- Item
- Electromechanical Timer
- Voltage
- 208 to 277V AC
- Operation Mode
- 25 hour
- Amps
- 40 A
- Time Minimum Setting
- 1 hr.
- Enclosure Type
- Steel
- Indoor/Outdoor Usage
- Indoor/Outdoor
- Min. Time Setting
- 1 hr
- Body Material
- Steel
- Max. Time Setting
- 23 hr
- Contact Form
- DPST
- Max. On/Off Cycles
- 12
- Contact HP @ 120V
- 2 hp
- Contact HP @ 240V
- 5 hp
- Nominal Max. Time Setting
- 24 hr
- Number of Poles
- 2
- Number of Trippers Included
- 2
- Extra Trippers
- 2E054
- Description/Special Features
- 3R Enclosures in Steel or Noncorrosive Plastic, Furnished with a Maximum of 12 Trippers, Manual On/Off Override does not Alter Program, Snap-out Timing Mechanism, Up to 12 On/Off Settings Per Day
- Day Skipper
- No
- Mount
- Hole Wall
- Time Setting Range
- 1 hr. to 23 hr.
- NEMA Rating
- 3R
- Type
- 24-Hour
- Finish
- Metal Enclosure has Gray Enamel
- Standards
- cCSAus, cULus
- Product Type
- Timer
- Wiring Option
- Terminals
- Operating Temperature Max
- 130°C
- Application Compatibilities
- LED; HID
- Timing Interval
- 1 hr
- Number Of Circuits
- 1
- Electronic Ballast Load Ratings
- 16 A, 120 VAC; 16 A, 208 VAC; 16 A, 240 VAC; 16 A, 277 VAC
- Packaging Applications
- Indoor/Outdoor Lighting; Signs; Filters; Electric Fences; Fans; Conveyors; Pool Heaters; Blowers; Pumps
- Operating Temperature Min
- -40°C
- Tungsten Load Ratings
- 40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz
- UL Certification
- cULus
- Maximum On Off Operations
- 12
- Power Consumption Max W
- 3 W
- Input Voltage Ranges
- 208-277 VAC, 60 Hz
- Inductive Load Ratings Ranges
- 40 A, 120-277 VAC, 60 Hz
- Inductive Load Ratings
- 40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz
- CSA Certification
- cCSAus
- Minimum On Off Time
- 1 hour
- UL Cerfication File Number
- UL917
- Pilot Duty Load Ratings Ranges
- 1000 VA, 120-277 VAC, 60 Hz
- Motor Load Ratings
- 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
- Skipper Wheel Operation Mode
- Not Included
- Resistive Load Ratings
- 40 A, 480 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz; 40 A, 347 VAC, 60 Hz
- Resistive Load Ratings Ranges
- 40 A, 120-480 VAC, 60 Hz
- Solutions
- Machinery & Pumps; Panel Integrators
- Electronic Ballast Load Ratings Ranges
- 16 A, 120-277 VAC
- Applications
- Timing/Scheduling ON/OFF; Indoor Lighting Control; Outdoor Lighting Control
- Tungsten Load Ratings Ranges
- 40 A, 120-277 VAC, 60 Hz
- Has Manual Override CVL
- Yes
- Market
- Commercial; Industrial
- Switch Type
- DPST
- Pilot Duty Load Ratings
- 1000 VA, 120 VAC, 60 Hz; 1000 VA, 208 VAC, 60 Hz; 1000 VA, 240 VAC, 60 Hz; 1000 VA, 277 VAC, 60 Hz
- Tungsten Range(s)
- 40 A, 120-277 VAC, 60 Hz
- Features
- Manual Override
- Inductive
- 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz
- Tungsten (NO)
- 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz
- Has Manual Override
- Yes
- Motor Load Ratings Ranges
- 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
- Skipper Wheel
- Not Included
- Operating Temperature Min (°F)
- -40
- Electronic Ballast
- 16 A, 120 VAC, 16 A, 208 VAC, 16 A, 240 VAC, 16 A, 277 VAC
- Maximum Power Consumption (W)
- 3 W
- Maximum ON/OFF Operations
- 12
- Pilot Duty (NO)
- 1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz, 1000 VA, 277 VAC, 60 Hz
- Operating Temperature Max (°F)
- 130
- Resistive
- 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz, 40 A, 347 VAC, 60 Hz, 40 A, 480 VAC, 60 Hz
- Minimum ON/OFF Times
- 1 hour
- Input Voltage Range(s)
- 208-277 VAC, 60 Hz
- Operating Temperature Min (°F)
- -40
- Operating Temperature Max (°F)
- 130
- Series
- T100
- AC Voltage Rating
- 208-277V AC
- On/Off Cycles - Maximum
- 12
- Operating Temperature - Minimum
- -40 Degrees F
- Mounting Style
- Surface
- Application
- Lighting
- Body Color
- Grey
- Time Setting - Maximum
- 24 hr
- Horsepower @ 120V - Maximum
- 2 hp
- Number of Trippers - Maximum
- 2
- Operating Temperature - Maximum
- 130 Degrees F
- Compatible Lighting
- HID, LED
- NEMA Enclosure Rating
- 3R
- Current Rating - Maximum
- 40 A
- Time Setting - Minimum
- 1 hr
- Horsepower @ 240V - Maximum
- 5 hp
- Time Maximum Setting
- 24 hr