Booster Pump, 2 hp, 120/240V AC, 1 Phase, 1 in NPT Inlet Size, 11 Stage, 150 psi Max Pressure

  • Mfr # PB2711A201

  • Zoro # G4729514


product price:  $1,467.90
/ea
Free Shipping & Returns

Key Features

Booster Pump Type
Multi-Stage Booster Pump
HP - Pumps
2 hp
Voltage - Pumps
120/240V AC
Phase - Pumps
1
Inlet Size - Pumps
1 in NPT
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Real support from real people
Contact our U.S. based team

Specifications

Product Information

MFR #
PB2711A201
Zoro #
G4729514
UPC #
054757044404
Country of Origin
United States

Dimensions

Inlet Size - Pumps
1 in NPT
Outlet Size - Pumps
1 in NPT
Max. Dia. Solids
clear water
Width
6 1/2 in
Manufacturers Warranty Length
1 yr
Height
9 in
Length
27 1/2 in
Overall Width
6.5 in
Overall Height
9 in
Overall Length
27.5 in
Solid Diameter (Maximum)
0 in
Intake Size
1 in
Manufacturer Warranty Length
1 yr
Compatible Intake Pipe Size
1 in
Compatible Discharge Pipe Size
1 in
Inlet Diameter
1 in
Solids Diameter - Maximum
0 in
Discharge Diameter
1 in

Details

Item
Booster Pump
Booster Pump Type
Multi-Stage Booster Pump
HP - Pumps
2 hp
Voltage - Pumps
120/240V AC
Phase - Pumps
1
Number of Stages - Pumps
11
Max. Pressure - Pumps
150 psi
Housing Material - Pumps
Stainless Steel
Motor Enclosure - Pumps
Open Dripproof
Phase
Single
GPM @ 60 PSI
29.3
Housing Material
304 SS Shell, Cast Iron Suction And Discharge
Motor Type
Capacitor-Start
Impeller Material
Noryl
Inlet
1" FNPT
Motor RPM
3,450 RPM
Wetted Materials
Noryl,304 SS,CI,316 SS,Carbon,Ceramic,Buna N,BZ
Pump Mounting Position
Horizontal or Vertical with Inlet Down
GPM @ 40 PSI
31.3
Agency Compliance
CSA, CUS, UL Listed
Duty
Continuous
Outlet
1" FNPT
Max. Pressure
150 psi
HP
2
Max. Liquid Temp.
140 Degrees F
GPM @ 100 PSI
23.8
Impeller Type
Closed
Voltage
115/230
GPM @ 120 PSI
19.8
Bearing Type
Ball
Motor Enclosure
Open Dripproof (ODP)
Frame
NEMA 56J
Max. Case Pressure
300 psi
Stages
11
GPM @ 80 PSI
26.8
GPM @ 140 PSI
13
Amps
25/12.5 A
Includes
Kit, Vertical Motor Cover
Seal Material
Buna-N/Carbon/Ceramic/Stainless Steel
Suction Lift
0 ft
Hz
60
Motor Ambient Temp. Rating
65 Degrees C
Standards
CSAus Certified
Application
Boosting
Priming
Manual
For Use With Potable Systems
No
Case Pressure (Maximum)
300 psi
Flow Rate @ 80 psi
27.1 gpm
Intake Type
NPT
Flow Rate @ 90 psi
25 gpm
Minimum Flow Rate
1.5 gpm
Flow Rate @ 15 psi
33 gpm
Duty Cycle
Continuous
Shut Off Pressure (Maximum)
147 psi
Impeller Design
Closed
Flow Rate @ 20 psi
34 gpm
Series
PB
Flow Rate @ 100 psi
24.2 gpm
Discharge Type
NPT
Maximum Flow Rate
41.5 gpm
Flow Rate @ 60 psi
29.5 gpm
Flow Rate @ 30 psi
32.5 gpm
Frequency
60 Hz
Flow Rate @ 70 psi
27.5 gpm
Mounting Orientation
Horizontal
Flow Rate @ 120 psi
20.3 gpm
Motor Frame Designation
56J
Maximum Media Temperature
140 Degrees F
Flow Rate @ 140 psi
13 gpm
Flow Rate @ 40 psi
31.5 gpm
Suction Lift (Maximum)
0 ft
Horsepower
2 hp
Maximum RPM
3,450 RPM
Pump Housing Material
Cast Iron
Nameplate Voltage
115/230V AC
Compatible with Media Type
Clear Water Only
Motor Ambient Temperature (Minimum)
65 Degrees F
Number of Stages
11
Pressure Boost (Maximum)
216 psi
Motor Ambient Temperature (Maximum)
149 Degrees F
Pumping Application
Booster Service, General Purpose, Jockey Pump, Pressure Cleaning, Reverse Osmosis, Spray or Mist Systems, Water Circulation
Thermal Overload Protection
Yes
Wetted Material
304 Stainless Steel, 316 Stainless Steel, Bronze, Buna-N, Cast Iron, Ceramic, Noryl
Minimum Media Temperature
34 Degrees F
Flow Rate @ 50 psi
31 gpm
Media Temperature - Minimum
34 Degrees F
Pressure Boost - Maximum
216 psi
Discharge Gender
Female
NSF Certifications for Food and Drinking Water
NSF 372
Inlet Gender
Female
Flow Rate - Maximum
42 gpm
Feet of Head - Maximum
337 ft
Suction Lift - Maximum
0 ft
Full Load Current
25/12.5 A
Installation
Floor Standing
Electrical Connection Type
Hardwired
Case Pressure - Maximum
300 psi
Motor Ambient Temperature - Maximum
149 Degrees F
Power Source
Corded Electric
Best Efficiency Flow
27 gpm
Motor Enclosure Design
Open Drip Proof
Thermal Protection
Auto
Best Efficiency Head
194 ft
Motor Ambient Temperature - Minimum
32 Degrees F
Inlet Standard
NPT
Motor Design
Capacitor-Start
Pump Technology
Centrifugal
Revolutions Per Minute - Maximum
3,450 RPM
Discharge Standard
NPT
Media Temperature - Maximum
140 Degrees F
Shut Off Pressure - Maximum
147 psi
For Media Type
Clear Water
Flow Rate - Minimum
2 gpm
Pump Casing Material
Cast Iron

Description

Booster Pump, Phase Single, Pump Housing Material Cast Iron, Motor Enclosure Open Dripproof, Horsepower 2 hp, Nameplate Voltage 115/230V AC, Flow Rate @ 20 psi 34 gpm, Flow Rate @ 30 psi 32.5 gpm, Flow Rate @ 40 psi 31.5 gpm, Flow Rate @ 50 psi 31 gpm, Flow Rate @ 60 psi 29.5 gpm, Flow Rate @ 70 psi 27.5 gpm, Flow Rate @ 80 psi 27.1 gpm, Flow Rate @ 90 psi 25 gpm, Flow Rate @ 100 psi 24.2 gpm, Flow Rate @ 120 psi 20.3 gpm, Shut Off Pressure (Maximum) 147 psi, Compatible Intake Pipe Size 1 in

Restrictions

Ratings & Reviews

3 Reasons You Can Count On Us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.