Shop FLUKE

Handheld Digital Oscilloscope, 190 Series III ScopeMeter, 2 Channel, 200 MHz, True RMS

  • Mfr # FLUKE-190-202-III-S

  • Zoro # G802016121


product price: 
$
6,679.99
/ea
Free Shipping & Returns
Zoro's best price: not eligible for any other offers or promotions

Key Features

Includes
(4) TRM50 Cable Terminators, (4) VPS410-II Probes, AC Power Adapter, Carrying Case, DWA-131 Wi-Fi Dongle, Hand Strap, Hanging Strap, Power Cord, USB Cable
Features
10,000 Points per Trace Waveform Capture (Scope Mode), 4 Independently Floating Isolated Inputs Up to 1000V, 999 Count DMM (2-ch Models: Insulated 5,000 Counts DMM Built-In), Automatic Capture and Replay of 100 Screens, Connect-and-View(TM) Triggering, Frequency Spectrum Analysis Using FFT-Analysis, ScopeRecord(TM) Roll Mode, TrendPlot(TM) Paperless Recorder Mode with Deep Memory, Up to 5 GS/s High-Speed Sampling
Display
Full Color LCD
Channels
2
Triggering Mode
Auto
See all product information
Unlock 30-day payment terms
Unlock 30-day payment terms
Business customers can apply for Net 30—no fees, no interest, fast approval. Terms apply.
Create Account
Get 10% off your order
Get 10% off your order
Sign up for our email list and receive your promo code via email.

Specifications

Details

MFR #
FLUKE-190-202-III-S
Zoro #
G802016121
UPC #
195112021859
Country of Origin
Romania
Item
Digital Oscilloscope
Includes
(4) TRM50 Cable Terminators, (4) VPS410-II Probes, AC Power Adapter, Carrying Case, DWA-131 Wi-Fi Dongle, Hand Strap, Hanging Strap, Power Cord, USB Cable
Features
10,000 Points per Trace Waveform Capture (Scope Mode), 4 Independently Floating Isolated Inputs Up to 1000V, 999 Count DMM (2-ch Models: Insulated 5,000 Counts DMM Built-In), Automatic Capture and Replay of 100 Screens, Connect-and-View(TM) Triggering, Frequency Spectrum Analysis Using FFT-Analysis, ScopeRecord(TM) Roll Mode, TrendPlot(TM) Paperless Recorder Mode with Deep Memory, Up to 5 GS/s High-Speed Sampling
Display
Full Color LCD
Channels
2
Triggering Mode
Auto
Input Sensitivity
With 10:1 Probe, 20 mV to 1000 V/div_x000B; With 100:1 Probe, 200 mV to 10 kV/div _x000B; Direct (1:1), 2 mV to 100 V/div
Safety Rating
CAT III 1000V/CAT IV 600V
Calibration Certificate
Yes
Persistence
Off, Short, Medium, Long, Infinite and Envelope Mode
Waveform / Measurement Stored
Two Multiple Input ScopeRecord Waveforms Can Be Saved Internally for Later Recall And Analysis
Glitch Capture
Yes
Battery Type
Rechargeable Li-Ion
Real Time Clock
Yes, Provides Date and Time Stamp Information for ScopeRecord, for 100 Screen Replay Sequences and for TrendPlot Recordings
True RMS
Yes
Battery Life
Up to 3 hr
Power Source
Battery
Sampling Rate
125 MS/s
FFT Analysis
Yes
Max./Min. Sweep Speed
2 nsec/div to 4 sec/div
Interface
USB
Number of Channels
2
Time Base - Minimum
2 nsec/div
Battery Run Time
3.5 hr
DC Voltage Measurement - Maximum
1,100 V DC
Channel Source Isolation
Fully Isolated
Basic DC Voltage Accuracy
+/-(0.50% +6 Counts)
Standards
EN 61010-1, IEC 61010-2-030: CAT IV 600V/CAT III 1000V
Basic AC Voltage Accuracy
+/-(1% +10 Counts)
Includes Batteries
Batteries Included
IP Rating
IP51
Calibration Certificate Type
Not Certified
Body Style
Handheld
Input Sensitivity - Maximum
100 V/div
Input Sensitivity - Minimum
100 V/div
CAT Safety Rating
CAT III 1000V, CAT IV 600V
AC Voltage Measurement Resolution
100 mV
AC Magnitude Calculation
True RMS
Digital Display Screen Type
LCD
Time Base - Maximum
4 sec/div
AC Voltage Measurement - Minimum
500 mV AC
AC Voltage Measurement - Maximum
1,100 V AC
Battery Chemistry
Lithium Ion
DC Voltage Measurement - Minimum
500 mV DC
Power Source - TS Only
Battery
Power Source - old
Battery

Description

FLUKE-190-202-III-S is a handheld digital oscilloscope with 2 channels, 200 MHz bandwidth, and a full-color LCD display. It is designed for electrical signal measurement and analysis, with fully isolated channels, True RMS voltage measurement, FFT analysis, glitch capture, and built-in recording functions for reviewing waveform activity over time. The unit operates on a rechargeable lithium-ion battery and supports USB connectivity for data transfer.

Key Features of the FLUKE-190-202-III-S Digital Oscilloscope:

  • Bandwidth and channels: 200 MHz bandwidth with 2 channels for viewing and comparing multiple signals.
  • Voltage measurement range: Measures AC and DC voltage from 500 mV up to 1,100 V, with True RMS AC magnitude calculation.
  • Accuracy: Basic AC voltage accuracy of ±(1% +10 counts) and basic DC voltage accuracy of ±(0.50% +6 counts).
  • Sampling and recording: 125 MS/s sampling rate, up to 5 GS/s high-speed sampling, 10,000 points per trace waveform capture, and 30,000 data points per channel memory depth.
  • Time base: Sweep speed from 2 nsec/div to 4 sec/div for capturing both fast and slower signal changes.
  • Display: Full-color LCD with a 5.2 in x 3.5 in screen area.
  • Analysis functions: Includes FFT analysis, glitch capture, ScopeRecordTM, TrendPlotTM, persistence modes, and automatic capture and replay of 100 screens.
  • Isolation and safety rating: Fully isolated channel source design with CAT III 1000V and CAT IV 600V ratings.
  • Power and interface: Rechargeable Li-Ion battery powered, with up to 3.5 hr battery run time and USB interface.
  • Included accessories: Supplied with VPS410-II probes, TRM50 cable terminators, AC power adapter, USB cable, Wi-Fi dongle, carrying case, power cord, hand strap, and hanging strap.

Ratings & reviews