IEC Magnetic Contactor, 1NC/1NO, 120V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D80G7

  • Zoro # G0893541


product price:  $456.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
120V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC1D80G7
Zoro #
G0893541
UPC #
785901440864
Country of Origin
Czechia

Dimensions

Working Height
Up to 9842.52 ft
Overall Width
3.35 in
Overall Depth
5.12 in
Overall Height
5 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
120V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
HP @ 1 Phase - 230V
15
HP @ 3 Phase - 575V
60 hp
Enclosure NEMA Rating
No Enclosure
Frame / Series / Class / Code
TeSys
Reversing
No
Series
TeSys Deca
Operating Speed
3600 cycles per hr
Shock Resistance
10 G for 11 ms (Contactor Closed), 8 G for 11 ms (Contactor Open)
Mechanical Durability
4 Mcycles
Impulse Withstand Voltage
8 kV
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1100 A @ 440V (Power Circuit)
Application
Motor Control, Resistive Load
Vibration Resistance
3 G (Contactor Closed), 2 G (Contactor Open)
Inrush VA
245 VA
Switching Voltage
17 V (Signalling Circuit)
Features
Without Built-In Suppressor Module
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
IP Rating
IP20
Fire Rating
UL 94 V1
Tightening Torque
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Watts Loss
6 to 10W
Signalling Circuit Frequency
25 to 400 Hz
Fuse Amps
10 A (Signalling Circuit), 200 A (Type 1 Power Circuit), 160 A (Type 2 Power Circuit)
Control Circuit Voltage Limits
Operational AC: 0.85 to 1.1 Uc (at -40 to 55°C 60 Hz), 0.8 to 1.1 Uc (at -40 to 55°C 50 Hz), 1 to 1.1 Uc (at 55 to 70°C 50/60 Hz); Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz)
Rated Insulation Volts
600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Max. Operating Watts
22 kW (at 220 to 230V AC 50/60 Hz AC-3), 37 kW (at 380 to 400V AC 50/60 Hz AC-3), 45 kW (at 415 to 440V AC 50/60 Hz AC-3), 55 kW (at 500V AC 50/60 Hz AC-3), 45 kW (at 660 to 690V AC 50/60 Hz AC-3), 15 kW (at 400V AC 50/60 Hz AC-4), 22 kW (at 220 to 230V AC 50/60 Hz AC-3e), 37 kW (at 380 to 400V AC 50/60 Hz AC-3e), 45 kW (at 415 to 440V AC 50/60 Hz AC-3e), 55 kW (at 500V AC 50/60 Hz AC-3e), 45 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Includes Protective Cover
Yes
Hold VA
26 VA
Net Weight
1.59 kg
Overvoltage Category
CAT III
Electrical Durability
0.8 Mcycles (125 A, AC-1, Less than 440 V); 1.5 Mcycles (80 A, AC-3, Less than 440 V); 1.5 Mcycles (80 A, AC-3e, Less than 440 V)
Switching Current
5 mA (Signalling Circuit)
Rated Short-Time Withstand Current
640 A (at 40°C for 10 s Power Circuit), 990 A (at 40°C for 1 s Power Circuit), 135 A (at 40°C for 10 min Power Circuit), 320 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Rated Breaking Capacity
1100 A @ 440V
Impedance
0.8 mOhm
Operating Time
20 to 35 ms (Closing), 6 to 20 ms (Opening)
Non-Overlap Time
1.5 ms
Maximum Operating Temperature
140 Degrees F
NEMA Enclosure Rating
No Enclosure
Phase
Three
Full Load Current - Resistive
125 A
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 480V AC
60 hp
Includes Auxiliary Contacts
Yes
Frequency
50/60 Hz
Electrical Operating Durability
1,500,000, 800,000
Resistance Properties
Fire Resistant, Insulation Resistant
Embedded Surge Suppressor
No
Contactor Style
IEC
Mechanical Operating Durability
4,000,000
Minimum Operating Temperature
-40 Degrees F
Horsepower @ Three Phase - 240V AC
30 hp
Full Load Current - Inductive
80 A
Maximum Voltage Rating
300V DC
Number of Normally Open Main Contacts
3
Horsepower @ Three Phase - 600V AC
60 hp
Horsepower @ Single Phase - 120V AC
7 1/2 hp
Horsepower @ Three Phase - 208V AC
30 hp
Horsepower @ Single Phase - 240V AC
15 hp
Conventional Free Air Thermal Current
10 A (at 140°F (60°C)) for signalling circuit; 125 A (at 140°F (60°C)) for power circuit
Protective Cover
With
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Shocks contactor open 8 Gn for 11 ms); Vibrations contactor closed 3 Gn, 5 to 300 Hz); Shocks contactor closed 10 Gn for 11 ms)
Climatic Withstand
IACS E10 exposure to damp heat
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Control Circuit Type
AC 50/60 Hz
Utilisation Category
AC-3; AC-3e; AC-4; AC-1
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Maximum Operating Rate
3600 cyc/h 140°F (60°C)
Rated Operational Current
125 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Control Circuit Voltage
120 V AC 50/60 Hz
Compatibility Code
LC1D
Protective Treatment
THIEC 60068-2-30
Heat Dissipation
6 to 10 W at 50/60 Hz
Inrush Power in VA
245 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 245 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Contactor Application
Motor control; Resistive load
Pollution Degree
3
Power Dissipation Per Pole
5.1 W AC-3; 12.5 W AC-1; 5.1 W AC-3e
Pole Contact Composition
3 NO
Contact Compatibility
M11
Rated Operational Voltage
Power circuit Less than or Equal to 300 V DC 25 to 400 Hz; Power circuit Less than or Equal to 690 V AC
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating

Description

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 80A/1000V AC-3/AC-3e (37kW@400V). They can be used to create motor starters for almost any type of application. It provides a 120V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by screw terminals, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 150A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 175A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Ratings & Reviews

3 Reasons You Can Count On Us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.