Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
HP @ 3 Phase - 575V
100 hp
Frame / Series / Class / Code
TeSys
Enclosure NEMA Rating
No Enclosure
Shock Resistance
15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Overvoltage Category
CAT III
Electrical Durability
0.8 Mcycles (200 A, AC-1, Less than 440 V); 0.95 Mcycles (115 A, AC-3, Less than 440 V); 0.95 Mcycles (115 A, AC-3e, Less than 440 V)
Rated Insulation Volts
600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Includes Protective Cover
Yes
Switching Voltage
17 V (Signalling Circuit)
Rated Making Capacity
1260 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Features
With Integral Suppression Device
Switching Current
5 mA (Signalling Circuit)
Signalling Circuit Frequency
25 to 400 Hz
Max. Operating Watts
30 kW (at 220 to 230V AC 50/60 Hz AC-3), 55 kW (at 380 to 400V AC 50/60 Hz AC-3), 59 kW 415 to (at 440V AC 50/60 Hz AC-3), 75 kW (at 500V AC 50/60 Hz AC-3), 80 kW (at 660 to 690V AC 50/60 Hz AC-3), 65 kW (at 1000V AC 50/60 Hz AC-3), 18.5 kW (at 400V AC 50/60 Hz AC-4), 30 kW (at 220 to 230V AC 50/60 Hz AC-3e), 55 kW (at 380 to 400V AC 50/60 Hz AC-3e), 59 kW 415 to (at 440V AC 50/60 Hz AC-3e), 75 kW (at 500V AC 50/60 Hz AC-3e), 80 kW (at 660 to 690V AC 50/60 Hz AC-3e), 65 kW (at 1000V AC 50/60 Hz AC-3e)
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Rated Short-Time Withstand Current
250 A (at 40°C for 10 min Power Circuit), 550 A (at 40°C for 1 min Power Circuit), 950 A (at 40°C for 10 s Power Circuit), 1100 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Fuse Amps
250 A (Type 1 Power Circuit), 200 A (Type 2 Power Circuit), 10 A (Signalling Circuit)
Mechanical Durability
8 Mcycles
Impulse Withstand Voltage
8 kV
Operating Time
20 to 35 ms (Closing), 40 to 75 ms (Opening)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Control Circuit Voltage Limits
Operational DC: 0.75 to 1.2 Uc (at -40 to 55°C), 1 to 1.2 Uc (at 55 to 70°C); Drop-Out DC: 0.15 to 0.4 Uc (at -40 to 70°C)
Operating Speed
1200 cycles per hr
Application
Motor Control, Resistive Load
Tightening Torque
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Rated Breaking Capacity
1100 A @ 440V
Embedded Surge Suppressor
Yes
Horsepower @ Three Phase - 240V AC
40 hp
Full Load Current - Inductive
115 A
Mechanical Operating Durability
8,000,000
Full Load Current - Resistive
200 A
Horsepower @ Single Phase - 240V AC
1 hp
Resistance Properties
Fire Resistant, Insulation Resistant
Mounting Style
DIN Rail, Plate
Includes Auxiliary Contacts
Yes
Horsepower @ Three Phase - 600V AC
100 hp
Horsepower @ Three Phase - 208V AC
30 hp
Electrical Operating Durability
800,000, 950,000
Number of Normally Open Main Contacts
3
Minimum Operating Temperature
-40 Degrees F
Maximum Voltage Rating
1000V AC
Maximum Operating Temperature
140 Degrees F
Horsepower @ Three Phase - 480V AC
75 hp
NEMA Enclosure Rating
No Enclosure
Conventional Free Air Thermal Current
200 A (at 60°C Power Circuit)