- Item
- Digital Pressure Sensor
- Range
- 0 to 5800 psi
- Power Required
- 18 to 30V DC
- Process Connection
- 1/4 in NPT
- Electrical Connection
- 4-Pin M12 Male Connector
- Display
- Display unit 3 x LED, green (bar, psi, MPa) switching status 2 x LED, yellow measured values alphanumeric display, red/green 4-digit
- IP Rating
- IP65, IP67
- Burst Pressure
- 24,650 psi
- Output Current
- 150mA, 200mA @ 60 Degrees C, 250mA @ 40 Degrees C
- Housing Material
- Stainless Steel
- Temp. Range
- -13 Degrees to 176 Degrees F
- Wetted Materials
- Ceramic, Fluorocarbon
- Contact Form
- 1NO/1NC
- Off Set Point
- 20 to 5780 psi
- Compatible With
- Air and Liquids
- On Set Point
- 40 to 5800 psi
- Circuit Type
- PNP/NPN
- Application
- for industrial applications
- Series
- PN
- Product Type
- Digital Pressure Sensor
- Materials
- 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
- Reverse polarity protection
- yes
- Min. pressure cycles
- 100 million
- EMC
- DIN EN 61000-6-2 DIN EN 61000-6-3
- Protection
- IP 65; IP 67
- Response time [ms]
- < 3
- IO-Link functions (acyclical)
- application specific tag
- Set point SP
- 4...400 bar 40...5800 psi 0.4...40 MPa, 3...400 bar 49...5802 psi 0.3...40 MPa
- Media
- liquids and gases
- Min. difference between SP and rP
- 2 bar 30 psi 0.2 MPa, 2 bar 10 psi 0.2 MPa
- Type of pressure
- relative pressure
- Required master port type
- A; (when pin 2 not connected: B)
- Measuring range
- 0...400 bar 0...5800 psi 0...40 MPa
- Profiles
- Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis, Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
- IO-Link resolution pressure [bar]
- 1, 0.2
- Hysteresis deviation [% of the span]
- <± 0,25
- Special feature
- Gold-plated contacts
- Parameter setting options
- hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit
- Connection
- Connector: 1 x M12; coding: A; Contacts: gold-plated
- Min. bursting pressure
- 1700 bar 24650 psi 170 MPa
- Power-on delay time [s]
- 0.3
- IO-Link resolution pressure [MPa]
- 0.1, 0.02
- Characteristics deviation [% of the span]
- <± 0,25 (BFSL) / <± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
- Current consumption [mA]
- < 35
- IO-Link revision
- 1.1
- Min. process cycle time [ms]
- 3, 2.3
- Pressure rating
- 800 bar 11580 psi 80 Mpa
- Output signal
- switching signal; IO-Link; (configurable)
- Shock resistance
- DIN EN 60068-2-27 50 g (11 ms)
- Integrated watchdog
- yes
- SIO mode
- yes
- Switch point accuracy [% of the span]
- <± 0,5
- Long-term stability [% of the span]
- <± 0,05; (per 6 months)
- Vibration resistance
- DIN EN 60068-2-6 20 g (10...2000 Hz)
- MTTF [years]
- 214
- In steps of
- 1 bar 1 psi 0.1 MPa, 2 bar 20 psi 0.2 MPa
- Number of digital outputs
- 2
- Output function
- normally open / normally closed; (parameterisable)
- Temperature coefficient span [% of the span / 10 K]
- 0,2; (-25...80°C)
- Operating voltage [V]
- 18...30 DC; (to SELV/PELV)
- Max. voltage drop switching output DC [V]
- 2.5
- Short-circuit protection
- yes
- Permanent current rating of switching output DC [mA]
- 150; (200 (...60°C) 250 (...40°C))
- Medium temperature [°C]
- -25...80
- Temperature coefficient zero point [% of the span / 10 K]
- 0,2; (-25...80°C)
- Ambient temperature [°C]
- -25...80
- IO-Link process data (cyclical)
- function bit length pressure 16 device status 4 binary switching information 2, function bit length pressure 14 binary switching information 2
- Storage temperature [°C]
- -40...100
- Repeatability [% of the span]
- <± 0,1; (with temperature fluctuations < 10 K)
- SDCI standard
- IEC 61131-9
- Pressure Equipment Directive
- Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
- MAWP (for applications according to CRN)
- 800 bar 11580 psi 80 MPa
- Restrictor element integrated
- no (can be retrofitted)
- Number of inputs and outputs
- Number of digital outputs: 2
- Electrical design
- PNP/NPN
- Protection class
- III
- Overload protection
- yes
- Transmission type
- COM2 (38,4 kBaud)
- Switching frequency DC [Hz]
- < 170
- Total number of outputs
- 2
- Min. insulation resistance [MΩ]
- 100; (500 V DC)
- Delay time programmable dS, dr [s]
- 0...50
- UL approval
- UL Approval no. J003
- Communication interface
- IO-Link
- Materials (wetted parts)
- 1.4542 (17-4 PH / 630)
- Reset point rP
- 1...398 bar 20...5773 psi 0.1...39.8 MPa, 2...398 bar 20...5780 psi 0.2...39.8 MPa
- Type of short-circuit protection
- pulsed
- Measuring element
- metallic thin film cell
- Operating Temperature - Maximum
- 176 Degrees F
- Pressure Connection Type
- 1/4" FNPT
- Pressure - Maximum
- 5,800 psi
- Electrical Design Output
- PNP/NPN
- Compatible Media
- Gas, Liquid
- Reset Point - Minimum
- 20 psi
- Operating Temperature - Minimum
- -13 Degrees F
- Output Current Rating
- 0.15 A, 0.2 A @ 140 Degrees F, 0.25 A @ 104 Degrees F
- Set Point - Minimum
- 40 psi
- Set Point - Maximum
- 5,800 psi
- Reset Point - Maximum
- 5,780 psi
- Pressure - Minimum
- 0 psi
- Voltage Rating - Maximum
- 30 V DC
- Switching Signal Output
- PNP/NPN
- Current Rating
- 150 mA, 200 mA, 250 mA
- Switch Structure
- SPST