- Item
- IEC Magnetic Contactor
- Auxiliary Contact Form
- 1NC/1NO
- Coil Voltage
- 120V AC
- Number of Poles
- 3
- Full Load Amps-Inductive
- 18 A
- Full Load Amps-Resistive
- 32 A
- Reversing Capability
- Reversing
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 2
- Standards
- BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
- Enclosure NEMA Rating
- No Enclosure
- HP @ 3 Phase - 575V
- 15 hp
- Frame / Series / Class / Code
- TeSys
- Includes
- Electrical Interlock, Mechanical Interlock
- HP @ 1 Phase - 230V
- 3
- Reversing
- Yes
- Series
- TeSys Deca
- Rated Breaking Capacity
- 300 A @ 440V
- IP Rating
- IP20
- Electrical Durability
- 1.65 Mcycles (18 A, AC-3, Less than 440 V); 1 Mcycles (32 A, AC-1, Less than 440 V)
- Application
- Motor Control, Resistive Load
- Max. Operating Watts
- 4 kW (at 220 to 230V AC 50 Hz), 7.5 kW (at 380 to 400V AC 50 Hz), 9 kW (at 415 to 440V AC 50 Hz), 10 kW (at 500V AC 50 Hz), 10 kW (at 660 to 690V AC 50 Hz)
- Operating Speed
- 3600 cycles per hr
- Rated Insulation Volts
- 600/690V
- Environmental Attributes
- Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
- Non-Overlap Time
- 1.5 ms
- Impedance
- 2.5 mOhm
- Switching Voltage
- 17 V (Signalling Circuit)
- Switching Current
- 5 mA (Signalling Circuit)
- Vibration Resistance
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Hold VA
- 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
- Features
- Without Built-In Suppressor Module; Preassembled with Reversing Power Busbar
- Fire Rating
- UL 94 V1
- Rated Making Capacity
- 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit)
- Includes Protective Cover
- Yes
- Rated Short-Time Withstand Current
- 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
- Tightening Torque
- 1.7 Nm (Control Circuit), 1.7 to 2.5 Nm (Power Circuit)
- Operating Time
- 12 to 22 ms (Closing), 4 to 19 ms (Opening)
- Fuse Amps
- 10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit)
- Overvoltage Category
- CAT III
- Net Weight
- 0.707 kg
- Control Circuit Voltage Limits
- Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
- Inrush VA
- 70 VA
- Impulse Withstand Voltage
- 6 kV
- Shock Resistance
- 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Mechanical Durability
- 15 Mcycles
- Signalling Circuit Frequency
- 25 to 400 Hz
- Watts Loss
- 2 to 3W
- Mounting Style
- DIN Rail, Plate
- Embedded Surge Suppressor
- No
- Maximum Voltage Rating
- 690V AC
- Frequency
- 50/60 Hz
- Phase
- Three
- Electrical Operating Durability
- 1,000,000, 1,650,000
- Horsepower @ Three Phase - 480V AC
- 10 hp
- NEMA Enclosure Rating
- No Enclosure
- Horsepower @ Three Phase - 208V AC
- 5 hp
- Resistance Properties
- Fire Resistant, Insulation Resistant
- Horsepower @ Single Phase - 240V AC
- 3 hp
- Minimum Operating Temperature
- -40 Degrees F
- Mechanical Operating Durability
- 15,000,000
- Horsepower @ Three Phase - 240V AC
- 5 hp
- Full Load Current - Inductive
- 18 A
- Horsepower @ Single Phase - 120V AC
- 1 hp
- Horsepower @ Three Phase - 600V AC
- 15 hp
- Number of Normally Open Main Contacts
- 3
- Contactor Style
- IEC
- Includes Auxiliary Contacts
- Yes
- Maximum Operating Temperature
- 140 Degrees F
- Rated Operational Voltage
- Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
- Inrush Power in VA
- 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
- Maximum Operating Rate
- 3600 cyc/h 140°F (60°C)
- Protective Treatment
- TH IEC 60068-2-30
- Rated Operational Current
- 18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit
- Device Presentation
- Preassembled with reversing power busbar
- Auxiliary Contacts Type
- Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
- Contactor Application
- Motor control; Resistive load
- Climatic Withstand
- IACS E10; IEC 60947-1 Annex Q category D
- Heat Dissipation
- 2 to 3 W 50/60 Hz
- Control Circuit Type
- AC 50/60 Hz
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Ambient Air Temperature For Operation
- -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
- Pollution Degree
- 3
- Fire Resistance
- 1562°F (850°C) IEC 60695-2-1
- Ambient Air Temperature For Storage
- -76 to 176°F (-60 to 80°C)
- Operating Altitude
- 0 to 9842.52 ft (0 to 3000 m)
- Product Name
- TeSys D; TeSys Deca
- Control Circuit Voltage
- 120 V AC 50/60 Hz
- Front Cover
- With
- Mechanical Robustness
- Vibrations contactor open2 Gn, 5 to 300 Hz; Vibrations contactor closed4 Gn, 5 to 300 Hz; Shocks contactor open10 Gn for 11 ms; Shocks contactor closed15 Gn for 11 ms
- Interlocking Type
- Electrical and mechanical
- Utilisation Category
- AC-3; AC-1
- Conventional Free Air Thermal Current
- 10 A (at 140°F (60°C)) for signalling circuit; 32 A (at 140°F (60°C)) for power circuit
- Power Dissipation Per Pole
- 0.8 W AC-3; 2.5 W AC-1
- Full Load Current - Resistive
- 32 A
- Pole Contact Composition
- 3 NO