- Item
- IEC Magnetic Contactor
- Auxiliary Contact Form
- 1NC/1NO
- Coil Voltage
- 24V DC
- Number of Poles
- 3
- Full Load Amps-Inductive
- 32 A
- Full Load Amps-Resistive
- 50 A
- Reversing Capability
- Reversing
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 2
- Standards
- BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
- HP @ 3 Phase - 575V
- 30 hp
- Reversing
- Yes
- HP @ 1 Phase - 230V
- 5
- Enclosure NEMA Rating
- No Enclosure
- Series
- TeSys Deca
- Switching Voltage
- 17 V (Signalling Circuit)
- Vibration Resistance
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Features
- Built-In Bi-Directional Peak Limiting Diode Suppressor; Preassembled with Reversing Power Busbar
- Switching Current
- 5 mA (Signalling Circuit)
- Application
- Motor Control, Resistive Load
- Overvoltage Category
- CAT III
- Fuse Amps
- 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit)
- Impedance
- 2 mOhm
- IP Rating
- IP20
- Operating Speed
- 3600 cycles per hr
- Non-Overlap Time
- 1.5 ms
- Mechanical Durability
- 30 Mcycles
- Signalling Circuit Frequency
- 25 to 400 Hz
- Rated Short-Time Withstand Current
- 60 A (at 40°C for 10 min Power Circuit), 138 A (at 40°C for 1 min Power Circuit), 260 A (at 40°C for 10 s Power Circuit), 430 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
- Max. Operating Watts
- 7.5 kW (at 220 to 230V AC 50 Hz), 15 kW (at 380 to 400V AC 50 Hz), 15 kW (at 415 to 440V AC 50 Hz), 18.5 kW (at 500V AC 50 Hz), 18.5 kW (at 660 to 690V AC 50 Hz)
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Fire Rating
- UL 94 V1
- Control Circuit Voltage Limits
- Drop-Out DC: 0.1 to 0.25 Uc (at -40 to 70°C), Operational DC: 0.7 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C)
- Shock Resistance
- 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
- Rated Insulation Volts
- 600/690V
- Electrical Durability
- 1.65 Mcycles (32 A, AC-3, Less than 440 V); 1.4 Mcycles (50 A, AC-1, Less than 440 V)
- Environmental Attributes
- Mercury Free, PVC Free, Pollution Degree 3
- Operating Time
- 53.55 to 72.45 ms (Closing), 16 to 24 ms (Opening)
- Tightening Torque
- 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
- Net Weight
- 1.127 kg
- Includes Protective Cover
- Yes
- Impulse Withstand Voltage
- 6 kV
- Rated Making Capacity
- 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit)
- Rated Breaking Capacity
- 550 A @ 440V
- Horsepower @ Single Phase - 120V AC
- 2 hp
- Includes Auxiliary Contacts
- Yes
- Horsepower @ Single Phase - 240V AC
- 5 hp
- Frequency
- 50/60 Hz
- Contactor Style
- IEC
- Horsepower @ Three Phase - 480V AC
- 20 hp
- Horsepower @ Three Phase - 208V AC
- 7 1/2 hp
- Mechanical Operating Durability
- 30,000,000
- Electrical Operating Durability
- 1,400,000, 1,650,000
- Embedded Surge Suppressor
- Yes
- Full Load Current - Resistive
- 50 A
- Resistance Properties
- Fire Resistant, Insulation Resistant
- NEMA Enclosure Rating
- No Enclosure
- Minimum Operating Temperature
- -40 Degrees F
- Horsepower @ Three Phase - 240V AC
- 10 hp
- Horsepower @ Three Phase - 600V AC
- 30 hp
- Full Load Current - Inductive
- 32 A
- Maximum Voltage Rating
- 690V AC
- Number of Normally Open Main Contacts
- 3
- Maximum Operating Temperature
- 140 Degrees F
- Mounting Style
- DIN Rail, Plate
- Pollution Degree
- 3
- Product Name
- TeSys D; TeSys Deca
- Climatic Withstand
- IACS E10; IEC 60947-1 Annex Q category D
- Protective Treatment
- TH IEC 60068-2-30
- Rated Operational Voltage
- Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
- Device Presentation
- Preassembled with reversing power busbar
- Conventional Free Air Thermal Current
- 10 A (at 140°F (60°C)) for signalling circuit; 50 A (at 140°F (60°C)) for power circuit
- Fire Resistance
- 1562°F (850°C) IEC 60695-2-1
- Rated Operational Current
- 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
- Hold-In Power Consumption in W
- 5.4 W 68°F (20°C)
- Ambient Air Temperature For Operation
- -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
- Auxiliary Contacts Type
- Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
- Operating Altitude
- 0 to 9842.52 ft (0 to 3000 m)
- Utilisation Category
- AC-1; AC-3; AC-3e
- Front Cover
- With
- Time Constant
- 28 ms
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Contactor Application
- Motor control; Resistive load
- Ambient Air Temperature For Storage
- -76 to 176°F (-60 to 80°C)
- Control Circuit Type
- DC standard
- Mechanical Robustness
- Vibrations contactor open2 Gn, 5 to 300 Hz; Vibrations contactor closed4 Gn, 5 to 300 Hz; Shocks contactor closed15 Gn for 11 ms; Shocks contactor open8 Gn for 11 ms
- Interlocking Type
- Mechanical
- Maximum Operating Rate
- 3600 cyc/h 140°F (60°C)
- Power Dissipation Per Pole
- 2 W AC-3; 5 W AC-1; 2 W AC-3e
- Inrush Power in W
- 5.4 W 68°F (20°C)
- Pole Contact Composition
- 3 NO