- MFR #
- 8501XO20V03
- Zoro #
- G1081674
- UPC #
- 785901536987
- Country of Origin
- Korea, Republic of
- Item
- NEMA Control Relay
- Coil Volts
- 240V AC
- Hz
- 60
- Power Consumption - Relay
- 23.0 VA
- Features
- Contact Conversion without Removing Terminal Screws or Wires, Plug-in Contact Cartridges for Easy Contact Conversion and Replacement, Replaceable Coil, Self-Lifting Pressure Wire Connectors, Straight-Through Wiring
- Contact Amp Rating (Resistive)
- 10A
- Contact Form
- 2NO
- Item - Relay
- NEMA Style Control Relay
- Mounting
- Panel
- Response Time
- 15 msec (Pick-Up Time), 16 msec (Drop-Out Time)
- DC Contact Rating - Relay
- 5A @ 125/250V
- Accessory Group
- A
- Mounting - Relay
- Surface
- AC Contact Rating - Relay
- 10A @ 120/240/480/600V
- Standards
- CSA Certified, RoHS Compliant, UL Listed
- Contact Form - Relay
- (2) SPST-NO
- Number of Pins - Relay
- 6
- Hz - Electrical
- 60 Hz
- Contact Material
- Silver Cadmium Oxide
- Relay Type
- control
- Inrush Power In Va
- 148-148 VA 60 Hz || 143-143 VA 50 Hz
- Tightening Torque
- control circuit 1.02-1.36 N.m screw terminals
- Mounting Support
- panel
- Rated Breaking Capacity
6 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 3 A 240 V AC inductive control circuit UL 508 || 1.5 A 480 V AC inductive control circuit UL 508 || 1.2 A 600 V AC inductive control circuit UL 508 || 10 A <= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301 to 600 V DC inductive control circuit UL 508 || 4 A 125 V DC resistive control circuit UL 508
- Operating Time
- 15 ms - pick-up || 16 ms - drop-out
- Ambient Air Temperature For Operation
- -40-160 °F
- Awg Gauge
- AWG 18 to AWG 12 copper
- [Icm] Rated Short-Circuit Making Capacity
60 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 30 A 240 V AC inductive control circuit UL 508 || 15 A 480 V AC inductive control circuit UL 508 || 12 A 600 V AC inductive control circuit UL 508 || 10 A <= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301 to 600 V DC inductive control circuit UL 508 || 4 A 125 V DC inductive control circuit UL 508
- Contacts Type And Composition
- 2 NO 2 standard contact cartridges
- Product Certifications
- CSA LR60905 class 3211 03 || UL listed file E78403 CCN NKCR
- Hold-In Power Consumption In Va
- 23-23 VA 60 Hz || 25-25 VA 50 Hz
- Control Circuit Voltage Limits
- operational 0.85 to 1.1 Uc AC 50/60 Hz
- Product Or Component Type
- relay
- Line Rated Current
- 10 A AC || 5 A DC
- [Uc] Control Circuit Voltage
- 220 V AC 50 Hz || 240 V AC 60 Hz
- Electrical Connection
- Screw Clamp
- Contact Rating (DC)
- 0.2 A @ 301-600V, 0.55 A @ 250V, 0.8 A @ 250V, 1.1 A @ 125V, 4 A @ 125V
- Number of Pins
- 6
- Power Consumption
- 23 VA
- Weight
- 2.0 lbs.
- Frequency
- 50/60 Hz
- Contact Rating (AC)
- 10 A @ 600V
- Mounting Style
- Surface
- Minimum Operating Temperature
- -40 Degrees F
- Input Voltage
- 220/240V AC
- Maximum Operating Temperature
- 160 Degrees F
- Compatible with Series
- 8501 Type X Latching Control Relays
- Current Rating
- 10 A
- Coil Voltage
- 220/240V AC
- Relay Style
- NEMA