- Item
- Body for stepping switch - 1 pole - 45 -
- Standards
- IEC 60947-3 power circuit, IEC 60947-5-1 control circuit, CENELEC EN 50013
- Electrical Connection
- captive screw clamp terminals flexible 2 x 1.5 mm², captive screw clamp terminals solid 1 x 2.5 mm²
- Mechanical Durability
- 1000000 cycles
- Protective Treatment
- TC
- [Ui] Rated Insulation Voltage
- 690 V 3)IEC 60947-1
- [Ith] Conventional Free Air Thermal Current
- 12A
- Switching Angle
- 45°
- [Ie] Rated Operational Current AC
1.8 A 690 V AC-3 3 phase IEC 947-3, 2.8 A 500 V AC-3 3 phase IEC 947-3, 2.8 A 690 V AC-23A 3 phase IEC 947-3, 3.3 A 400 V AC-3 3 phase IEC 947-3, 3.8 A 500 V AC-23A 3 phase IEC 947-3, 4.6 A 230 V AC-3 3 phase IEC 947-3, 4.8 A 400 V AC-23A 3 phase IEC 947-3, 5.6 A 230 V AC-23A 3 phase IEC 947-3, 1 A 500 V AC-15 IEC 947-5-1, 2 A 400 V AC-15 IEC 947-5-1, 3 A 230 V AC-15 IEC 947-5-1
- Rated Operational Power In W
10500 W AC-21, 500 - 660 V 3 phase IEC 947-3, 1100 W AC-3, 230 V 3 phase IEC 947-3, 1500 W AC-23A, 230 V 3 phase IEC 947-3, 1500 W AC-3, 400 V 1 phase IEC 947-3, 1500 W AC-3, 400 V 3 phase IEC 947-3, 1500 W AC-3, 500 V 3 phase IEC 947-3, 1500 W AC-3, 690 V 3 phase IEC 947-3, 2200 W AC-23A, 400 V 3 phase IEC 947-3, 2200 W AC-23A, 500 V 3 phase IEC 947-3, 2200 W AC-23A, 690 V 3 phase IEC 947-3, 4800 W AC-21, 230 V 3 phase IEC 947-3, 600 W AC-3, 230 V 1 phase IEC 947-3, 8300 W AC-21, 400 V 3 phase IEC 947-3
- Poles Description
- 1P
- Fixing Mode
- Ø 22 mm hole
- Range of Product
- Harmony K
- Sub-Assembly Composition
- contact blocks + fixing plate
- Bezel Material
- plastic
- Ambient Air Temperature For Operation
- -25-55°C
- Number of Steps
- 4
- Electrical Durability
- 1000000 cycles AC-15, 1000000 cycles AC-21, 500000 cycles AC-23, 500000 cycles AC-3
- Short-Circuit Current
- 10000 A
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV in isolating function, 6 kV IEC 947-1
- Product or Component Type
- cam switch body
- Positive Opening
- with
- Component Name
- K1
- Off Position
- without Off position
- Switching Positions
- right: 0° - 45° - 90° - 135°
- Mounting Location
- front
- Short-Circuit Protection
- 16 A cartridge fuse gG
- [Ithe] Conventional Enclosed Thermal Current
- 10A
- Ambient Air Temperature For Storage
- -40-70°C
- Cam Switch Function
- stepping switch
- Maximum Operating Rate
- 2.5 cyc/mn AC-21, 2.5 cyc/mn AC-23, 2.5 cyc/mn AC-3, 8.333 cyc/mn AC-15
- Shock Resistance
- 30 gn IEC 68-2-27
- Vibration Resistance
- 5 gn 10-150 Hz)IEC 68-2-6
- Contact Operation
- slow-break
- Product Certifications
- CSA 240 V 1 hp 1 phase || CSA 240 V 3 hp 3 phase 2 || UL 240 V 1 hp 3 phase || UL 240 V 0.33 hp 1 phase 2
- [Ie] Rated Operational Current Ac
1.8 A 690 V AC-3 3 phase IEC 947-3 || 2 A 400 V AC-15 IEC 947-5-1 || 3 A 230 V AC-15 IEC 947-5-1 || 2.8 A 500 V AC-3 3 phase IEC 947-3 || 2.8 A 690 V AC-23A 3 phase IEC 947-3 || 3.3 A 400 V AC-3 3 phase IEC 947-3 || 3.8 A 500 V AC-23A 3 phase IEC 947-3 || 4.6 A 230 V AC-3 3 phase IEC 947-3 || 4.8 A 400 V AC-23A 3 phase IEC 947-3 || 5.6 A 230 V AC-23A 3 phase IEC 947-3 || 1 A 500 V AC-15 IEC 947-5-1
- Product Or Component Type
- cam switch body
- Number Of Steps
- 4