- Item
- Motor Controller
- Auxiliary Contact Form
- 1NC/4NO
- Minimum Overload Relay Current Setting
- 1.35 A
- Maximum Overload Relay Current Setting
- 27 A
- Overload Protection Type
- Thermal
- Maximum Voltage Rating
- 690V AC
- Standards
- CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, LROS, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nKERI, nNOM, nRINA, nRMRoS, nUL, UL 508
- Interface
- DeviceNet
- For Use With
- Short Circuit Protection And A Contactor
- Control Voltage
- 100-240V AC
- Current Consumption
- 8 to 62.8 mA
- Maximum Operating Rate
- 1800 cyc/h
- Protection Type
- thermal overload protection || power factor variation || phase failure || overload (long time) || reverse polarity protection || earth-leakage protection || thermal protection || locked rotor || load fluctuation || overload || phase unbalance
- Current State 1 Guaranteed
- logic input 79 to 264 V >= 2 mA 25 ms
- Electromagnetic Compatibility
electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
- Permissible Power
- 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
- Tightening Torque
- control circuit 0.5-0.6 N.m flat 3 mm
- Device Short Name
- LTMR
- Compatibility Code
- LTMR
- Bus Type
- DeviceNet ISO 1198 1 to 64 125 to 500 kbit/s, terminal block 4 twisted shielded pairs cable
- Connection Pitch
- 5.08 mm
- Product Name
- TeSys T
- Communication Port Protocol
- DeviceNet
- Operating Altitude
- <= 6561.68 ft (2000 m) without derating
- Short-Circuit Withstand
- 100 kA conforming to EN/IEC 60947-4-1
- Web Services
- web server
- Mechanical Robustness
- vibrations mounted on symmetrical rail1 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
- Input Current
- 3.1 mA 100 V || 7.5 mA 240 V
- Measurement Accuracy
- 5 to 15 % earth fault current internal measurement || 1 % voltage 100 to 830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
- Ambient Air Temperature For Storage
- -40-80°C
- Product Or Component Type
- motor controller
- Current State 0 Guaranteed
- logic input 0 to 40 V <= 15 mA 25 ms
- Ambient Air Temperature For Operation
- -20-60°C
- Network And Machine Diagnosis Type
trip history information || trip context information || running hours counter/operating time || remaining operating time before overload tripping || fault recording || waiting time after overload tripping || starting current and time || phase fault and earth fault trip counters || event recording || motor control command recording
- Load Current
- 5 A 250 V AC logic output || 5 A 30 V DC logic output
- Protective Treatment
- 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
- Fire Resistance
- 650°C EN/IEC 60695-2-12 || 960°C UL 94
- Maximum Operating Frequency
- 2 Hz
- Associated Fuse Rating
- 4 A gG output || 0.5 A gG control circuit
- Overvoltage Category
- III
- Product Certifications
- LROS (Lloyds register of shipping) || NOM || GL || C-tick || ATEX || KERI || DNV || BV || RINA || UL || RMRoS || EAC || CCC || CSA || ABS
- Pollution Degree
- 3
- Connections - Terminals
control circuit connector 1 0.25-2.5 mm² AWG 24 to AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24 to AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24 to AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24 to AWG 14)solid without cable end
- Measurement Current
- 1.35-27 A
- Metering Type
- imbalance current || temperature || earth-fault current || average current Iavg || phase current I1, I2, I3 RMS
- Logic Input Number
- 6
- Supply Voltage Limits
- 93.5-264 V AC
- Range
- TeSys
- Number of Contacts Included
- 5
- Number of Normally Open Contacts
- 4
- Compatible with Series
- TeSys T
- Number of Normally Closed Contacts
- 1
- Maximum Current Rating
- 27 A
- Minimum Current Rating
- 1.35 A
- Rated Insulation Voltage
- 690 V EN/IEC 60947-1; 690 V CSA C22.2 No 14; 690 V UL 508
- Rated Impulse Withstand Voltage
- 4 kV supply, inputs and outputs EN/IEC 60947-4-1; 6 kV current or voltage measurement circuit EN/IEC 60947-4-1; 0.8 kV communication circuit EN/IEC 60947-4-1
- Contact Type and Composition
- 1 NO + 1 NC fault signal; 3 NO
- IP Rating
- IP20
- Relay Application
- equipment monitoring and control
- Trip Clss
- 5/30