BV, CSA, CSA C22.2 No.14, DNV, EN/IEC 60947-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, GL, JIS C8201-1, JIS C8201-5-1, LROS, UL 508, UL Listed
Switch Operation @ Position D
No Fourth Position
Series
XB5
DC Contact Rating
0.1 A @ 600 V, 0.27 A @ 250 V, 0.55 A @ 125 V
AC Contact Rating
1.2 A @ 600 V, 3 A @ 240 V, 6 A @ 120 V
Resistance To High Pressure Washer
7000000 Pa 55°C 0.1 m
Device Presentation
complete product
Tightening Torque
0.8-1.2 N.m EN 60947-1
Contact Operation
slow-break
Ik Degree Of Protection
IK06 IEC 50102
Electrical Durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
Product Certifications
UL || GL || LROS (Lloyds register of shipping) || DNV || CSA || BV
Contacts Usage
standard contacts
[Ie] Rated Operational Current
3 A 240 V, AC-15, A600 EN/IEC 60947-5-1 || 6 A 120 V, AC-15, A600 EN/IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1
Torque Value
0.14 N.m NO changing electrical state
Ambient Air Temperature For Operation
-40-70°C
Electrical Reliability
λ < 10exp(-6) 5 V, 1 mA in clean environment EN/IEC 60947-5-4 || λ < 10exp(-8) 17 V, 5 mA in clean environment EN/IEC 60947-5-4
Short-Circuit Protection
10 A cartridge fuse gG EN/IEC 60947-5-1
Electrical Shock Protection Class
class II IEC 60536
Contacts Type And Composition
2 NO
[Ui] Rated Insulation Voltage
600 V 3)EN 60947-1
Operator Position Information
3 positions +/- 45°
Positive Opening
without
Terminals Description Iso N°1
(13-14)NO
Ip Degree Of Protection
IP67 IEC 60529 || IP69 || IP69K
Shape Of Signaling Unit Head
round
[Ith] Conventional Free Air Thermal Current
10 A EN/IEC 60947-5-1
Shock Resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Mechanical Durability
1000000 cycles
Vibration Resistance
5 gn 2-500 Hz)IEC 60068-2-6
Product Or Component Type
selector switch
Head Type
standard
Nema Degree Of Protection
NEMA 13 || NEMA 4X
Operator Profile
black standard handle
Protective Treatment
TH
Contacts Material
silver alloy (Ag/Ni)
Device Short Name
XB5
Connections - Terminals
screw clamp terminals, <= 2 x 1.5 mm² with cable end EN/IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end EN/IEC 60947-1
Shape Of Screw Head
cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm
[Uimp] Rated Impulse Withstand Voltage
6 kV EN 60947-1
Ambient Air Temperature For Storage
-40-70°C
Rated Operational Current
3 A 240 V, AC-15, A600 IEC 60947-5-1; 6 A 120 V, AC-15, A600 IEC 60947-5-1; 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1; 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1; 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1; 1.2 A 600 V, AC-15, A600 IEC 60947-5-1
Conventional Free Air Thermal Current
10 A IEC 60947-5-1
Rated Insulation Voltage
600 V 3)IEC 60947-1
Rated Impulse Withstand Voltage
6 kV IEC 60947-1
Terminals Description Iso N°1
(13-14)NO
Operator Head Type
Short-Handled Knob
Contact Block Material
Plastic
Operator Illumination
Non-Illuminated
Switch Function @ 3rd Position
On
Switch Function @ 2nd Position
Off
NEMA Enclosure Rating
1, 12, 13, 2, 3, 3R, 4, 4X
Switch Function @ 1st Position
On
Number of Positions
3
Operator Head Color
Black
Hazardous Location Specification
Not Rated
Switch Function @ 4th Position
No Fourth Position
Description
Selector Switch, 22 mm, 3 Position, Maintained/Maintained/Maintained Action, 2NO Contact Form, Type of Operator Lever, Color Black, No Key Key Removal, Operator Head Material Plastic, Basic Material Plastic, Bezel Material Plastic, Bezel Color Chrome, Contact Rating 10A @ 600V AC, NEMA Contact Rating Designation B600/Q600, NEMA Rating 1, 12, 13, 2, 3, 4, 4X, IP Rating IP67, IP69, IP69K, Cam No Cam Included, Switch Operation @ Position A XO, Switch Operation @ Position B OO