EN 50470-3 || EN 50470-1 || IEC 62053-22 || IEC 60529 || UL 61010-1 || IEC 62053-24 || IEC 61557-12 || ANSI C12.20; CE IEC 61010-1 || cULus UL 61010-1 || BTL; class 0.2S active energy IEC 62053-22
Mounting Style
Clip-on
Weight
450 g
Web Services
diagnostic via predefined web pages || real time viewing of data || web server || alarm notification by e-mail
Power Quality Analysis
up to the 63rd harmonic
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pollution Degree
2
Connections - Terminals
voltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || RS485 link screw terminal block4 || digital input screw terminal block8 || digital output screw terminal block4 || Ethernet network RJ45 connector2
Type Of Measurement
current || voltage || frequency || power factor || energy || active and reactive power
Analogue Input Type
voltage 5 MOhm) || current <= 0.3 mOhm)
Ethernet Service
SNTP client || SNMP-Traps
Communication Port Protocol
Modbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires 2500 V || JBUS || Modbus TCP/IP 10/100 Mbit/s 2500 V || Ethernet Modbus TCP/IP daisy chain || BACnet IP || DNP3 over ethernet
Ride-Through Time
35 ms 120 V AC typical || 129 ms 230 V AC typical || 50 ms 125 V DC typical
Frequency Measurement Range
45-65 Hz
Communication Port Support
RS485 || ETHERNET
Ip Degree Of Protection
display IP54 IEC 60529 || rear IP30 IEC 60529
Circularity Profile
ENVEOLI1412028EN
Measurement Current
50-10000 mA
Measurement Accuracy
apparent power +/- 0.5 % || frequency +/- 0.05 % || active energy +/- 0.2 % || reactive energy +/- 1 % || active power +/- 0.2 % || voltage +/- 0.1 % || power factor +/- 0.005 || current +/- 0.15 % || reactive power +/- 1 %
Device Short Name
PM5563
Number Of Inputs
4 digital
Device Application
gateway || power monitoring || WAGES metering || multi-tariff
Primary/Ambient Air Temp.
-25-70°C; -40-85°C
Range
PowerLogic
Memory Capacity
1.1 MB
Network Frequency
50 Hz || 60 Hz
Maximum Power Consumption In Va
16 VA 480 V
Sampling Rate
128 samples/cycle
Metering Type
measured neutral current || calculated ground current
Information Displayed
tariff 8)
Measurement Voltage
20-400 V AC 45...65 Hz between phase and neutral || 20-828 V AC 45...65 Hz between phases
Communication Gateway
Ethernet/serial
Number Of Outputs
2 digital
Display Resolution
128 x 128 pixels
Electromagnetic Compatibility
limits for harmonic current emissionsclass A IEC 61000-3-2 || conducted RF disturbanceslevel 3 IEC 61000-4-6 || magnetic field at power frequencylevel 4 IEC 61000-4-8 || conducted and radiated emissionsclass B EN 55022 || limitation of voltage changes, voltage fluctuations and flicker in low-voltage IEC 61000-3-3 || electrostatic discharge 8 kVlevel 4 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test IEC 61000-4-3 || electrical fast transient/burst immunity testlevel 4 IEC 61000-4-4 || surge immunity testlevel 4 IEC 61000-4-5 || voltage dips and interruptions immunity test IEC 61000-4-11
Data Recording
time stamping || data logs || maintenance logs || event logs || alarm logs || min/max of instantaneous values