- MFR #
- T101R
- Zoro #
- G2275323
- UPC #
- 078275000056
- Country of Origin
- Mexico
- Item
- Electromechanical Timer
- Voltage
- 120V AC
- Operation Mode
- 25 hour
- Amps
- 40 A
- Time Minimum Setting
- 1 hr.
- Enclosure Type
- Steel
- Indoor/Outdoor Usage
- Indoor/Outdoor
- Min. Time Setting
- 1 hr
- Body Material
- Steel
- Contact Form
- SPST
- Max. Time Setting
- 23 hr
- Max. On/Off Cycles
- 12
- Extra Trippers
- 2E054
- Description/Special Features
- 3R Enclosures in Steel or Noncorrosive Plastic, Has Adjustable Time Setting, Manual On/Off Override does not Alter Program, Snap-out Timing Mechanism, Up to 12 On/Off Settings Per Day
- Time Setting Range
- 1 hr. to 23 hr.
- Day Skipper
- No
- Nominal Max. Time Setting
- 24 hr
- Contact HP @ 120V
- 2 hp
- Contact HP @ 240V
- 5 hp
- NEMA Rating
- 3R
- Type
- 24-Hour
- Number of Poles
- 1
- Number of Trippers Included
- 2
- Mount
- Hole Wall
- Finish
- Metal Enclosure has Gray Enamel
- Standards
- cCSAus, cULus
- Product Type
- Timer
- Electronic Ballast Load Ratings Ranges
- 16 A, 120 VAC
- Application Compatibilities
- LED; HID
- Packaging Applications
- Indoor/Outdoor Lighting; Signs; Filters; Electric Fences; Fans; Conveyors; Pool Heaters; Blowers; Pumps
- Has Manual Override CVL
- Yes
- Operating Temperature Min
- -40°C
- Power Consumption Max W
- 3 W
- Minimum On Off Time
- 1 hour
- UL Certification
- cULus
- Market
- Commercial; Industrial
- Inductive Load Ratings
- 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz
- Solutions
- Machinery & Pumps; Panel Integrators
- Motor Load Ratings
- 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
- Skipper Wheel Operation Mode
- Not Included
- Maximum On Off Operations
- 12
- Electronic Ballast Load Ratings
- 16 A, 120 VAC
- Operating Temperature Max
- 130°C
- Input Voltage Ranges
- 120 VAC, 60 Hz
- Tungsten Load Ratings Ranges
- 40 A, 120-240 VAC, 60 Hz
- Pilot Duty Load Ratings
- 1000 VA, 120-240 VAC, 60 Hz
- CSA Certification
- cCSAus
- Inductive Load Ratings Ranges
- 40 A, 120-240 VAC, 60 Hz
- Tungsten Load Ratings
- 40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz
- UL Cerfication File Number
- UL917
- Wiring Option
- Terminals
- Switch Type
- SPST
- Resistive Load Ratings Ranges
- 40 A, 120-240 VAC, 60 Hz
- Number Of Circuits
- 1
- Applications
- Timing/Scheduling ON/OFF; Indoor Lighting Control; Outdoor Lighting Control
- Resistive Load Ratings
- 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz
- Pilot Duty Load Ratings Ranges
- 1000 VA, 120-240 VAC, 60 Hz
- Maximum ON/OFF Operations
- 12
- Operating Temperature Max (°F)
- 130
- Has Manual Override
- Yes
- Tungsten Range(s)
- 40 A, 120-240 VAC, 60 Hz
- Operating Temperature Min (°F)
- -40
- Inductive
- 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz
- Input Voltage Range(s)
- 120 VAC, 60 Hz
- Features
- Manual Override
- Skipper Wheel
- Not Included
- Electronic Ballast
- 16 A, 120 VAC
- Tungsten (NO)
- 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz
- Resistive
- 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz
- Pilot Duty (NO)
- 1000 VA, 120-240 VAC, 60 Hz
- Motor Load Ratings Ranges
- 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
- Minimum ON/OFF Times
- 1 hour
- Maximum Power Consumption (W)
- 3 W
- Operating Temperature Max (°F)
- 130
- Operating Temperature Min (°F)
- -40
- Operating Temperature - Maximum
- 130 Degrees F
- Mounting Style
- Surface
- Compatible Lighting
- HID, LED
- AC Voltage Rating
- 120V AC
- Number of Trippers - Maximum
- 2
- Series
- T100
- Operating Temperature - Minimum
- -40 Degrees F
- On/Off Cycles - Maximum
- 12
- Body Color
- Grey
- Current Rating - Maximum
- 40 A
- Horsepower @ 240V - Maximum
- 5 hp
- Time Setting - Maximum
- 24 hr
- NEMA Enclosure Rating
- 3R
- Application
- Lighting
- Time Setting - Minimum
- 1 hr
- Horsepower @ 120V - Maximum
- 2 hp
- Time Maximum Setting
- 24 hr