- Item - Relay
- IEC Style Control Relay
- Coil Volts
- 24V DC
- AC Contact Rating - Relay
- 10A @ 120/240/480/600V
- DC Contact Rating - Relay
- 2.00A @ 125/250/600V
- Number of Pins - Relay
- 12
- Contact Form - Relay
- (2) SPST-NC, (3) SPST-NO
- Mounting - Relay
- DIN Rail, Surface
- Response Time
- 15 to 25 msec (Coil De-Energisation and NC Closing), 16 to 24 msec (Coil De-Energisation and NO Opening), 47 to 63 msec (Coil Energisation and NC Opening), 53 to 72 msec (Coil Energisation and NO Closing)
- Item
- IEC Control Relay
- Contact Material
- Silver Nickel
- Power Consumption - Relay
- 3.0 VA
- Contact Amp Rating (Resistive)
- 10A
- Features
- 3.03 in H x 1.77 in W x 3.66 in D
- Coil Rating
- 3VA Inrush, 3VA Sealed
- Standards
- CSA Certified, EAC, IEC, RoHS Compliant, UKCA, UL Listed
- Contact Form
- 3NO/2NC
- Mounting
- Din Rail/Panel
- Range
- TeSys || TeSys Deca
- Time Constant
- 28 ms
- [Ue] Rated Operational Voltage
- <= 690 V AC 25...400 Hz
- Connections - Terminals
screw clamp terminals 1 1-4 mm²flexible without cable end || screw clamp terminals 2 1-4 mm²flexible without cable end || screw clamp terminals 1 1-4 mm²flexible with cable end || screw clamp terminals 2 1-2.5 mm²flexible with cable end || screw clamp terminals 1 1-4 mm²solid without cable end || screw clamp terminals 2 1-4 mm²solid without cable end
- Associated Fuse Rating
- 10 A gG IEC 60947-5-1
- Protective Treatment
- TH IEC 60068
- Minimum Switching Voltage
- 17 V
- Mounting Support
- rail || plate
- Product Certifications
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- [Ith] Conventional Free Air Thermal Current
- 10 A 60°C
- Hold-In Power Consumption In W
- 5.4-5.4 W 20°C
- Operating Time
- 53...72 ms coil energisation and NO closing || 16...24 ms coil de-energisation and NO opening || 47...63 ms coil energisation and NC opening || 15...25 ms coil de-energisation and NC closing
- Non-Overlap Time
- 1.5 ms on energisation between NC and NO contact || 1.5 ms on de-energisation between NC and NO contact
- Product Name
- TeSys CAD
- Control Circuit Voltage Limits
- 0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
- Mechanical Robustness
- shocks control relay open10 Gn for 11 ms IEC 60068-2-27 || shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 || vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6 || vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6
- Operating Altitude
- 0...9842.52 ft (0...3000 m)
- Minimum Switching Current
- 5 mA
- Ip Degree Of Protection
- IP2X front face VDE 0106
- Pole Contact Composition
- 3 NO + 2 NC
- Ambient Air Temperature For Storage
- -60-80°C
- Insulation Resistance
- > 10 MOhm
- Control Circuit Type
- DC standard
- Ambient Air Temperature For Operation
- -40-60°C || 60-70°C with derating
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60947
- Inrush Power In W
- 5.4-5.4 W 20°C)
- [Uc] Control Circuit Voltage
- 24 V DC
- [Ui] Rated Insulation Voltage
- 600 V UL || 600 V CSA || 690 V IEC 60947-5-1
- Tightening Torque
- 1.2 N.m screw clamp terminals Philips No 2 || 1.2 N.m screw clamp terminals flat Ø 6 mm || 1.2 N.m screw clamp terminals pozidriv No 2
- [Icw] Rated Short-Time Withstand Current
- 100 A - 1 s || 120 A - 500 ms || 140 A - 100 ms
- Utilisation Category
- DC-13 || AC-15 || AC-14
- Device Short Name
- CAD
- Maximum Operating Rate
- 180 cyc/mn
- Product Or Component Type
- control relay
- Mechanical Durability
- 30 Mcycles
- Contactor Application
- control circuit
- Irms Rated Making Capacity
- 140 A AC IEC 60947-5-1 || 250 A DC IEC 60947-5-1
- Mounting Style
- DIN Rail and Surface
- Input Voltage
- 24V DC
- Contact Rating (DC)
- 2 A @ 125/250/600V
- Coil Voltage
- 24V DC
- IP Rating
- IP2X
- Power Consumption
- 5.4 W
- Number of Pins
- 12
- Relay Style
- IEC
- Current Rating
- 10 A
- Weight
- 1.28 lb
- Compatible with Series
- TeSys D Control Relays
- Maximum Operating Temperature
- 140 Degrees F
- Electrical Connection
- Screw Clamp
- Minimum Operating Temperature
- -40 Degrees F
- Contact Rating (AC)
- 10 A @ 120/240/480/600V
- Conventional Free Air Thermal Current
- 10 A (at 140°F (60°C))
- Rated Short Time Withstand Current
- 100 A - 1 s; 120 A - 500 ms; 140 A - 100 ms
- Rated Insulation Voltage
- 600 V UL; 600 V CSA; 690 V IEC 60947-5-1
- Rated Operational Voltage
- Less than or Equal to 690 V AC 25 to 400 Hz