- Item
- IEC Magnetic Contactor
- Auxiliary Contact Form
- 1NC/1NO
- Coil Voltage
- 120V AC
- Number of Poles
- 3
- Full Load Amps-Inductive
- 25 A
- Full Load Amps-Resistive
- 40 A
- Reversing Capability
- Reversing
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 2
- Standards
- BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
- Frame / Series / Class / Code
- TeSys
- Reversing
- Yes
- Enclosure NEMA Rating
- No Enclosure
- Series
- TeSys Deca
- HP @ 3 Phase - 575V
- 20 hp
- Switching Voltage
- 17 V (Signalling Circuit)
- IP Rating
- IP20
- Net Weight
- 0.787 kg
- Includes Protective Cover
- Yes
- Max. Operating Watts
- 5.5 kW (at 220 to 230V AC 50 Hz), 11 kW (at 380 to 400V AC 50 Hz), 11 kW (at 415 to 440V AC 50 Hz), 15 kW (at 500V AC 50 Hz), 15 kW (at 660 to 690V AC 50 Hz)
- Impulse Withstand Voltage
- 6 kV
- Shock Resistance
- 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
- Application
- Motor Control, Resistive Load
- Rated Making Capacity
- 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)
- Rated Breaking Capacity
- 450 A @ 440V
- Mechanical Durability
- 15 Mcycles
- Electrical Durability
- 1.65 Mcycles (25 A, AC-3, Less than 440 V); 1.4 Mcycles (40 A, AC-1, Less than 440 V)
- Vibration Resistance
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Inrush VA
- 70 VA
- Tightening Torque
- 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
- Fire Rating
- UL 94 V1
- Environmental Attributes
- Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
- Fuse Amps
- 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit)
- Overvoltage Category
- CAT III
- Non-Overlap Time
- 1.5 ms
- Impedance
- 2 mOhm
- Switching Current
- 5 mA (Signalling Circuit)
- Operating Speed
- 3600 cycles per hr
- Features
- Without Built-In Suppressor Module; Preassembled with Reversing Power Busbar
- Control Circuit Voltage Limits
- Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
- Watts Loss
- 2 to 3W
- Signalling Circuit Frequency
- 25 to 400 Hz
- Rated Insulation Volts
- 600/690V
- Hold VA
- 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
- Operating Time
- 12 to 22 ms (Closing), 4 to 19 ms (Opening)
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Rated Short-Time Withstand Current
- 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
- Minimum Operating Temperature
- -40 Degrees F
- Mechanical Operating Durability
- 15,000,000
- Horsepower @ Single Phase - 240V AC
- 3 hp
- Mounting Style
- DIN Rail, Plate
- Electrical Operating Durability
- 1,400,000, 1,650,000
- Maximum Operating Temperature
- 140 Degrees F
- Contactor Style
- IEC
- Horsepower @ Three Phase - 240V AC
- 7 1/2 hp
- Horsepower @ Single Phase - 120V AC
- 2 hp
- Full Load Current - Resistive
- 40 A
- Maximum Voltage Rating
- 690V AC
- Embedded Surge Suppressor
- No
- Includes Auxiliary Contacts
- Yes
- Frequency
- 50/60 Hz
- Horsepower @ Three Phase - 208V AC
- 5 hp
- Resistance Properties
- Fire Resistant, Insulation Resistant
- Number of Normally Open Main Contacts
- 3
- Full Load Current - Inductive
- 25 A
- Horsepower @ Three Phase - 480V AC
- 15 hp
- NEMA Enclosure Rating
- No Enclosure
- Horsepower @ Three Phase - 600V AC
- 20 hp
- Climatic Withstand
- IACS E10; IEC 60947-1 Annex Q category D
- Mechanical Robustness
- Vibrations contactor open2 Gn, 5 to 300 Hz; Vibrations contactor closed4 Gn, 5 to 300 Hz; Shocks contactor closed15 Gn for 11 ms; Shocks contactor open8 Gn for 11 ms
- Pollution Degree
- 3
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Heat Dissipation
- 2 to 3 W 50/60 Hz
- Control Circuit Voltage
- 120 V AC 50/60 Hz
- Power Dissipation Per Pole
- 1.25 W AC-3; 3.2 W AC-1; 1.25 W AC-3e
- Contactor Application
- Motor control; Resistive load
- Ambient Air Temperature For Storage
- -76 to 176°F (-60 to 80°C)
- Product Name
- TeSys Deca; TeSys Deca
- Protective Treatment
- TH IEC 60068-2-30
- Device Presentation
- Preassembled with reversing power busbar
- Rated Operational Voltage
- Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
- Fire Resistance
- 1562°F (850°C) IEC 60695-2-1
- Interlocking Type
- Mechanical
- Conventional Free Air Thermal Current
- 10 A (at 140°F (60°C)) for signalling circuit; 40 A (at 140°F (60°C)) for power circuit
- Auxiliary Contacts Type
- Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
- Utilisation Category
- AC-1; AC-3; AC-3e
- Control Circuit Type
- AC 50/60 Hz
- Front Cover
- With
- Operating Altitude
- 0 to 9842.52 ft (0 to 3000 m)
- Ambient Air Temperature For Operation
- -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
- Maximum Operating Rate
- 3600 cyc/h 140°F (60°C)
- Inrush Power in VA
- 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
- Rated Operational Current
- 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit
- Pole Contact Composition
- 3 NO