- Item
- Drywall Temperature Calibrator
- Includes
- 6 ft Main Power Cord, 9190 Insert D, 9930 Interface-It Calibration Software and Users Guide, Getting Started Manual, Insert Removal Tool, Product CD, Report of Calibration and Calibration Label, USB Cable, Well Insulator Cap
- Display
- LCD
- Standards
- IEC 61010-1, Installation Category II, Pollution degree 2, IEC 61326-1: Basic
- Interface
- RS-232, USB Cable
- Loop Supply Voltage
- 24V DC
- Accuracy
- +/-0.2 Degrees C Full Range
- RTD Type
- 4 Wire, 3 Wire, 2 Wire
- Application
- Blood Banks, Cold Rooms, Freeze Dryers, Laboratory Refrigerators, Medical Freezers, Sterilizers (Autoclaves)
- RTD Temperature Range
- -139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C)
- Thermocouple Type
- C, E, J, K, L, M, N, R, S, T, U
- Max. Loop Current
- 4 to 20mA
- Agency Compliance
- EU Directives, CSA, Australian EMC Requirements
- Thermocouple Temperature Range
- -139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C)
- Calibration Certificate
- yes
- Power Source
- Plug-In
- Display Temperature Accuracy
- +/-0.2 Degrees C
- Calibrator Type
- Field Metrology Well
- Thermocouple Temperature Range C
- -95 Degrees to 140 Degrees C
- Typical Cooling Time
- 60 min (140 Degrees to 23 Degrees C), 80 min (23 Degrees to -90 Degrees C), 90 min (23 Degrees to -95 Degrees C)
- Current mA Characteristics
- 0.02% + 0.002 mA Accuracy/4 to 22 mA, 4 to 24 mA Range
- RTD Temperature Range C
- -95 Degrees to 140 Degrees C
- RTD Temperature Range F
- -139 Degrees to 284 Degrees F
- Stability
- +/-0.015 Degrees C
- Reference Input Temperature Characteristics
- +/-0.010 Degrees C at -95 Degrees C, +/-0.013 Degrees C at -25 Degrees C, +/-0.015 Degrees C at 0 Degrees C, +/-0.020 Degrees C at 50 Degrees C, +/-0.025 Degrees C at 140 Degrees C
- Stabilization Time
- 10 min
- Typical Heating Time
- 40 min (-95 Degrees to 140 Degrees C)
- Power Source Details
- 100 to 115V, 200 to 230V
- Sensor Type
- RTD, Thermocouple
- For Thermocouple Type
- Type C, Type E, Type J, Type K, Type L, Type M, Type N, Type R, Type S, Type T, Type U
- Brand and Series
- Fluke 9190A
- Calibrator Weight
- 35 lb
- For RTD Type
- 2-Wire, 3-Wire, 4-Wire, Ni-120, PT-100 (385), PT-100 (3926), PT-100 (JIS)
- Reference Junction Temperature Characteristics
- +/- 0.35 Degrees C Accuracy at Ambient Temperature of 13 Degrees to 33 Degrees C
- Reference Input Resistance Characteristics
- +/--0.0025 ohm Accuracy (0 to 42 ohm), +/-60 ppm of Reading Accuracy (42 to 400 ohm)
- Probe Connection Types
- (1) 4-Terminal RTD Input, (1) Miniature Connectors (ASTM E1684)
- Thermocouple Temperature Range F
- -139 Degrees to 284 Degrees F
- Resistance Sensing Current Characteristics
- 0.02% at 0.002 mA; Cal 4-22 mA, Spec 4-24 mA
- Thermocouple mV Characteristics
- 0.025% + 0.01 mV at -10 to 75 mV
- With Process Connections
- Yes
- Display Resolution
- 0.01 Degrees F
- Thermocouple Temperature Accuracy Characteristics
Type C: +/-1.00 Degrees C at 140 Degrees C, Type E: +/-0.60 Degrees C at 140 Degrees C, Type J: +/-0.70 Degrees C at 140 Degrees C, Type K: +/-0.75 Degrees C at 140 Degrees C, Type L: +/-0.65 Degrees C at 140 Degrees C, Type M: +/-0.65 Degrees C at 140 Degrees C, Type N: +/-0.75 Degrees C at 140 Degrees C, Type R: +/-1.60 Degrees C at 140 Degrees C, Type S: +/-1.60 Degrees C at 140 Degrees C, Type T: +/-0.60 Degrees C at 140 Degrees C, Type U: +/-0.70 Degrees C at 140 Degrees C
- Calibrator Accuracy
- +/-0.2 Degrees C
- Typical Uniformity
- +/-0.05 Degrees C
- Temperature Range
- -139 Degrees to 284 Degrees F/-95 Degrees to 140 Degrees C
- 4-Wire Device Resistance Characteristics
- Range: 0 to 400 ohms/Accuracy: +/-0.0025 ohms (0 to 42 ohms), +/-60 ppm of Reading (42 to 400 ohms)
- Number of Set Points
- Variable
- Single Well/Dual Well
- Single Well
- Set Point Style
- Adjustable
- Temperature Accuracy
- +/-0.2 Degrees C
- Temperature Set Points
- -95 Degrees C, 140 Degrees C
- Process Connections Included
- Reference PRT, RTD, Thermocouple, Transmitter
- Insert Type Included
- D
- Interchangeable Insert
- Yes
- RTD Temperature Fahrenheit - Maximum
- 284 Degrees F
- Number of Insert Holes
- 6
- RTD Temperature Celsius - Maximum
- 140 Degrees C
- Thermocouple Temperature Celsius - Maximum
- 140 Degrees C
- Includes Process Connections
- Yes
- Calibration Certificate Type
- Accredited
- Thermocouple Temperature Fahrenheit - Minimum
- -139 Degrees F
- Series
- 9190A
- Number of Inserts Included
- 1
- Thermocouple Temperature Celsius - Minimum
- -95 Degrees C
- RTD Temperature Celsius - Minimum
- -95 Degrees C
- RTD Temperature Fahrenheit - Minimum
- -139 Degrees F
- Sensor Technology
- RTD, Thermocouple
- Thermocouple Temperature Fahrenheit - Maximum
- 284 Degrees F
- Voltage
- 100 to 115V, 200 to 230V
- Power Source - TS Only
- Plug-In