- Item
- Control Station
- Material
- polycarbonate
- Cable Entry
- 2 knock-outs for cable entry 14-14 mm || 2 knock-outs for Pg 13 cable gland and ISO M20 12-12 mm
- Standards
- JIS C8201-5-1 || EN/IEC 60947-1 || EN/IEC 60947-5-4 || EN/IEC 60947-5-5 || CSA C22.2 No 14 || UL 508 || EN/IEC 60947-5-1 || JIS C8201-1
- Ambient Air Temperature For Storage
- -40-70°C
- Shape Of Screw Head
- cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm
- Contacts Material
- silver alloy (Ag/Ni)
- [Ith] Conventional Free Air Thermal Current
- 10 A EN/IEC 60947-5-1
- Product Or Component Type
- complete control station
- Ik Degree Of Protection
- IK03 EN 50102
- Resistance To High Pressure Washer
- 7000000 Pa 55°C 0.1 m
- Device Short Name
- XALD
- Colour Of Cover
- dark grey RAL 7016)
- Operating Force
- 3.8 N NO changing electrical state
- Electrical Durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
- Operators Description
- white ''up arrow'' 1 NO - black ''down arrow'' 1 NO
- Connections - Terminals
- screw clamp terminals, <= 2 x 1.5 mm² with cable end EN/IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end EN/IEC 60947-1
- Ip Degree Of Protection
- IP66 IEC 60529 || IP67 || IP69 || IP69K
- Colour Of Marking
- black marking when white caps || white marking when green, red or black caps
- Positive Opening
- without
- Control Station Application
- two functions
- Colour Of Base Of Enclosure
- light grey RAL 7035)
- Operator Profile
- 2 flush push-buttons
- Product Certifications
- UL Listed || CSA
- [Ie] Rated Operational Current
- 6 A 120 V, AC-15, A600 EN/IEC 60947-5-1 || 3 A 240 V, AC-15, A600 EN/IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1
- Shock Resistance
- 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
- Control Station Composition
- 1 flush push-button, white 1 NO, black up arrow || 1 flush push-button, black 1 NO, white down arrow
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV EN/IEC 60947-1
- [Ui] Rated Insulation Voltage
- 600 V 3)EN/IEC 60947-1
- Vibration Resistance
- 5 gn 12-500 Hz)IEC 60068-2-6
- Operating Travel
- 2.6 mm NO changing electrical state) || 4.3 mm total travel)
- Protective Treatment
- TH
- Marking Location
- marking on push-button
- Electrical Shock Protection Class
- class II IEC 60536
- Short-Circuit Protection
- 10 A cartridge fuse gG EN/IEC 60947-5-1
- Ambient Air Temperature For Operation
- -40-70°C
- Product Destination
- for XB5 Ø 22 mm control and signalling units
- Mechanical Durability
- 5000000 cycles
- Electrical Reliability
- λ < 10exp(-6) 5 V 1 mA EN/IEC 60947-5-4 || λ < 10exp(-8) 17 V 5 mA EN/IEC 60947-5-4
- Nema Degree Of Protection
- NEMA 13 || NEMA 4X
- Tightening Torque
- 0.8-1.2 N.m EN/IEC 60947-1
- Contact Operation
- slow-break
- Enclosure Base Cover
- Light Gray RAL 7035)
- Rated Operational Current
- 6 A 120 V, AC-15, A600 EN/IEC 60947-5-1; 3 A 240 V, AC-15, A600 EN/IEC 60947-5-1; 1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1; 0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1; 0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1; 0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1
- Cover Color
- Dark Gray RAL 7016)
- Marking Color
- Black marking when white caps; White marking when green, red or black caps
- Product Type
- Control Station