- MFR #
- XCSLF3737333
- Zoro #
- G4403987
- UPC #
- 785901965510
- Country of Origin
- Indonesia
- Item
- Safety Interlock Switch
- Style
- Metal Locking
- Series
- XCSLF
- AC Contact Rating
- 0.75 A @ 240 V
- DC Contact Rating
- 0.55 A @ 24 V
- Solenoid Voltage
- 120 V AC
- Contact Form
- 1NO/2NC
- Connection Type
- 1/2 in NPT Conduit
- IP Rating
- IP66, IP67
- Operating Temp. Range
- -13 Degrees to 140 Degrees F
- Description/Special Features
- 300 Solenoid Contacts
- Standards
- CSA C22.2 No 14, EN 1088/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 62061, EN/ISO 13849-1, UL 508
- Operating Force
- 4.5 lb Unlocked, 517 lb Locked
- Body Material
- Zamak
- Head Material
- Zamak
- Features
- 300 Solenoid Contacts
- Material
- metal
- Electrical Connection
- 1/2 in NPT Conduit
- Shock Resistance
- 10 gn 11 ms IEC 60068-2-27
- Mechanical Durability
- 1000000 cycles
- Head Type
- key operated turret head
- Vibration Resistance
- 5 gn 10-500 Hz)IEC 60068-2-6
- Operating Temperature - Minimum
- -13 Degrees F
- Resistance Properties
- Shock Resistant, Vibration Resistant
- Actuator Material
- Metal
- Operating Temperature - Maximum
- 158 Degrees F
- Actuating Key Type
- Pivoting, Flat
- Mechanical Operating Durability
- 1,000,000
- Circuitry Action
- Slow Action
- Signalling Circuit Type
- AC
- Solenoid Contacts Type And Composition
- 2 NC + 1 NO slow-break, break before make)
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV EN/IEC 60947-5-1
- Local Signalling
- for actuator withdrawn 1 LED (orange) || for actuator inserted and locked 1 LED (green)
- Supply Frequency
- 50/60 Hz
- Protective Treatment
- TC
- Minimum Actuator Force For Extraction
- 20 N
- Maximum Actuator Forcible Withdrawal Rtc
- 3000 N
- Signalling Circuit Voltage
- 120 V
- Component Name
- XCSLF
- Minimum Switching Current
- 10 mA at 20°C
- Maximum Load Current
- <= 15 A
- Ambient Air Temperature For Storage
- -40-70°C
- Supply Voltage Type
- AC/DC
- [Ithe] Conventional Enclosed Thermal Current
- 4A
- Product Certifications
- TUV || UL || CSA
- Electromagnet Interlocking
- locking on de-energisation and unlocking on energisation of solenoid
- Ip Degree Of Protection
- IP66 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 || IP67
- Resistance To Mechanical Impact
- 9.6 J against the partition || 6.4 J without partition
- Ambient Air Temperature For Operation
- -25-60°C
- Maximum Operating Rate
- 10 cyc/mn for maximum durability
- Short-Circuit Protection
- 4 A cartridge fuse gG (gl) || 6 A fast blow
- Electrical Shock Protection Class
- class I EN/IEC 61140
- Minimum Actuation Speed
- 0.01 m/s
- Load Factor
- 1
- Number Of Poles
- 3
- Cable Entry
- 3 entries tapped 1/2" NPT
- [Us] Rated Supply Voltage
- 120 V - 15...10 %
- Positive Opening
- with NC contact
- Design
- slim
- Product Or Component Type
- safety switch
- Safety Level
- can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 EN/IEC 61508
- Contacts Type And Composition
- 2 NC + 1 NO
- Minimum Switching Voltage
- 17 V
- [Ie] Rated Operational Current
- 0.55 A 24 V, DC-13, R300 EN/IEC 60947-5-1 || 0.75 A 240 V, AC-15, C300 EN/IEC 60947-5-1
- Maximum Actuation Speed
- 0.5 m/s
- Contact Operation
- slow-break, break before make
- [Ui] Rated Insulation Voltage
- 300 VUL 508 || 300 VCSA C22.2 No 14 || 250 V 3)EN/IEC 60947-1