Item
Electromechanical Timer
Enclosure Type
N/A - Mechanism only
Description/Special Features
for Replacement or Specialized Applications, Time Switches
Applications
Timing/Scheduling ON/OFF; Indoor Lighting Control
Minimum On Off Time
1 hour
Solutions
Machinery & Pumps; Panel Integrators
Power Consumption Max W
3 W
Heater Control Output
10 A, 250 VAC MAX, 60 Hz
Pilot Duty Load Ratings Ranges
1000 VA, 120-277 VAC, 60 Hz
Electronic Ballast Load Ratings Ranges
16 A, 120-277 VAC
Resistive Load Ratings
40 A, 480 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz; 40 A, 347 VAC, 60 Hz
Input Voltage Ranges
208-277 VAC, 60 Hz
Maximum On Off Operations
12
Electronic Ballast Load Ratings
16 A, 120 VAC; 16 A, 208 VAC; 16 A, 240 VAC; 16 A, 277 VAC
Resistive Load Ratings Ranges
40 A, 120-480 VAC, 60 Hz
Pilot Duty Load Ratings
1000 VA, 120 VAC, 60 Hz; 1000 VA, 208 VAC, 60 Hz; 1000 VA, 240 VAC, 60 Hz; 1000 VA, 277 VAC, 60 Hz
UL Cerfication File Number
UL917
Inductive Load Ratings
40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz
Skipper Wheel Operation Mode
Not Included
Motor Load Ratings
2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
Application Compatibilities
LED; HID
Packaging Applications
Indoor/Outdoor Lighting; Signs; Filters; Electric Fences; Fans; Conveyors; Pool Heaters; Blowers; Pumps; Other Electrical loads
Number Of Trippers Included
1 ON/1 OFF
Tungsten Load Ratings
40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz
Has Manual Override CVL
Yes
Tungsten Load Ratings Ranges
40 A, 120-277 VAC, 60 Hz
Market
Commercial; Industrial
Inductive Load Ratings Ranges
40 A, 120-277 VAC, 60 Hz
Operating Temperature Min
-40°C
Operating Temperature Max
130°C
Motor Load Ratings Ranges
2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
Input Voltage Range(s)
208-277 VAC, 60 Hz
Electronic Ballast
16 A, 120 VAC, 16 A, 208 VAC, 16 A, 240 VAC, 16 A, 277 VAC
Inductive
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz
Pilot Duty (NO)
1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz, 1000 VA, 277 VAC, 60 Hz
Features
Teeter-Type Terminals
Operating Temperature Max (°F)
130
Tungsten (NO)
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz
Resistive
40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz, 40 A, 347 VAC, 60 Hz, 40 A, 480 VAC, 60 Hz
Operating Temperature Min (°F)
-40
Maximum ON/OFF Operations
12
Skipper Wheel
Not Included
Minimum ON/OFF Times
1 hour
Maximum Power Consumption (W)
3 W
Tungsten Range(s)
40 A, 120-277 VAC, 60 Hz
Operating Temperature Min (°F)
-40
Operating Temperature Max (°F)
130
Compatible with Series
T100
Product Type
Mechanical Time Switch
Compatible Product Type
Enclosure
Compatible with Brand
Intermatic
Includes
(2) Trippers, 208-277V AC DPST Timer Switch
Indoor/Outdoor Usage
Indoor/Outdoor