- Item
- IEC Magnetic Contactor
- Auxiliary Contact Form
- 1NC/1NO
- Coil Voltage
- 24V DC
- Number of Poles
- 3
- Full Load Amps-Inductive
- 65 A
- Full Load Amps-Resistive
- 80 A
- Reversing Capability
- Non-Reversing
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 2
- Standards
- CCC, CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL Listed
- HP @ 3 Phase - 575V
- 50 hp
- Reversing
- No
- HP @ 1 Phase - 230V
- 10
- Enclosure NEMA Rating
- No Enclosure
- Includes
- Everlink Power Connections
- Series
- TeSys Deca
- Features
- Built-In Bi-Directional Peak Limiting Diode Suppressor
- Control Circuit Voltage Limits
- Drop-Out DC: 0.1 to 0.3 Uc (at -40 to 70°C); Operational DC: 0.75 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C)
- Application
- Motor Control, Resistive Load
- Operating Time
- 42.5 to 57.5 ms (Closing), 16 to 24 ms (Opening)
- Impulse Withstand Voltage
- 6 kV
- Rated Making Capacity
- 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1000 A @ 440V (Power Circuit)
- Net Weight
- 0.935 kg
- Includes Protective Cover
- Yes
- Non-Overlap Time
- 1.5 ms
- Environmental Attributes
- Mercury Free, PVC Free, Pollution Degree 3
- Overvoltage Category
- CAT III
- Signalling Circuit Frequency
- 25 to 400 Hz
- Electrical Durability
- 0.5 Mcycles (80 A, AC-1, Less than 440 V); 1.45 Mcycles (65 A, AC-3, Less than 440 V); 1.45 Mcycles (65 A, AC-3e, Less than 440 V)
- Fuse Amps
- 10 A (Signalling Circuit), 125 A (Type 1 Power Circuit), 125 A (Type 2 Power Circuit)
- Operating Speed
- 3600 cycles per hr
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Rated Short-Time Withstand Current
- 520 A (at 40°C for 10 s Power Circuit), 900 A (at 40°C for 1 s Power Circuit), 110 A (at 40°C for 10 min Power Circuit), 260 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
- Rated Breaking Capacity
- 1000 A @ 440V
- Rated Insulation Volts
- 600/690V
- IP Rating
- IP20
- Tightening Torque
- 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
- Vibration Resistance
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Switching Current
- 5 mA (Signalling Circuit)
- Switching Voltage
- 17 V (Signalling Circuit)
- Fire Rating
- UL 94 V1
- Shock Resistance
- 10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
- Mechanical Durability
- 10 Mcycles
- Impedance
- 1.5 mOhm
- Max. Operating Watts
11 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 30 kW (at 380 to 400V AC 50/60 Hz AC-3), 37 kW (at 500V AC 50/60 Hz AC-3), 37 kW (at 660 to 690V AC 50/60 Hz AC-3), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 30 kW (at 380 to 400V AC 50/60 Hz AC-3e), 37 kW (at 500V AC 50/60 Hz AC-3e), 37 kW (at 660 to 690V AC 50/60 Hz AC-3e)
- Number of Normally Open Main Contacts
- 3
- Horsepower @ Single Phase - 120V AC
- 5 hp
- Resistance Properties
- Fire Resistant, Insulation Resistant
- Full Load Current - Inductive
- 65 A
- Includes Auxiliary Contacts
- Yes
- Mounting Style
- DIN Rail, Plate
- Horsepower @ Three Phase - 600V AC
- 50 hp
- Horsepower @ Three Phase - 480V AC
- 40 hp
- NEMA Enclosure Rating
- No Enclosure
- Horsepower @ Three Phase - 240V AC
- 20 hp
- Horsepower @ Three Phase - 208V AC
- 20 hp
- Electrical Operating Durability
- 1,450,000, 500,000
- Maximum Operating Temperature
- 140 Degrees F
- Frequency
- 50/60 Hz
- Contactor Style
- IEC
- Maximum Voltage Rating
- 690V AC
- Mechanical Operating Durability
- 10,000,000
- Minimum Operating Temperature
- -40 Degrees F
- Full Load Current - Resistive
- 80 A
- Phase
- Three
- Horsepower @ Single Phase - 240V AC
- 10 hp
- Embedded Surge Suppressor
- Yes
- Climatic Withstand
- IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
- Maximum Operating Rate
- 3600 cyc/h 140°F (60°C)
- Protective Treatment
- THIEC 60068-2-30
- Hold-In Power Consumption in W
- 7.4 W 68°F (20°C)
- Pollution Degree
- 3
- Time Constant
- 34 ms
- Conventional Free Air Thermal Current
- 10 A (at 140°F (60°C)) for signalling circuit; 80 A (at 140°F (60°C)) for power circuit
- Operating Altitude
- 0 to 9842.52 ft (0 to 3000 m)
- Power Dissipation Per Pole
- 9.6 W AC-1; 6.3 W AC-3; 6.3 W AC-3e
- Auxiliary Contacts Type
- Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
- Contactor Application
- Motor control; Resistive load
- Protective Cover
- With
- Rated Operational Current
- 80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 65 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 65 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
- Contact Compatibility
- M4
- Mechanical Robustness
- Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 10 Gn for 11 ms)
- Utilisation Category
- AC-4; AC-1; AC-3; AC-3e
- Fire Resistance
- 1562°F (850°C) IEC 60695-2-1
- Pole Contact Composition
- 3 NO
- Control Circuit Type
- DC standard
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Compatibility Code
- LC1D
- Rated Operational Voltage
- Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
- Inrush Power in W
- 19 W 68°F (20°C)
- Ambient Air Temperature For Operation
- -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating