Operating temperature
Standard Models: 0 to 55°C (32 to 131°F); Wide Temp. Models: -40 to 75°C (-40 to 167°F); High Voltage Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Windows Real COM Drivers
Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded
Freefall
IEC-68-2-34, IEC-68-2-32
EMS
EN 61000-4-2 ESD: contact 4 kV; air 8 kV; EN 61000-4-3 RS: 3 V/m (80 MHz to 1 GHz); EN 61000-4-4 EFT: Power 4 kV; Signal 2 kV; EN 61000-4-5 Surge: AC 1 kV (AC models); DC 2 kV (HV models); Signal 1 kV; EN 61000-4-6 CS: 3 V; EN 61000-4-8; EN 61000-4-11: AC m
Safety
UL 60950-1, EN 60950-1
Terminal Sessions
8 sessions per port
Baudrate
50 bps to 921.6 kbps
EMI
EN 55022 Class A, FCC part 15 Subpart B Class A
Storage temperature
Standard Models: -40 to 75°C (-40 to 167°F); Wide Temp. Models: -40 to 75°C (-40 to 167°F); High Voltage Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Automatic Reboot Trigger
Built-in WDT (watchdog timer)
MTBF (mean time between failures)
CN2650I AC models: 99,320 hrs; CN2650I-8-HV-T: 191,326 hrs; CN2650I-16-HV-T: 116,924 hrs
Power Line Protection
1 kV burst (EN 61000-4-4: EFT/B), 2 kV surge (EN 61000-4-5)
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
Input Voltage
AC Models: 100 to 240 VAC, 47 to 63 Hz; DC Models: 110 VDC (88 to 300 VDC)
Configuration Options
Web Console, Serial Console, Telnet Console, Windows Search Utility
Fixed TTY Drivers
SCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X
Standard
Real COM, TCP Server, TCP Client, UDP, RFC2217, Terminal, Reverse Telnet, PPP, DRDAS, Redundant COM, Disabled
Network Protocols
ICMP, IPv4, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP, HTTP, SMTP, ARP, PPPoE, DDNS
RS-422
Tx+, Tx-, Rx+, Rx-, GND
Pull High/Low Resistor for RS-485
1 kΩ, 150 kΩ
Linux Real TTY Drivers
Linux 2.4.x, 2.6.x, 3.x
Connector
CN2610/2650: 8-pin RJ45; CN2650I: DB9 male, 8-pin RJ45
Speed
10/100 Mbps, auto MDI/MDIX
Serial Standards
CN2610: RS-232; CN2650/2650I: RS-232/422/485
Ambient Relative Humidity
5 to 95% (non-condensing)
Number of Ports
8 or 16, 2 (2 IPs)
Flow Control
RTS/CTS, DTR/DSR, XON/XOFF
Terminator for RS-485
120 Ω
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND
Console Port
Dedicated RS-232 console port on rear panel (8-pin RJ45)
Parity
None, Even, Odd, Space, Mark
RS-485-2w
Data+, Data-, GND
Security Protocols
RADIUS, HTTPS, SSH, PAP, CHAP
Magnetic Isolation
1.5 kV built-in
Serial Line Protection
2 kV optical isolation (CN2650I)
RS-485 Data Direction Control
ADDC® (Automatic Data Direction Control)
Power Consumption
CN2650 AC models: 235 mA @ 100 VAC, 145 mA @ 240 VAC; CN2650I HV models: 152 mA @ 88 VDC, 86 mA @ 300 VDC
IP Routing
Static, RIP-I, RIP-II
Alert Tools
Built-in buzzer and RTC (real-time clock)