- Item
- Electronic Timer
- Operation Mode
- 366 Days
- Number of Channels
- 1
- Time Minimum Setting
- 2 sec
- Indoor/Outdoor Usage
- Outdoor
- Voltage
- 120 to 277V AC
- Body Material
- Metal
- Contact Form
- SPDT
- Amps
- 30 A
- HP @ 120V
- NC: 1/4, NO: 1
- HP @ 240V
- NC: 1/2, NO: 2
- Events Available - Electronic Timer
- 4,000
- Available Actions - Electronic Timer
- Cycle, On/Off, Pulse
- Operating Temp.
- -40 Degrees to 120 Degrees F
- Pulse Duration
- 1 sec to 24 hr
- Backup Time
- 100 hr
- Max. Time Setting
- 365 day
- Description/Special Features
- Ethernet Module, Copy Programming To Other Time Switches For Backup Purposes Via USB
- Number of Poles
- 1
- Backup Device
- Capacitor
- Event Allocation - Electronic Timer
- 1 Cycle Action = 1 Event, 1 On/Off Action = 1 Event, 1 Pulse Action = 1 Event
- NEMA Rating
- 3R
- Mounting
- Snap-In
- Standards
- cCSAus, cULus, California Title 20
- Max. On/Off Cycles
- 4000
- Enclosure
- Metal
- Number of Pulse Events
- 4000
- Min. Time Setting
- 1 sec
- Color
- Gray
- Max. Ballast Amps
- 8 A, 120-277 VAC, 50/60 Hz
- Hz - Electrical
- 50-60 Hz
- Switch Type
- SPDT
- Enclosure Type
- Outdoor type 3R metal
- Features
- Advanced Scheduling Including Relative Events, Ethernet Communication Port
- Max. Wattage
- 16 W
- Adjustment Type
- Automatic
- Application
- Lighting, Machinery, Pump Controls
- Voltage Type
- Auto Voltage
- Series
- ET90000
- Maximum Pulse Time
- 23 hours, 59 minutes
- Pilot Duty (NC)
- 275 VA, 120 VAC, 50 Hz, 275 VA, 120 VAC, 60 Hz, 275 VA, 208 VAC, 50 Hz, 275 VA, 208 VAC, 60 Hz, 275 VA, 240 VAC, 50 Hz, 275 VA, 240 VAC, 60 Hz
- General Purpose (NC)
- 10 A, 120 VAC, 50 Hz, 10 A, 120 VAC, 60 Hz, 10 A, 12 VAC, 50 Hz, 10 A, 12 VAC, 60 Hz, 10 A, 18 VAC, 50 Hz, 10 A, 18 VAC, 60 Hz, 10 A, 208 VAC, 50 Hz, 10 A, 208 VAC, 60 Hz, 10 A, 240 VAC, 50 Hz, 10 A, 240 VAC, 60 Hz, 10 A, 24 VAC, 50 Hz, 10 A, 24 VAC, 60 Hz
- Magnetic Ballast (NO)
- 20 A, 120 VAC, 50 Hz, 20 A, 120 VAC, 60 Hz, 20 A, 208 VAC, 50 Hz, 20 A, 208 VAC, 60 Hz, 20 A, 240 VAC, 50 Hz, 20 A, 240 VAC, 60 Hz, 20 A, 277 VAC, 50 Hz, 20 A, 277 VAC, 60 Hz
- Pilot Duty (NO) Range(s)
- 470 VA, 120-240 VAC, 50/60 Hz
- Data Transfer Options
- Ethernet Optional/USB
- Resistive (NO) Range(s)
- 20 A, 28 VDC; 30 A, 12-240 VAC, 50/60 Hz
- General Purpose (NO) Range(s)
- 30 A, 12-240 VAC, 50/60 Hz
- Minimum Pulse Time
- 1 sec
- Maximum ON/OFF Times
- 365 days
- Input Voltage Range(s)
- 120-277 VAC, 50/60 Hz
- Applications
- Indoor Lighting Control
Machinery & Pump Controls
Outdoor Lighting Control
Timing/Scheduling ON/OFF
- Operation Features
- Astronomic, Holiday
- Tungsten (NO) Load Ratings
- 5 A, 110 VAC, 50 Hz, 5 A, 110 VAC, 60 Hz, 5 A, 115 VAC, 50 Hz, 5 A, 115 VAC, 60 Hz, 5 A, 12 VAC, 50 Hz, 5 A, 12 VAC, 60 Hz, 5 A, 120 VAC, 50 Hz, 5 A, 120 VAC, 60 Hz, 5 A, 24 VAC, 50 Hz, 5 A, 24 VAC, 60 Hz, 5 A, 50 VAC, 50 Hz, 5 A, 50 VAC, 60 Hz
