- MFR #
- LRD05L
- Zoro #
- G5383244
- UPC #
- 785901149583
- Country of Origin
- Thailand
- Item
- Overload Relay
- Auxiliary Contact Form
- 1NC/1NO
- Minimum Overload Relay Current Setting
- 0.63 A
- Maximum Overload Relay Current Setting
- 1:00 AM
- Trip Class
- 20
- Overload Protection Type
- Thermal
- Maximum Voltage Rating
- 690V AC
- Standards
- CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN/IEC 60947-4-1, EN/IEC 60947-5-1, REACH, RoHS, UL 60947-4-1, UL 60947-5-1
- Use With - Contactors and Starters
- Mfr. Series LC1D09 to LC1D32 Contactors
- Sensing Method
- Bimetallic
- Number of Poles
- 3
- Separate Mounting
- No
- Trip Class - Overload
- 20
- Features
- Single Phase Sensitivity; Differential
- For Use With
- TeSys D 9-32A, TeSys N Size 00-1 Contactors
- Starter Type
- IEC
- Product Name
- TeSys LRD || TeSys Deca
- Network Frequency
- 0 to 400 Hz
- Thermal Protection Adjustment Range
- 0.63-1 A
- Tripping Threshold
- 1.14 +/- 0.06 Ir IEC 60947-4-1
- Product Compatibility
- LC1D12 || LC1D25 || LC1D18 || LC1D38 || LC1D09 || LC1D32
- Product Or Component Type
- differential thermal overload relay
- Network Type
- DC || AC
- Product Certifications
- IEC || UL || CSA || EAC || ABS || ATEX INERIS || UKCA
- Relay Application
- motor protection
- Thermal Overload Class
- class 20 IEC 60947-4-1
- Phase Failure Sensitivity
- tripping current 130 % of Ir on two phase, the last one at 0
- Ambient Air Temperature For Storage
- -60-70°C
- Associated Fuse Rating
- 4 A gG signalling circuit || 4 A BS signalling circuit
- Mechanical Robustness
- shocks15 Gn for 11 ms IEC 60068-2-7 || vibrations3 GN IEC 60068-2-6
- Connections - Terminals
control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit screw clamp terminals 1 1.5-10 mm² flexible without cable end || power circuit screw clamp terminals 1 1-4 mm² flexible with cable end || power circuit screw clamp terminals 1 1-6 mm² solid without cable end
- Tightening Torque
- control circuit 1.7 N.m screw clamp terminals || power circuit 1.7 N.m screw clamp terminals
- Control Type
- Red push-button stop || Blue push-button reset
- Climatic Withstand
- IACS E10
- Permissible Current
- 3 A 120 V AC-15 signalling circuit || 0.22 A 125 V DC-13 signalling circuit
- Ambient Air Temperature For Operation
- -20-60°C without derating IEC 60947-4-1
- Dielectric Strength
- 1.89 kV 50 Hz IEC 60947-1
- Device Short Name
- LRD
- Range
- TeSys || TeSys Deca
- Terminal Connection Type
- Screw Clamp Terminals
- Maximum Operating Temperature
- 140 Degrees F
- IP Rating
- IP20
- Compatible with Series
- TeSys Deca
- Mounting Style
- Direct To Contactor
- Reset Type
- Auto, Manual
- Relay Style
- IEC
- Minimum Operating Temperature
- -4 Degrees F
- Rated Insulation Voltage
- power circuit 600 V CSA || power circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- Rated Operational Voltage
- 690 V AC 0 to 400 Hz power circuit IEC 60947-4-1
- Conventional Free Air Thermal Current
- 5 A signalling circuit
- Trip Clss
- 20