Vacuum Pump, 10 cfm, 15 micron, 120V AC

  • Mfr # 0564 5653 01
  • Zoro # G812425326
product price: 
$
1,039.99
/ea
Free Shipping & Returns

Key Features

End Vacuum
15 micron
Intake Male SAE Flare
1/4 SAE, 3/8 SAE,1/2 SAE
Application
Commercial, Industrial, Residential
Type
Rotary vane pump, two-stage
Includes
Oil
See all product information
Unlock 30-day payment terms
Unlock 30-day payment terms
Business customers can apply for Net 30—no fees, no interest, fast approval. Terms apply.
Create Account
Get 10% off your order
Get 10% off your order
Sign up for our email list and receive your promo code via email.

Specifications

Details

MFR #
0564 5653 01
Zoro #
G812425326
UPC #
4029547026614
Country of Origin
China
End Vacuum
15 micron
Intake Male SAE Flare
1/4 SAE, 3/8 SAE,1/2 SAE
Application
Commercial, Industrial, Residential
Type
Rotary vane pump, two-stage
Includes
Oil
Special Features
Fully automated evacuation process with integrated holding test. Can be safely used even with, flammable class A3 and A2L refrigerants, Easy oil change and sight glass for quick assessment of the oil level, Non-return valve to prevent loss of vacuum in the event of power failure
Finish
Black
Reservoir Port Connection Type
NPT
Horsepower
3/4 hp
Includes Oil Mist Filter
Oil Mist Filter Included
Voltage
120V AC
Oil Capacity
18.4 oz
Inlet 2 Port Connection Type
SAE
Motor Type
Brushless DC
Operating Temperature - Minimum
41 Degrees F
Number of Stages
Two-Stage
Item
Vacuum Pump
Inlet 3 Port Connection Type
SAE
Ultimate Vacuum
15 micron
Includes Vacuum Gauge
Gauge Not Included
Inlet 1 Port Connection Gender
Male
Displacement
10 cfm
Inlet 1 Port Connection Thread Direction
Right-Hand
Weight
28.7 lb
Plug Configuration
5-15P
Battery Recharge
Not Rechargeable
Inlet 2 Port Connection Thread Direction
Right-Hand
Includes Gas Ballast
Gas Ballast Included
Frequency
60 Hz
Standards
ISO VG 46
Includes Sightglass
Sightglass Included
Drain Port Connection Type
SAE
Inlet 2 Port Connection Gender
Male
Drain Port Connection Gender
Female
Reservoir Port Connection Gender
Female
Connectivity
Bluetooth
Inlet 1 Port Connection Type
SAE
Reservoir Port Connection Thread Direction
Right-Hand
Body Material
Metal
Series
565i
Number of Inlet Ports
3
Drain Port Connection Thread Direction
Right-Hand
Includes Hoist Clip
Hoist Clip Not Included
App Compatibility
testo Smart
A2L Compatibility
A2L Compatible
Operating Temperature - Maximum
104 Degrees F
Includes Isolation Valve
Isolation Valve Included
Calibration Certificate Type
Available Separately
Drive Type
Direct Drive
Power Source
Plug-In
Warranty
2 yr
Inlet 3 Port Connection Gender
Male
Product Type
Vacuum Pump
Inlet 3 Port Connection Thread Direction
Right-Hand
Mobility
Handle
Current
3.3 A

Dimensions

Overall Width
5.9 in
Drain Port Connection Size
3/8
Inlet 1 Port Connection Size
1/4 in
Overall Height
12.4 in
Inlet 2 Port Connection Size
3/8 in
Cord Length
4 ft
Length
14.8 in
Reservoir Port Connection Size
1/2 in
Inlet 3 Port Connection Size
1/2 in
Overall Length
14.8 in

Description

The new testo 565i vacuum pump performs refrigeration system and heat pump evacuations completely automatically. Once the desired vacuum target value is reached, pumping is automatically stopped and a vacuum hold test is initiated at the same time. Foreign gases and moisture can thus be removed safely, and data relating to the system's leak-tightness stored. The data logging function ensures complete documentation. This allows evacuations to run completely independently - for maximum accuracy and efficiency. Configuration, monitoring of live readings and sending of the measurement report are all easily controlled via the free testo Smart App. This allows you to remain flexible and saves valuable time. To ensure perfect interaction between workflows, when the testo 565i is switched on, it automatically establishes a Bluetooth connection to the Testo measuring instruments and also the Smart App. The pump also guarantees maximum safety at all times thanks to its compatibility with A2L and A3 refrigerants. Maximum convenience is guaranteed by the simple oil change mechanism and the sight glass for quick assessment of the oil level, along with the ergonomic handle. To ensure high reliability, the built-in non-return valve provides effective protection against loss of vacuum, even in the event of unexpected power failures, and offers an extra layer of safety for uninterrupted operation.


  • Fully automated evacuation process with integrated holding test when used in combination with the testo 552i vacuum probe
  • Can be safely used even with flammable class A3 and A2L refrigerants
  • One app for everything: Configure and monitor measurements and manage data with the testo Smart App
  • Easy oil change and sight glass for quick assessment of the oil level
  • Non-return valve to prevent loss of vacuum in the event of power failure
  • Perfect interaction between workflows thanks to full connectivity to the entire Testo refrigeration portfolio

Ratings & reviews