- Operating Temperature Min (°F)
- -40
- Motor Load Ratings NO Ranges
- 1 HP, 120 VAC, 50/60 Hz; 2 HP, 240 VAC, 50/60 Hz
- Magnetic Ballast (NC) Range(s)
- 3 A, 120-277 VAC, 50/60 Hz
- Tungsten (NO) Range(s)
- 5 A, 12-120 VAC, 50/60 Hz
- Voltage Selection Type
- Auto Voltage
- Wiring Option
- Terminals
- Daylight Savings Adjustment
- Automatic
- Minimum ON/OFF Times
- 1 sec
- Operating Temperature Max (°F)
- 104
- Resistive (NC) Range(s)
- 10 A, 28 VDC; 10 A, 12-240 VAC, 50/60 Hz
- Electronic Ballast Load Ratings NO Ranges
- 8 A, 120-277 VAC, 50/60 Hz
- Pilot Duty (NC) Range(s)
- 275 VA, 120-240 VAC, 50/60 Hz
- Backup Type
- Supercapacitor
- Motor Load Ratings NC Ranges
- 1/4 HP, 120 VAC, 50/60 Hz; 1/2 HP, 240 VAC, 50/60 Hz
- Maximum ON/OFF Operations
- 2000
- Electronic Series
- ET90000 Series
- General Purpose (NO)
- 30 A, 120 VAC, 50 Hz, 30 A, 120 VAC, 60 Hz, 30 A, 12 VAC, 50 Hz, 30 A, 12 VAC, 60 Hz, 30 A, 18 VAC, 50 Hz, 30 A, 18 VAC, 60 Hz, 30 A, 208 VAC, 50 Hz, 30 A, 208 VAC, 60 Hz, 30 A, 240 VAC, 50 Hz, 30 A, 240 VAC, 60 Hz, 30 A, 24 VAC, 50 Hz, 30 A, 24 VAC, 60 Hz
- Magnetic Ballast (NC)
- 3 A, 120 VAC, 50 Hz, 3 A, 120 VAC, 60 Hz, 3 A, 208 VAC, 50 Hz, 3 A, 208 VAC, 60 Hz, 3 A, 240 VAC, 50 Hz, 3 A, 240 VAC, 60 Hz, 3 A, 277 VAC, 50 Hz, 3 A, 277 VAC, 60 Hz
- Magnetic Ballast (NO) Range(s)
- 20 A, 120-277 VAC, 50/60 Hz
- UL Certification
- CULUS
- General Purpose (NC) Range(s)
- 10 A, 12-240 VAC, 50/60 Hz
- Pilot Duty (NO)
- 470 VA, 120 VAC, 50 Hz, 470 VA, 120 VAC, 60 Hz, 470 VA, 208 VAC, 50 Hz, 470 VA, 208 VAC, 60 Hz, 470 VA, 240 VAC, 50 Hz, 470 VA, 240 VAC, 60 Hz
- Number Of Circuits
- 1
- Backup Restoration Time
- 30 Minutes
- Electronic Ballast (NO)
- 8 A, 120 VAC, 50 Hz, 8 A, 120 VAC, 60 Hz, 8 A, 208 VAC, 50 Hz, 8 A, 208 VAC, 60 Hz, 8 A, 240 VAC, 50 Hz, 8 A, 240 VAC, 60 Hz, 8 A, 277 VAC, 50 Hz, 8 A, 277 VAC, 60 Hz
- On Off Operations
- 2000
- Maximum Power Consumption (W)
- 16 W
- Backup Protection Time
- 100 Hour
- Operating Temperature Min (°F)
- -40
- Operating Temperature Max (°F)
- 104
- Pulse Duration - Minimum
- 1 sec
- Events Available
- 2,000
- Time Setting - Maximum
- 365 day
- Electrical Installation Type
- Screw Terminal
- AC Voltage Rating
- 120-277V AC
- Operating Temperature - Maximum
- 104 Degrees F
- Timer Functions
- On/Off
- Horsepower @ 120V - Maximum
- 1 hp
- Mounting Style
- Surface
- Time Setting - Minimum
- 1 sec
- Operating Temperature - Minimum
- -40 Degrees F
- NEMA Enclosure Rating
- 3R
- Current Rating - Maximum
- 30 A
- Body Color
- Grey
- Horsepower @ 240V - Maximum
- 2 hp
- Pulse Duration - Maximum
- 24 hr
- Astronomic Functionality
- Yes
- Time Maximum Setting
- 366 day