- MFR #
- VLS3P032D1
- Zoro #
- G0858695
- UPC #
- -
- Country of Origin
- Korea, Republic of
- Item
- Disconnect Switch
- Contact Form
- 3P
- Current Rating
- 32 A
- Phase
- Three
- HP
- 29.5 HP @ 690 V
- Voltage
- 690 V
- Handle Color
- Gray
- Standards
- UL 508, IEC 60947-3, CSA C22.2 No 14
- Number of Poles
- 3
- Amps
- 25 A, 32 A
- Includes
- Rotary Handle
- Duty
- Intermittent
- IP Rating
- 20
- Use
- Body Switch Disconnector
- Color
- Gray
- Rated Conditional Short-Circuit Current
- 50 kA 400 V 32 A gG
- Mechanical Robustness
- vibrations 2...100 Hz Fc 0.7 g) IEC 60068-2-6 || shocks 11 ms Ea 15 gn) IEC 60068-2-27
- Range
- TeSys
- Fire Resistance
- 960°C IEC 60695-2-11
- Mounting Support
- door
- Device Short Name
- VLS3P
- Breaking Capacity
- 48 A 690 V AC-21A) || 96 A 690 V AC-22A) || 256 A 690 V AC-23A)
- Product Certifications
- cULus || GL
- Connections - Terminals
- power circuit screw clamp terminals 10-10 mm² solid || power circuit screw clamp terminals 16-16 mm² flexible - without cable end
- Poles Description
- 3P
- Making Capacity
- 320 A 690 V AC-23A || 48 A 690 V AC-21A || 96 A 690 V AC-22A
- Electrical Durability
- 100000 cycles AC-21A
- Ip Degree Of Protection
- IP20 conforming to IEC 60529
- Product Name
- TeSys VARIO LS
- Performance Level
- high performance
- Product Or Component Type
- switch body
- Network Frequency
- 50/60 Hz
- Intermittent Duty Class
- class 120 - 60 %
- Ambient Air Temperature For Operation
- -25-55°C
- Mechanical Durability
- 100000 cycles
- Tightening Torque
- power circuit 1.8-2 N.m screw clamp terminals
- Rated Operational Power In W
- 15 kW 400 V AC-23A) || 18.5 kW 500 V AC-23A) || 22 kW 690 V AC-23A)
- Network Type
- AC
- Contacts Type And Composition
- 3 NO
- UL Rated Operational Voltage
- 600 V AC 50/60 Hz UL 508
- Rated Operational Current
- 32 A Ue: 600 V UL 508; 32 A AC-21A Ue: 400 V; 32 A AC-21A Ue: 500 V; 32 A AC-21A Ue: 690 V; 32 A AC-22A Ue: 400 V; 32 A AC-22A Ue: 500 V; 32 A AC-22A Ue: 690 V; 32 A AC-23A Ue: 400 V; 25 A AC-23A Ue: 500 V; 25 A AC-23A Ue: 690 V
- Rated Operational Voltage
- 690 V AC 50/60 Hz
- Short Circuit Current Rating
- Fuse RK5 45 A maximum: 5 kA at 600 V AC
- UL Maxium Horsepower Ratings
- 10 hp 200/208 V AC; 10 hp 240 V AC; 20 hp 480 V AC; 20 hp 600 V AC; 2 hp 120 V AC; 5 hp 240 V AC
- Conventional Free Air Thermal Current
- 32 A (at 131°F (55°C))
- Iec Rated Operational Power in W
- 15 kW 400 V AC-23A; 18.5 kW 500 V AC-23A; 22 kW 690 V AC-23A)
- IEC Terminal Connection
- Power circuit screw clamp terminals 0.02 in² (10 mm²) solid; Power circuit screw clamp terminals 0.02 in² (16 mm²) flexible - without cable end