Key Features

Power Required
24V DC
Number of Inputs
6
Number of Outputs
4
For Use With
SR3 Logic Relays
Features
Simple Programming
See all product information
Unlock 30-day payment terms
Unlock 30-day payment terms
Business customers can apply for Net 30—no fees, no interest, fast approval. Terms apply.
Create Account
Get 10% off your order
Get 10% off your order
Sign up for our email list and receive your promo code via email.

Specifications

Details

MFR #
SR3XT101BD
Zoro #
G0263724
UPC #
785901693789
Country of Origin
Indonesia
Item
Discrete Input/Output Module
Power Required
24V DC
Number of Inputs
6
Number of Outputs
4
For Use With
SR3 Logic Relays
Features
Simple Programming
Product Type
Discrete Input/Output Module
Standards
EN/IEC 61000-4-4 level 3 || EN/IEC 61000-4-2 level 3 || EN/IEC 61000-4-3 || EN/IEC 61000-4-12 || EN/IEC 61000-4-11 || EN/IEC 60068-2-6 Fc || EN/IEC 60068-2-27 Ea || EN/IEC 61000-4-6 level 3 || EN/IEC 61000-4-5
Output Type
(4) Relay
Electrical Durability
AC-15 500000 cycles 230 V, 0.9 A relay output EN/IEC 60947-5-1 || AC-12 500000 cycles 230 V, 1.5 A relay output EN/IEC 60947-5-1 || DC-13 500000 cycles 24 V, 0.6 A relay output EN/IEC 60947-5-1 || DC-12 500000 cycles 24 V, 1.5 A relay output EN/IEC 60947-5-1
Ambient Air Temperature For Storage
-40-70°C
Current State 1 Guaranteed
>= 1.2 mA IB to IG used as discrete input circuit) || >= 2.2 mA I1 to IA and IH to IR discrete input circuit)
Overvoltage Category
III EN/IEC 60664-1
Tightening Torque
0.5 N.m
Reverse Polarity Protection
with
Output Thermal Current
8 A for all 4 outputs relay output
Input Compatibility
3-wire proximity sensors PNP discrete input
Product Certifications
GL || C-tick || UL || GOST || CSA
Disturbance Radiated/Conducted
class B EN 55022-11 group 1
Switching Capacity In Ma
>= 10 mA 12 V relay output)
Voltage State 0 Guaranteed
<= 5 V I1 to IA and IH to IR discrete input circuit || <= 5 V IB to IG used as discrete input circuit
Contacts Type And Composition
NO relay output
Pollution Degree
2 EN/IEC 61131-2
Backup Time
10 years 25°C
Clock Drift
12 min/year 0-55°C
Input Impedance
12 kOhm IB to IG used as discrete input circuit || 7.4 kOhm I1 to IA and IH to IR discrete input circuit
Mechanical Durability
10000000 cycles relay output
Discrete Input Type
resistive
[Uimp] Rated Impulse Withstand Voltage
4 kV EN/IEC 60947-1 and EN/IEC 60664-1
Voltage State 1 Guaranteed
>= 15 V I1 to IA and IH to IR discrete input circuit || >= 15 V IB to IG used as discrete input circuit
Output Voltage Limits
24 to 250 V AC relay output) || 5 to 30 V DC relay output)
Discrete Input Number
6 EN/IEC 61131-2 type 1
Counting Frequency
1 kHz discrete input
Relative Humidity
95-95 % without condensation or dripping water
Environmental Characteristic
EMC directive EN/IEC 61000-6-2 || EMC directive EN/IEC 61000-6-3 || EMC directive EN/IEC 61000-6-4 || EMC directive EN/IEC 61131-2 zone B || low voltage directive EN/IEC 61131-2
Discrete Input Current
4 mA
Ambient Air Temperature For Operation
-20-40°C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55°C IEC 60068-2-1 and IEC 60068-2-2
Ip Degree Of Protection
IP20 IEC 60529 terminal block) || IP40 IEC 60529 front panel)
Discrete Input Voltage
24 V DC
[Us] Rated Supply Voltage
24 V DC
Operating Altitude
6561.68 ft (2000 m)
Supply Voltage Limits
19.2-30 V
Number Or Control Scheme Lines
120-120 ladder
Current State 0 Guaranteed
<= 0.5 mA IB to IG used as discrete input circuit) || <= 0.75 mA I1 to IA and IH to IR discrete input circuit)
Maximum Altitude Transport
3048 m
Response Time
10 ms from state 0 to state 1)relay output || 5 ms from state 1 to state 0)relay output
Operating Rate In Hz
0.1 Hz at Ie)relay output || 10 Hz no load)relay output
Connections - Terminals
screw terminals, 1 x 0.25 to 1 x 2.5 mm² AWG 24 to AWG 14) flexible with cable end || screw terminals, 2 x 0.25 to 2 x 0.75 mm² AWG 24 to AWG 18) flexible with cable end || screw terminals, 1 x 0.2 to 1 x 2.5 mm² AWG 25 to AWG 14) semi-solid || screw terminals, 1 x 0.2 to 1 x 2.5 mm² AWG 25 to AWG 14) solid || screw terminals, 2 x 0.2 to 2 x 1.5 mm² AWG 24 to AWG 16) solid
Product Or Component Type
discrete I/O extension module
Cycle Time
6-90 ms
Checks
Program memory on each power up
Input Type
(6) Discrete
Input Circuit Current - Maximum
4 mA
Output Circuit Current - Maximum
8 A
Wire Connection Type
Screw Clamp
Current Rating
4 mA
Mounting Style
DIN Rail
Compatible Product Type
Smart Relays
Input Circuit Voltage - Maximum
24 V DC
Output Circuit Voltage - Maximum
30 V DC, 250 V AC
Compatible with Brand
Schneider
Output Circuit Voltage - Minimum
5 V DC, 24 V AC
Compatible with Series
SR3, Zelio Logic
Compatible Series
SR3, Zelio Logic

Dimensions

Overall Depth
2.34 in
Overall Height
3.5 in
Overall Width
2.8 in
Fits Chest Size
Simple Programming

Description

Discrete Input/Output Module, Number of Inputs 6, For Use With SR3 Logic Relays, Number of Outputs 4, Power Required 24V DC, Features Simple Programming, Product Type Extension Module, Current Rating 4 mA, Mounting Style DIN Rail, Wire Connection Type Screw Clamp

Ratings & reviews

3 reasons you can count on us

  • Supplies for every job.

    13 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    4.5 million products ship in 1 day.

  • Stretch your budget further.

    Everyday low prices on the brands you love.