Backup Time (Half/Full Load)
11.1 min/3 min
Outlet Type
(3) Surge, (3) UPS/Surge
Fax/Modem Line Protection
No
NEMA Plug Configuration
5-15p
Watts - UPS Systems
375.0 W
NEMA Receptacle Configuration
5-15R
Outlet Type - UPS Systems
(3) Surge, (3) UPS/Surge
Green Environmental Attribute
Product Contributes To Reducing Energy Consumption
Output Voltage - UPS Systems
120V AC
Mounting - UPS Systems
Tower
Transfer Time
3 msec from Battery to AC, 6 msec from AC to Battery
Input Voltage - UPS Systems
120V AC
Special Features
Advanced AVR Corrects Brownouts and Overvoltages, Pure Sine Wave Output
Standards
CSA, FCC Part 15 Category B (EMI), NOM, ROHS (Restriction of Hazardous Substances), UL 1778
VA Rating - UPS Systems
600.0 VA
Automatic Volts Regulation
No
Green Certification or Other Recognition
UL1778CC Part 15 Category B (EMI), RoHS
Backup/Run Time (Full Load)
3.30 Minute/11.10 Minute
Capacity - Batteries
600 VA/375 W
Input Connection
6 ft Cord with NEMA 5-15P Plug
Battery Type
Valve Regulated Lead Acid (VRLA)
Half Load Runtime (min.)
11.1 min. (190 watts)
Output Watt Capacity (Watts)
375
WatchDog Compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
Recommended Electrical Service
15A 120V
UPS Output Receptacles (Surge Suppression Only)
3 UPS outlets, 3 surge-only outlets
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)
Communications Cable
USB cable included
Battery Recharge Rate (Included Batteries)
Less than 9 hours from 10% to 90%
UPS AC Suppression Joule Rating
252
Relative Humidity
0 to 95%, non-condensing
UPS AC Suppression Response Time
Instantaneous
Rated input current (Maximum Load)
10A Max (UPS and surge-only loads combined)
PowerAlert Software
For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
High Voltage Transfer to Battery Power (Setpoint)
139V
Communications Interface
USB (HID enabled)
Nominal Input Voltage(s) Supported
120V AC
Output Receptacles
(6) 5-15R
Installation Form Factors Supported with Included Accessories
Tower
Output Voltage Regulation (Battery Mode)
+/- 5%
Output AC Waveform (Battery Mode)
Pure Sine wave
Output AC Waveform (AC Mode)
Sine wave
Battery Replacement Description
Hot-swappable, user replaceable batteries
High Availability UPS Features
Hot swappable batteries
Network UPS Tools Compatibility
NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation
Battery Access
Battery access door
Cold Start (Startup in Battery Mode During a Power Failure)
Cold-start operation supported
Nominal Voltage Details
120v nominal output in battery mode
Hot-Swap PDU options
PDUB15 (2U / 8 5-15R outlets)
EMI / RFI AC Noise Suppression
Yes
LED Indicators
LINE POWER (green), INVERTER MODE (yellow), OVERLOAD (red), REPLACE BATTERY (red)
UPS Input Connection Type
5-15P; Right-Angled
Audible Alarm
Audible alarm indicates power failure and overload conditions
Nominal Output Voltage(s) Supported
110V; 115V; 120V
AC Mode Efficiency Rating (100% Load)
0.97
Full Load Runtime (min.)
3.3 min. (375 watts)
Low Voltage Transfer to Battery Power (Setpoint)
99V
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Internal UPS Replacement Battery Cartridge
RBC51
Individually Controllable Load Banks
No
DC System Voltage (VDC)
12
AC Mode BTU / Hr. (Full Load)
33
Output Volt Amp Capacity (VA)
600
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Primary Form Factor
Tower
Alarm Cancel Operation
Power-fail alarm can be silenced during a power failure using alarm-cancel switch; alarm can be permanently disabled via PowerAlert software interface
Frequency Compatibility
60 Hz
Load Capacity
600 VA/375 W
Backup/Run Time (Half Load)
11.10 Minute
Receptacle Detail
3 x NEMA 5-15R
Certifications & Standards
UL1778, CC Part 15 Category B (EMI)
Plug/Connector Type
NEMA 5-15P
Product Name
BC600SINE 600 VA Tower UPS
Package Contents
BC600SINE 600 VA Tower UPS, PowerAlert Software CD, USB Cable, Owner's Manual
Typical Battery Recharge Time
9 Hour
Software Included
PowerAlert Software
Output Capacity (Watts)
375
Package Includes
BC600SINE UPS System;USB Cable;Owner's manual
UPS Applications
Computer/Peripherals;Audio/Video; Retail/Point of Sale; Hospitality
Runtime Full Load (min.)
3.3 min. (375W)
Product Certifications
CSA (Canada); NOM (Mexico); UL 1778
Runtime Half Load (min.)
11.1 min. (188W)
Product Compliance
FCC Part 15 Class B (USA)