IEC Miniature Magnetic Contactor, 1NC, 24V AC, 3 P, Reversing, Screw Clamp

  • Mfr # LC2K0901B7

  • Zoro # G1375622


product price:  $182.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC
Coil Voltage
24V AC
Number of Poles
3
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Real support from real people
Contact our U.S. based team

Specifications

Product Information

MFR #
LC2K0901B7
Zoro #
G1375622
UPC #
785901882800
Country of Origin
France

Dimensions

Working Height
6561.68 ft
Overall Width
3.54 in
Overall Height
2.28 in
Overall Depth
2.24 in

Details

Item
IEC Miniature Magnetic Contactor
Auxiliary Contact Form
1NC
Coil Voltage
24V AC
Number of Poles
3
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
HP @ 1 Phase - 230V
1-1/2
Reversing
Yes
HP @ 3 Phase - 575V
5 hp
Frame / Series / Class / Code
TeSys
Enclosure NEMA Rating
No Enclosure
Series
TeSys K
Impulse Withstand Voltage
8 kV
Rated Insulation Volts
600/690V
Overvoltage Category
CAT III
Impedance
3 mOhm
Watts Loss
1.3W
IP Rating
IP20
Fuse Amps
25 A (Power Circuit), 10 A (Signalling Circuit)
Max. Operating Watts
2.2 kW (at 220 to 230V AC 50/60 Hz), 4 kW (at 380 to 415VAC 50/60 Hz), 4 kW (at 440V AC 50/60 Hz), 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz)
Operating Speed
3600 cycles per hr
Hold VA
4.5 VA
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Control Circuit Voltage Limits
Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Rated Making Capacity
110 A
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free
Rated Short-Time Withstand Current
90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 20 A (at 50°C for 15 min Power Circuit)
Operating Time
10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
Tightening Torque
0.8 to 1.3 Nm
Shock Resistance
10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Net Weight
0.39 kg
Fire Rating
UL 94 V1, NF F 16-101, NF F 16-102
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Rated Breaking Capacity
110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
Signalling Circuit Frequency
Less Than 400 Hz
Switching Voltage
17 V (Signalling Circuit)
Mechanical Durability
5 Mcycles
Electrical Durability
0.18 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (9 A, AC-3, Less than 440 V); 1.3 Mcycles (9 A, AC-3e, Less than 440 V)
Switching Current
5 mA (Signalling Circuit)
Inrush VA
30 VA
Features
Preassembled with Reversing Power Busbar
Application
Motor Control, Resistive Load
Full Load Current - Inductive
9:00 AM
Number of Normally Open Main Contacts
3
Resistance Properties
Insulation Resistant
Frequency
50/60 Hz
Contactor Style
IEC
Horsepower @ Single Phase - 240V AC
1 1/2 hp
Full Load Current - Resistive
20 A
Horsepower @ Three Phase - 600V AC
5 hp
Mounting Style
DIN Rail, Plate
Maximum Voltage Rating
690V AC
Minimum Operating Temperature
-13 Degrees F
Electrical Operating Durability
1,300,000, 180,000
Horsepower @ Three Phase - 480V AC
5 hp
Includes Auxiliary Contacts
Yes
Mechanical Operating Durability
5,000,000
Horsepower @ Three Phase - 240V AC
3 hp
Horsepower @ Three Phase - 208V AC
2 hp
NEMA Enclosure Rating
No Enclosure
Horsepower @ Single Phase - 120V AC
1/2 hp
Maximum Operating Temperature
122 Degrees F
Embedded Surge Suppressor
No
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Control Circuit Voltage
24 V AC 50/60 Hz
Mechanical Robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Interlocking Type
Mechanical
Control Circuit Type
AC 50/60 Hz
Ambient Air Temperature For Operation
-13 to 122°F (-25 to 50°C)
Rated Operational Voltage
Power circuit 690 V AC 50/60 Hz; Signalling circuit Less than or Equal to 690 V AC 50/60 Hz
Utilisation Category
AC-3; AC-3e; AC-4; AC-1
Device Application
Control
Heat Dissipation
1.3 W
Non Overlap Distance
0.02 in (0.5 mm)
Ambient Air Temperature For Storage
-58 to 176°F (-50 to 80°C)
Maximum Operating Rate
3600 cyc/h
Operating Altitude
6561.68 ft (2000 m) without derating
Inrush Power in VA
30 VA (at 68°F (20°C))
Conventional Free Air Thermal Current
20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Auxiliary Contacts Type
Instantaneous 1 NC
Rated Operational Current
9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Protective Treatment
TC IEC 60068; TC DIN 50016
Contactor Application
Motor control; Resistive load
Pole Contact Composition
3 NO

Description

The SCHNEIDER ELECTRIC - IEC Miniature Magnetic Contactor is a contactor with the ability to reverse its action for various industrial applications. It's designed for motor control and resistive load applications, operating with a coil voltage of 24V AC and featuring an auxiliary contact configuration of 1NC (Normally Closed). The device is rated for operation within specified ambient air temperature ranges: from -13 to 122°F (-25 to 50°C) during operation, and -58 to 176°F (-50 to 80°C) when stored. Its screw clamp terminals are compatible with certain cable types, offering flexibility in terms of cable compatibility. This product belongs to the TeSys series and complies with several recognized international standards including BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660.

Key Features:

  • Action may be reversed for various industrial applications
  • Rated for operation within specified ambient air temperature ranges
  • Auxiliary Contacts Type: Instantaneous NC (Normally Closed)
  • Screw clamp terminals compatible with certain cable types
  • Complies with several recognized international standards
  • Rated insulation voltage: Power circuit at both 600 V UL508 &690 V IEC60947-4-1; Signalling circuit at both690 V IEC60947-5-1 &600 V UL508.
  • Device application: Control
  • Maximum operating rate:3600 cyc/h
  • Mounting style:DIN Rail or Plate.
  • Ratings & Reviews

    3 Reasons You Can Count On Us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.