Zoro Homepage

Overload Module, 3 A Min current, 12 A Max current, 690V AC

  • Mfr # LUCB12BL

  • Zoro # G0561797


product price: $171.99
/ea
Free Shipping & Returns

Key Features

Minimum Overload Relay Current Setting
3:00 AM
Maximum Overload Relay Current Setting
12:00 AM
Trip Class
10
Overload Protection Type
Thermal
Maximum Voltage Rating
690V AC
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Real support from real people
Contact our U.S. based team

Specifications

Product Information

MFR #
LUCB12BL
Zoro #
G0561797
UPC #
785901221791
Country of Origin
France

Dimensions

Depth
60 mm
Width
45 mm
Height
66 mm
Body Height - Relay
2.6 in
Overall Height - Relay
2.6 in
Body Depth - Relay
2.36 in

Details

Item
Overload Module
Minimum Overload Relay Current Setting
3:00 AM
Maximum Overload Relay Current Setting
12:00 AM
Trip Class
10
Overload Protection Type
Thermal
Maximum Voltage Rating
690V AC
Standards
CSA C22.2 No 60947-4-1, EN 60947-6-2, IEC 60947-6-2, REACH, RoHS, UL Listed 60947-4-1
Coil Volts
24V DC
Number of Poles
3
Hz
40 to 60 Hz
Features
Manual reset; Protection against phase failure and phase imbalance; Protection against overload and short-circuit; Earth fault protection; Free of Halogen, Mercury & Pvc Free; Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration
Frame / Series / Class / Code
Class 10
Kit Required for Retrofit Mtg.
No
Sensing Method
Thermal
Trip Class - Overload
10
Use With - Contactors and Starters
Mfr. Series LUA1C Contactors
Separate Mounting
No
Phase
Three
Reset Type
Manual
Maximum Operating Temperature
158 Degrees F
Compatible with Series
TeSys Ultra
Maximum Rated Motor Current Adjustment
12 A
Minumum Rated Motor Current Adjustment
3 A
Minimum Operating Temperature
-13 Degrees F
Compatible Manufacturer Model Number
LUB120, LUB320, LUB380
Rated Impulse Withstand Voltage
6 kV IEC 60947-6-2
Product Specific Application
Basic protection and advanced functions, communication
Compatibility Code
LUCB
Safe Separation Of Circuit
400 V SELV between the control and auxiliary circuits IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Fixing Mode
Plug-in front face)
Resistance To Radiated Fields
9.14 V/m (10 V/m) 3 IEC 61000-4-3
Ambient Air Temperature For Storage
-40 to 185°F (-40 to 85°C)
Immunity To Voltage Dips
70% / 500 ms IEC 61000-4-11
Immunity To Microbreaks
3 ms
Resistance To Electrostatic Discharge
8 kV 3 in open air IEC 61000-4-2; 8 kV 4 on contact IEC 61000-4-2
Phase Failure Sensitivity
Yes
Thermal Overload Class
Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) IEC 60947-6-2; Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) UL 508
Motor Power KW
5.5 kW 400 to 440 V AC 50/60 Hz; 5.5 kW 500 V AC 50/60 Hz; 9 kW 690 V AC 50/60 Hz
Protective Treatment
TH IEC 60068
Utilisation Category
AC-41; AC-43; AC-44
Product Compatibility
Power base LUB12; Power base LUB32; Power base LUB38; Power base LUB120; Power base LUB320; Power base LUB380; Reversing contactor breaker LU2B12BL; Reversing contactor breaker LU2B32BL; Reversing contactor breaker LU2B38BL
Tripping Threshold
14.2 x Ir +/- 20%
Rated Insulation Voltage
690 V IEC 60947-6-2; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1
Control Circuit Voltage Limits
20 to 27 V DC 24 V in operation; 14.5 V DC 24 V drop-out
Immunity To Radioelectric Fields
10 V IEC 61000-4-6
Vibration Resistance
2 gn 5 to 300 Hz power poles open IEC 60068-2-6; 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6
Operating Time
35 ms opening with LUB12 control circuit; 35 ms opening with LUB32 control circuit; 35 ms opening with LUB38 control circuit; 70 ms closing with LUB12 control circuit; 70 ms closing with LUB32 control circuit; 70 ms closing with LUB38 control circuit
Rated Operational Voltage
690 V AC
Load Type
3-phase motor self-cooled
Operating Altitude
6561.68 ft (2000 m)
Fire Resistance
1760°F (960°C) parts supporting live components IEC 60695-2-12; 1202°F (650°C) IEC 60695-2-12
Main Function Available
Manual reset; Protection against phase failure and phase imbalance; Protection against overload and short-circuit; Earth fault protection
Heat Dissipation
2 W control circuit with LUB12; 3 W control circuit with LUB32; 3 W control circuit with LUB38
Ambient Air Temperature For Operation
-13 to 158°F (-25 to 70°C)
Typical Current Consumption
130 mA 24 V DC I maximum while closing with LUB12; 220 mA 24 V DC I maximum while closing with LUB32; 220 mA 24 V DC I maximum while closing with LUB38; 60 mA 24 V DC I rms sealed with LUB12; 80 mA 24 V DC I rms sealed with LUB32; 80 mA 24 V DC I rms sealed with LUB38
Product Or Component Type
Advanced control unit
Shock Resistance
10 gn power poles open IEC 60068-2-27; 15 gn power poles closed IEC 60068-2-27
Product Certifications
CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine
Resistance To Fast Transients
2 kV 3 serial link IEC 61000-4-4; 4 kV 4 all circuits except for serial link IEC 61000-4-4
IP Rating
IP20
Relay Application
Motor control; Motor protection

Description

Overload Module, Maximum Rated Motor Current Adjustment 12 A, Minumum Rated Motor Current Adjustment 3 A, Coil Voltage 24V DC, Compatible with Series TeSys Ultra, Trip Class 10, Phase Three, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards CSA C22.2 No 60947-4-1, EN 60947-6-2, IEC 60947-6-2, REACH, RoHS, UL Listed 60947-4-1, Compatible Grainger Part Number 48P499, 48P503, Maximum Operating Temperature 158 Degrees F, Minimum Operating Temperature -13 Degrees F

Ratings & Reviews

3 Reasons You Can Count On Us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.