IEC Miniature Magnetic Contactor, 1NO, 208V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1K0910L7

  • Zoro # G2836626


product price: 
$
88.19
/ea

Key Features

Auxiliary Contact Form
1NO
Coil Voltage
208V AC
Number of Poles
3
Full Load Amps-Inductive
9 A
Full Load Amps-Resistive
20 A
See all product information
Unlock 30-day payment terms
Unlock 30-day payment terms
Business customers can apply for Net 30—no fees, no interest, fast approval. Terms apply.
Create Account
Get 10% off your order
Get 10% off your order
Sign up for our email list and receive your promo code via email.

Specifications

Details

MFR #
LC1K0910L7
Zoro #
G2836626
UPC #
785901720034
Country of Origin
Indonesia
Item
IEC Miniature Magnetic Contactor
Auxiliary Contact Form
1NO
Coil Voltage
208V AC
Number of Poles
3
Full Load Amps-Inductive
9 A
Full Load Amps-Resistive
20 A
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
CSA, UKCA, UL Listed
HP @ 3 Phase - 575V
5 hp
Enclosure NEMA Rating
No Enclosure
Reversing
No
HP @ 1 Phase - 230V
1-1/2
Series
TeSys K
Impedance
3 mOhm
Signalling Circuit Frequency
Less Than 400 Hz
Switching Voltage
17 V (Signalling Circuit)
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free
Fuse Amps
25 A (Power Circuit), 10 A (Signalling Circuit)
Fire Rating
UL 94 V1, NF F 16-101, NF F 16-102
Shock Resistance
10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Operating Speed
3600 cycles per hr
Control Circuit Voltage Limits
Operational: 0.85 to 1.1 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Overvoltage Category
CAT III
Inrush VA
30 VA
Switching Current
5 mA (Signalling Circuit)
Electrical Durability
1.3 Mcycles 9 A AC-3 Less than or Equal to 440 V; 1.3 Mcycles 9 A AC-3e Less than or Equal to 440 V; 0.16 Mcycles 20 A AC-1 Less than or Equal to 690 V; 0.02 Mcycles 54 A AC-4 Less than or Equal to 440 V
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Mechanical Durability
10 Mcycles
Rated Breaking Capacity
110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
Max. Operating Watts
2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW 380 to (at 415V AC 50/60 Hz AC-3), 4 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 415V AC 50/60 Hz AC-3e), 4 kW (at 440V AC 50/60 Hz AC-3e), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Watts Loss
1.3W
Operating Time
10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
Rated Making Capacity
110 A
Hold VA
4.5 VA
Application
Motor Control, Resistive Load
NEMA Enclosure Rating
No Enclosure
Frequency
50/60 Hz
Phase
Three
Horsepower @ Three Phase - 600V AC
5 hp
Resistance Properties
Insulation Resistant
Full Load Current - Resistive
20 A
Horsepower @ Three Phase - 480V AC
5 hp
Number of Normally Open Main Contacts
3
Horsepower @ Three Phase - 240V AC
3 hp
Includes Auxiliary Contacts
Yes
Horsepower @ Single Phase - 240V AC
1 1/2 hp
Mounting Style
DIN Rail
Maximum Voltage Rating
480V AC
Horsepower @ Single Phase - 120V AC
1/2 hp
Embedded Surge Suppressor
No
Full Load Current - Inductive
9 A
Horsepower @ Three Phase - 208V AC
2 hp
Contactor Style
IEC
Rated Operational Current
9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Protective Treatment
TC IEC 60068; TC DIN 50016
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Auxiliary Contacts Type
Instantaneous 1 NO
Mechanical Robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Conventional Free Air Thermal Current
20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Device Application
Control
Control Circuit Type
AC 50/60 Hz
Utilisation Category
AC-3; AC-3e; AC-1; AC-4
Non Overlap Distance
0.02 in (0.5 mm)
Inrush Power in VA
30 VA (at 68°F (20°C))
Operating Altitude
6561.68 ft (2000 m) without derating
Contactor Application
Motor control; Resistive load
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz
Control Circuit Voltage
200 to 208 V AC 50/60 Hz
Heat Dissipation
1.3 W
Maximum Operating Rate
3600 cyc/h
Impulse Withstand Voltage
8 kV
Pole Contact Composition
3 NO

Description

The IEC Miniature Magnetic Contactor is a compact, electrically actuated switch rated for operation within the specified voltage and current ranges per IEC standards. It is a three-pole, non-reversing device with three normally open main contacts and one normally open auxiliary contact, energized by a 208 V AC coil. Rated for use with motors and resistive loads within specified parameters. Compatible with DIN-rail mounting as per product specifications, with screw-clamp terminals.

Coil voltage: 208 V AC; Control circuit: AC 50/60 Hz; Poles/Main contacts: 3P, 3 NO; Auxiliary contact: Instantaneous 1 NO

  • Application: suitable for motor control and resistive load applications within specified fuse ratings as defined by IEC 60947/VDE 0660 standards
  • Maximum voltage rating: rated for operation up to a maximum of 480 V AC under specified conditions
  • Embedded surge suppressor: does not include an integrated surge suppression device; compatibility with external surge protection should be verified based on application needs
  • Enclosure: designed for installation in enclosures compliant with applicable safety standards
  • Mounting: DIN Rail; Terminals: Screw Clamp; Series: TeSys K
  • Rated operational current: 9 A (AC-3 up to 440 V), 20 A (AC-1 up to 690 V)
  • Full load amps: capable of handling full load currents as specified when operated within the recommended parameters
  • Inrush/hold power: Inrush 30 VA; Hold-in 4.5 VA
  • Dimensions: Width 1.73 in; Height 1.73 in; Depth 1.97 in
  • Certifications: UL Listed; CSA; CE; UKCA; CB Scheme; CCC; EAC
  • Ratings & reviews