UPS Type
Online Double Conversion
Input Voltage
120 V, 208 V, 240 V
Output Voltage
120 V, 208 V, 240 V
Backup Time (Half/Full Load)
12 min/5 min
Medical Grade
Not Medical Grade Approved
Output Voltage - UPS Systems
112V AC, 208V AC, 240V AC
Ports
DB9 Serial, EPO, USB
VA Rating - UPS Systems
16.0 kVA
NEMA Receptacle Configuration
No Configuration
Watts - UPS Systems
11.2 kW
Outlet Type - UPS Systems
Hardwired
Mounting - UPS Systems
Rack
Includes
(4) Post Rack Mount Installation Brackets, BP192V18-4U External Battery Pack, SUPDMB16KHW Detachable PDU with Manual Bypass Switch
Input Voltage - UPS Systems
112V AC, 208V AC, 240V AC
Special Features
Hot-Swappable Batteries
Automatic Volts Regulation
Yes
Fax/Modem Line Protection
No
Input Connection
Hardwired
Battery Type
Valve Regulated Lead Acid (VRLA)
UPS Housing Material
Steel
Front Panel LCD Display
Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats
UPS Input Connection Type
Hardwire
Output Capacity Details
16,000VA, 11,200W (240V) / 13,860VA, 11,200W (208V); Supports up to 105% load continuously in double conversion mode, 106 to 125% for 3 minutes, 126 to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support equipment directly from mains power; Double conversion mode is automatically restored as the overload is cleared
Rated input current (Maximum Load)
68A
Frequency Compatibility
60 Hz
Relative Humidity
0 to 95%, non-condensing
Output Voltage Regulation (Battery Mode)
+/- 3%
Network Management Cards
SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
AC Economy Mode Efficiency Rating (100% Load)
0.94
Output Receptacles
Hardwire
Low Voltage Transfer to Battery Power (Setpoint)
65V (L1-N:L2-N)
UPS AC Suppression Joule Rating
3620
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement
Cold Start (Startup in Battery Mode During a Power Failure)
Cold-start operation supported
Output kVA Capacity (kVA)
16
AC Economy Mode BTU / Hr. (Full Load)
2438
UPS Certifications
Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
Output Receptacle Details
Supports North American 208/120V or 240/120V split-phase output (L1, L2, N, G)
PowerAlert Software
For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
EMI / RFI AC Noise Suppression
Yes
Output Voltage Regulation (Line Mode)
+/- 3%
Battery Recharge Rate (Included Batteries)
Less than 6 hours from 10% to 80% (typical, full load discharge)
Undervoltage Correction
Corrects undervoltages to 65V (measured L1-N : L2-N)
DC System Voltage (VDC)
192
High Availability UPS Features
Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch
Network Monitoring Port Description
RS232 and contact closure communications are supported on one DB9 port
Full Load Runtime (min.)
5 min. (11,200w)
Audible Alarm
Unique audible alarms for all major UPS, environmental and power conditions (see manual)
LED Indicators
6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
Nominal Voltage Details
240/120V or 208/120V split phase output
Operating Elevation (ft.)
0-3000m (0 to 10,000 ft.)
Voltage Regulation Description
+/-3% output voltage regulation in online, double-conversion mode
Output kW Capacity (kW)
11.2
Output Watt Capacity (Watts)
11200
Crest Factor
0.125694444444444
Battery Mode BTU / Hr. (Full Load)
4248
Communications Cable
USB and DB9 cabling included
Overvoltage Correction
Corrects overvoltages to 140 (measured L1-N : L2-N)
Output AC Waveform (AC Mode)
Pure Sine wave
External Battery Pack Compatibility
BP192V18-4U
Recommended Electrical Service
70A 208/240-120 Split Phase (L1, L2, N, G); 4 AWG wiring recommended
Output AC Waveform (Battery Mode)
Pure Sine wave
Nominal Input Voltage(s) Supported
120/208V (Split phase L1,L2,N,G); 120/240V (Split phase L1,L2,N,G)
Operating Elevation (m)
0-3000 m
Audible Noise
60 dBA at front side 1 meter
UPS AC Suppression Response Time
Instantaneous
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
Included Mounting Accessory Description
2 sets of adjustable 4 post rack rails included
Individually Controllable Load Banks
No
High Voltage Transfer to Battery Power (Setpoint)
140V (L1-N:L2-N)
Output Volt Amp Capacity (VA)
16000
AC Mode BTU / Hr. (Full Load)
5717
Alarm Cancel Operation
Alarm cancel switch
Primary Form Factor
Rackmount
Nominal Output Voltage(s) Supported
120V; 208V; 240V
Installation Form Factors Supported with Optional Accessories
2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)
Battery Replacement Description
Hot-swappable, user replaceable external battery packs
Output Voltage Regulation (Economy Line Mode)
+/- 10%
Half Load Runtime (min.)
12 min. (5600w)
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
UPS Input Connection Description
4 wire split-phase input (L1, L2, N, G)
Installation Form Factors Supported with Included Accessories
4 post 19 inch rackmount
Expandable Battery Runtime
Supports extended runtime with optional external battery packs
Transfer Time (Economy Mode)
2 milliseconds typical in optional economy mode
Communications Interface
USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
Software Included
PowerAlert Software
Typical Battery Recharge Time
6 Hour
Package Contents
SmartOnline SU16000RT4UHW 16kVA Tower/Rack-mountable UPS, 16kVA/16,000 VA UPS power module in 4U rackmount housing, Detachable hardwire input & output backplate with manual bypass switch, External 4U battery pack, 4-post rackmount installation brackets
Backup/Run Time (Full Load)
5 Minute
Product Name
SmartOnline SU16000RT4UHW 16kVA Tower/Rack-mountable UPS
Network Management
SNMP Manageable
Plug/Connector Type
Hardwired
Additional Information
Ideal for protection of sensitive electronics in any application calling for upright tower or 19-in. rackmount UPS protection, Common applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems, Output volt amp capacity (VA): 16,000 (240V)/13860 (208V)
Backup/Run Time (Half Load)
12 Minute
Receptacle Type
Hardwired
Product Type
Double Conversion Online UPS
Runtime Half Load (min.)
12 min. (5600w)
Package Includes
SU16000RT4UPM UPS Power Module;BP192V18-4U External battery pack;SUPDMB16KHW Detachable PDU with manual bypass switch;4-post rackmount installation brackets
Output Capacity (Watts)
11200
UPS Applications
Mission Critical Applications
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load
4248
Runtime Full Load (min.)
5 min. (11,200w)
Output Capacity (VA)
16000
Manufacturer Warranty
2 yr
Surge Suppression Rating
3,620 J
Run Time - Half Load
12 min
Operating Temperature - Minimum
32 Degrees F
External Battery Compatible
External Battery Pack Compatible
Plug Configuration
Hardwired
External Battery Pack Part Number
BP192V18-4U
Output Ports Included
DB9 Serial, EPO, USB
Number of Outlets - Surge Only
4
Input Current - Maximum
68 A
Automatic Voltage Regulation
Includes Automatic Voltage Regulation
Includes Battery
Battery Included
Transfer Time - Maximum
0 msec
Operating Temperature - Maximum
104 Degrees F
Run Time - Full Load
5 min
Power Rating - Apparent
16 kVA
Receptacle Configuration
Hardwired
Battery Chemistry
Valve Regulated Lead Acid
Number of Outlets - UPS
4
Battery Recharge Time
6 hr
Power Rating - Real
11.2 kW