 Digit LED
- Operating Temp. Range
- -13 Degrees to 176 Degrees F
- IP Rating
- IP65, IP67
- Standards
- CE, CRN, cULus, DIN EN 60068-2-27, DIN EN 60068-2-6, DIN EN 61000-6-2, DIN EN 61000-6-3, DNV.COM/AF, IEC 61131-9, IO-Link, UKCA
- Housing Material
- PBT, Stainless Steel
- Wetted Materials
- Ceramic, FKM, Stainless Steel
- Application
- for industrial applications
- Number of analogue outputs
- 1
- Analogue end point
- 37.5...250 mbar 15...100.4 inH2O 3.75...25 kPa 385...2550 mmWS
- Total number of outputs
- 2
- IO-Link resolution pressure [mbar]
- 0.1
- Transmission type
- COM2 (38,4 kBaud)
- Max. voltage drop switching output DC [V]
- 2
- MTTF [years]
- 145
- Output signal
- switching signal; analogue signal; IO-Link; (configurable)
- Shock resistance
- DIN EN 60068-2-27 50 g (11 ms)
- Communication interface
- IO-Link
- Integrated watchdog
- yes
- Profiles
- Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000), Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
- Temperature coefficient zero point [% of the span / 10 K]
- <± 0,2; (-0...80°C)
- SIO mode
- yes
- Short-circuit protection
- yes
- Parameter setting options
- hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
- Measuring element
- ceramic-capacitive pressure measuring cell
- Set point SP
- -10.9...250 mbar -4.4...100.4 inH2O -1.09...25 kPa -112...2550 mmWS, -11...250 mbar -4.4...100.4 inH2O -1.1...25 kPa -110...2550 mmWS
- Max. response time analogue output [ms]
- 3
- Type of short-circuit protection
- pulsed
- Min. pressure cycles
- 100 million
- Materials
- stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
- SDCI standard
- IEC 61131-9
- Vacuum resistance [mbar]
- -1000
- Pressure Equipment Directive
- Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
- Protection class
- III
- Switching frequency DC [Hz]
- < 500
- MAWP (for applications according to CRN)
- 10 bar 10000 mbar 4000 inH2O 1000 kPa
- EMC
- DIN EN 61000-6-2 DIN EN 61000-6-3
- Response time [ms]
- < 1.5
- Connection
- Connector: 1 x M12; coding: A; Contacts: gold-plated
- Number of inputs and outputs
- Number of digital outputs: 2; Number of analogue outputs: 1
- Vibration resistance
- DIN EN 60068-2-6 20 g (10...2000 Hz)
- Electrical design
- PNP/NPN
- Damping process value dAP [s]
- 0...4
- Operating voltage [V]
- 18...30 DC; (to SELV/PELV)
- Tightening torque [Nm]
- > 50; (depends on lubrication, seal and pressure rating)
- IO-Link process data (cyclical)
- function bit length pressure 16 device status 4 binary switching information 2, function bit length pressure 14 binary switching information 2
- Delay time programmable dS, dr [s]
- 0...50
- Current consumption [mA]
- < 35
- Special feature
- Gold-plated contacts
- Number of digital outputs
- 2
- Medium temperature [°C]
- -25...80
- Min. load resistance [Ω]
- 2000
- Media
- liquids and gases
- Storage temperature [°C]
- -40...100
- Overload protection
- yes
- Permanent current rating of switching output DC [mA]
- 250
- IO-Link functions (acyclical)
- application specific tag
- Min. bursting pressure
- 30000 mbar 12000 inH2O 3000 kPa 306000 mmWS
- Power-on delay time [s]
- 0.3
- Ambient temperature [°C]
- -25...80
- Required master port type
- A; (when pin 2 not connected: B)
- Type of pressure
- relative pressure
- Materials (wetted parts)
- stainless steel (1.4404 / 316L); AI2O3 (96%; ceramics); FKM
- Reset point rP
- -12...249 mbar -4.8...100 inH2O -1.2...24.9 kPa -122...2539 mmWS, -12...249 mbar -4.8...100 inH2O -1.2...24.9 kPa -120...2540 mmWS
- Analogue start point
- -12.5...200 mbar -5...80.2 inH2O -1.25...20 kPa -125...2040 mmWS
- Switch point accuracy [% of the span]
- <± 0,4; (Turn down 1:1)
- Max. load [Ω]
- 500
- Analogue current output [mA]
- 4...20; (scalable 1:5)
- IO-Link revision
- 1.1
- Repeatability [% of the span]
- <± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
- Reverse polarity protection
- yes
- UL approval
- UL Approval no. J012
- Output function
- normally open / normally closed; (parameterisable)
- Min. process cycle time [ms]
- 2.3, 3
- Damping for the analogue output dAA [s]
- 0...4
- Hysteresis deviation [% of the span]
- <± 0,1; (Turn down 1:1)
- Measuring range
- -0.0125...0.25 bar -12.5...250 mbar -5...100.4 inH2O -1.25...25 kPa -127...2549 mmWS
- Protection
- IP 65; IP 67
- Analogue voltage output [V]
- 0...10; (scalable 1:5)
- Temperature coefficient span [% of the span / 10 K]
- <± 0,2; (-0...80°C)
- Pressure rating
- 10000 mbar 4000 inH2O 1000 kPa 102000 mmWS
- Characteristics deviation [% of the span]
- <± 0,25 (BFSL) / <± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
- Min. insulation resistance [MΩ]
- 100; (500 V DC)
- Min. difference between SP and rP
- 1.1 mbar 0.5 inH2O 0.11 kPa 11 mmWS, 1.5 mbar 0.6 inH2O 0.15 kPa 15 mmWS
- In steps of
- 0.5 mbar 0.2 inH2O 0.05 kPa 5 mmWS, 0.1 mbar 0.1 inH2O 0.01 kPa 1 mmWS
- Restrictor element integrated
- no (can be retrofitted)
- Long-term stability [% of the span]
- <± 0,05; (Turn down 1:1; per 6 months)
- Medium temperature [°C]
- -25...80
- Storage temperature [°C]
- -40...100
- Min. insulation resistance [MΩ]
- 100; (500 V DC)
- Min. load resistance [Ω]
- 2000
- Ambient temperature [°C]
- -25...80
- Max. load [Ω]
- 500
- Voltage Rating - Maximum
- 30 V DC
- Pressure Connection Type
- 1/4" NPT
- Pressure - Minimum
- -0.2 psi
- Pressure - Maximum
- 3.6 psi
- Compatible Media
- Gas, Liquid
- Electrical Design Output
- PNP/NPN
- Series
- PN
- Analog Output Current - Maximum
- 20 mA
- Analog Output Current - Minimum
- 4 mA
- Operating Temperature - Maximum
- 176 Degrees F
- Analog Output Voltage - Maximum
- 10 V DC
- Analog Output Voltage - Minimum
- 0 V DC
- Proof Pressure
- 3,000 kPa
- Operating Temperature - Minimum
- -13 Degrees F
- Analog Signal Output
- 0-10V, 4-20 mA
- Switching Signal Output
- PNP/NPN