- MFR #
- XACS411
- Zoro #
- G0862097
- UPC #
- 785901447238
- Country of Origin
- Czechia
- Item
- Pendant Station Contact
- Type of Operator
- spring return
- Standards
- CSA C22.2 No 14, EN 60947-5-1, IEC 60947-5-1
- Terminal Connection
- screw clamp terminals, 1 x 2.5 mm² with or without cable end || screw clamp terminals, 2 x 1.5 mm² with or without cable end
- Terminal Identifier
- (13-14)NO, (11-12)NC
- Product Compatibility
- ZA2B... head, XACA
- Range of Product
- Harmony XAC
- Horizontal Fixing Centres
- 40 mm
- Rated Operational Power In Va
- 140 VA AC-15 1000000 cycles 60 cyc/mn 24 V 50/60 Hz 0.5 inductive, 385 VA AC-15 1000000 cycles 60 cyc/mn 48 V 50/60 Hz 0.5 inductive, 455 VA AC-15 1000000 cycles 60 cyc/mn 230 V 50/60 Hz 0.5 inductive, 525 VA AC-15 1000000 cycles 60 cyc/mn 127 V 50/60 Hz 0.5 inductive
- Contact Block Type
- single
- Electrical Circuit Type
- control circuit
- Component Name
- XACS
- Contacts Type And Composition
- 1 NO
- Product or Component Type
- contact block
- [Ui] Rated Insulation Voltage
- 500 V 3)IEC 60947-1
- Shock Resistance
- 100 gn IEC 60068-2-27
- Connections - Terminals
- screw clamp terminals, 1 x 2.5 mm² with or without cable end, screw clamp terminals, 2 x 1.5 mm² with or without cable end
- Mechanical Interlocking
- without mechanical interlock
- Mechanical Durability
- 1000000 cycles
- Terminals Description Iso N°1
- (13-14)NO
- Ambient Air Temperature For Storage
- -40-70°C
- Vibration Resistance
- 15 gn 10-500 Hz)IEC 60068-2-6
- Contact Code Designation
- A300 AC-15, Ue = 240 V, Ie = 3 A IEC 60947-5-1 appendix A, Q300 DC-13, Ue = 250 V, Ie = 0.27 A IEC 60947-5-1 appendix A
- Vertical Fixing Centres
- 30 mm
- Maximum Resistance Across Terminals
- 25 MOhm
- Contact Operation
- slow-break
- Rated Operational Power In W
- 42 W DC-13 1000000 cycles 60 cyc/mn 120 V 0.5 inductive IEC 60947-5-1 appendix C, 45 W DC-13 1000000 cycles 60 cyc/mn 48 V 0.5 inductive IEC 60947-5-1 appendix C, 60 W DC-13 1000000 cycles 60 cyc/mn 24 V 0.5 inductive IEC 60947-5-1 appendix C
- Mounting of Block
- front mounting
- [Ithe] Conventional Enclosed Thermal Current
- 10A
- Short-Circuit Protection
- 10 A fuse protection cartridge gG
- Ambient Air Temperature For Operation
- -25-70°C
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60947-1
- Type Of Operator
- spring return
- Mounting Of Block
- front mounting
- Product Or Component Type
- contact block