IEC Magnetic Contactor, 1NC/1NO, 120V AC, 3 P, Reversing, Screw Clamp

  • Mfr # LC2D18G7V

  • Zoro # G2464926


product price:  $403.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
120V AC
Number of Poles
3
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC2D18G7V
Zoro #
G2464926
UPC #
785901294719
Country of Origin
France

Dimensions

Working Height
Up to 9842.52 ft
Overall Depth
3.39 in
Overall Width
3.54 in
Overall Height
3.03 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
120V AC
Number of Poles
3
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Enclosure NEMA Rating
No Enclosure
HP @ 3 Phase - 575V
15 hp
Frame / Series / Class / Code
TeSys
Includes
Electrical Interlock, Mechanical Interlock
HP @ 1 Phase - 230V
3
Reversing
Yes
Series
TeSys Deca
Rated Breaking Capacity
300 A @ 440V
IP Rating
IP20
Electrical Durability
1.65 Mcycles (18 A, AC-3, Less than 440 V); 1 Mcycles (32 A, AC-1, Less than 440 V)
Application
Motor Control, Resistive Load
Max. Operating Watts
4 kW (at 220 to 230V AC 50 Hz), 7.5 kW (at 380 to 400V AC 50 Hz), 9 kW (at 415 to 440V AC 50 Hz), 10 kW (at 500V AC 50 Hz), 10 kW (at 660 to 690V AC 50 Hz)
Operating Speed
3600 cycles per hr
Rated Insulation Volts
600/690V
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Non-Overlap Time
1.5 ms
Impedance
2.5 mOhm
Switching Voltage
17 V (Signalling Circuit)
Switching Current
5 mA (Signalling Circuit)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Features
Without Built-In Suppressor Module; Preassembled with Reversing Power Busbar
Fire Rating
UL 94 V1
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit)
Includes Protective Cover
Yes
Rated Short-Time Withstand Current
40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Tightening Torque
1.7 Nm (Control Circuit), 1.7 to 2.5 Nm (Power Circuit)
Operating Time
12 to 22 ms (Closing), 4 to 19 ms (Opening)
Fuse Amps
10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit)
Overvoltage Category
CAT III
Net Weight
0.707 kg
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Inrush VA
70 VA
Impulse Withstand Voltage
6 kV
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Mechanical Durability
15 Mcycles
Signalling Circuit Frequency
25 to 400 Hz
Watts Loss
2 to 3W
Mounting Style
DIN Rail, Plate
Embedded Surge Suppressor
No
Maximum Voltage Rating
690V AC
Frequency
50/60 Hz
Phase
Three
Electrical Operating Durability
1,000,000, 1,650,000
Horsepower @ Three Phase - 480V AC
10 hp
NEMA Enclosure Rating
No Enclosure
Horsepower @ Three Phase - 208V AC
5 hp
Resistance Properties
Fire Resistant, Insulation Resistant
Horsepower @ Single Phase - 240V AC
3 hp
Minimum Operating Temperature
-40 Degrees F
Mechanical Operating Durability
15,000,000
Horsepower @ Three Phase - 240V AC
5 hp
Full Load Current - Inductive
18 A
Horsepower @ Single Phase - 120V AC
1 hp
Horsepower @ Three Phase - 600V AC
15 hp
Number of Normally Open Main Contacts
3
Contactor Style
IEC
Includes Auxiliary Contacts
Yes
Maximum Operating Temperature
140 Degrees F
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Inrush Power in VA
70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Maximum Operating Rate
3600 cyc/h 140°F (60°C)
Protective Treatment
TH IEC 60068-2-30
Rated Operational Current
18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit
Device Presentation
Preassembled with reversing power busbar
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Contactor Application
Motor control; Resistive load
Climatic Withstand
IACS E10; IEC 60947-1 Annex Q category D
Heat Dissipation
2 to 3 W 50/60 Hz
Control Circuit Type
AC 50/60 Hz
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
Pollution Degree
3
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Ambient Air Temperature For Storage
-76 to 176°F (-60 to 80°C)
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Product Name
TeSys D; TeSys Deca
Control Circuit Voltage
120 V AC 50/60 Hz
Front Cover
With
Mechanical Robustness
Vibrations contactor open2 Gn, 5 to 300 Hz; Vibrations contactor closed4 Gn, 5 to 300 Hz; Shocks contactor open10 Gn for 11 ms; Shocks contactor closed15 Gn for 11 ms
Interlocking Type
Electrical and mechanical
Utilisation Category
AC-3; AC-1
Conventional Free Air Thermal Current
10 A (at 140°F (60°C)) for signalling circuit; 32 A (at 140°F (60°C)) for power circuit
Power Dissipation Per Pole
0.8 W AC-3; 2.5 W AC-1
Full Load Current - Resistive
32 A
Pole Contact Composition
3 NO

Description

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 3, Full Load Current - Inductive 18 A, Reversing Capability Reversing, Overall Height 3.03 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 5 hp

Ratings & Reviews

3 Reasons You Can Count On Us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.