Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1
HP @ 3 Phase - 575V
10 hp
Control Circuit Type
DC standard
Auxiliary Contacts Type
mechanically linked 1 NO + 1 NC IEC 60947-5-1, mirror contact 1 NC IEC 60947-4-1
Signalling Circuit Frequency
25...400 Hz
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz) , vibrations contactor closed 4 Gn, 5...300 Hz) , shocks contactor open 10 Gn for 11 ms) , shocks contactor closed 15 Gn for 11 ms)
Rated Breaking Capacity
250 A at 440 V for power circuit conforming to IEC 60947
Climatic Withstand
IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Utilisation Category
AC-1, AC-4, AC-3, AC-3e
Control Circuit Voltage Limits
0.1...0.25 Uc -40-70°C drop-out DC, 0.7...1.25 Uc -40-60°C operational DC, 1...1.25 Uc 60-70°C operational DC
Non-Overlap Time
1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Fire Resistance
850°C IEC 60695-2-1
Contactor Application
motor control, resistive load
Operating Time
63±15 % ms closing, 20±20 % ms opening
Tightening Torque
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, power circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm, control circuit 1.7 N.m screw clamp terminals Philips No 2, control circuit 1.7 N.m screw clamp terminals pozidriv No 2, power circuit 1.7 N.m screw clamp terminals pozidriv No 2
[Ui] Rated Insulation Voltage
power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, signalling circuit 600 V CSA, signalling circuit 600 V UL
Operating Altitude
0...9842.52 ft (0...3000 m)
Protective Treatment
THIEC 60068-2-30
[Icw] Rated Short-Time Withstand Current
105 A 40°C - 10 s for power circuit, 210 A 40°C - 1 s for power circuit, 30 A 40°C - 10 min for power circuit, 61 A 40°C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Power Dissipation Per Pole
0.36 W AC-3, 1.56 W AC-1, 0.36 W AC-3e
Pole Contact Composition
3 NO
Electrical Durability
2 Mcycles 12 A AC-3 <= 440 V, 0.8 Mcycles 25 A AC-1 <= 440 V, 2 Mcycles 12 A AC-3e <= 440 V
Mechanical Durability
30 Mcycles
Maximum Operating Rate
3600 cyc/h 60°C
Max. Operating Watts
3 kW (at 220 to 230V AC 50/60 Hz AC-3), 5.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 5.5 kW 415 to (at 440V AC 50/60 Hz AC-3), 7.5 kW (at 500V AC 50/60 Hz AC-3), 7.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 3.7 kW (at 400V AC 50/60 Hz AC-4), 3 kW (at 220 to 230V AC 50/60 Hz AC-3e), 5.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 5.5 kW 415 to (at 440V AC 50/60 Hz AC-3e), 7.5 kW (at 500V AC 50/60 Hz AC-3e), 7.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Fuse Amps
10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)
Rated Short-Time Withstand Current
105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Rated Insulation Volts
600/690V
Includes Protective Cover
Yes
Features
With Integral Suppression Device
Application
Motor Control, Resistive Load
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Impulse Withstand Voltage
6 kV
Switching Voltage
17 V (Signalling Circuit)
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Operating Speed
3600 cycles per hr
Rated Making Capacity
250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Switching Current
5 mA (Signalling Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Horsepower @ Single Phase - 240V AC
2 hp
Full Load Current - Resistive
25 A
Full Load Current - Inductive
12:00 AM
Horsepower @ Three Phase - 480V AC
7 1/2 hp
Horsepower @ Three Phase - 240V AC
3 hp
Horsepower @ Three Phase - 208V AC
3 hp
Conventional Free Air Thermal Current
25 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit)
Ambient Air Temperature For Operation
-40-60°C, 60-70°C with derating
Mounting Style
Plate, Rail
Hold-In Power Consumption in W
5.4-5.4 W 20°C
Rated Operational Current
25 A (at <60°C) at <= 440 V AC AC-1 for power circuit, 12 A (at <60°C) at <= 440 V AC AC-3 for power circuit, 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Rated Operational Voltage
power circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC
Inrush Power in W
5.4-5.4 W 20°C)
Maximum Voltage Rating
690V AC, 300V DC