Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Full Load Amps-Inductive
115 A
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
CSA C22.2 No 14, CSA C22.2 No 60947-4-1, EN 60947-4-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, IEC 60947-4-1, JIS C8201-4-1, UL 60335-2-40:Annex JJ, UL 60947-4-1
HP @ 3 Phase - 575V
100 hp
Thermal Amperage
200 A (at 60°C Power Circuit)
Rated Voltage
1000V AC, 300V DC
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Operating Time
6 to 20 ms (Opening), 20 to 50 ms (Closing)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Operating Speed
2400 cycles per hr
Electrical Connection
Screw Clamp Terminals
Application
Motor Control, Resistive Load
Signalling Circuit Frequency
25 to 400 Hz
Overvoltage Category
CAT III
Switching Voltage
17 V (Signalling Circuit)
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz)
Electrical Durability
0.8 Mcycles (200 A, AC-1, Less than 440 V); 0.95 Mcycles (115 A, AC-3, Less than 440 V); 0.95 Mcycles (115 A, AC-3e, Less than 440 V)
Impulse Withstand Voltage
8 kV
Fuse Amps
250 A (Type 1 Power Circuit), 200 A (Type 2 Power Circuit), 10 A (Signalling Circuit)
Rated Breaking Capacity
1100 A @ 440V
Shock Resistance
15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Rated Short-Time Withstand Current
250 A (at 40°C for 10 min Power Circuit), 550 A (at 40°C for 1 min Power Circuit), 950 A (at 40°C for 10 s Power Circuit), 1100 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Rated Making Capacity
1260 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Rated Insulation Volts
600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Features
Built-In Bi-Directional Peak Limiting Diode Suppressor
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Mechanical Durability
8 Mcycles
Includes Protective Cover
Yes
Max. Operating Watts
30 kW (at 220 to 230V AC 50/60 Hz AC-3), 55 kW (at 380 to 400V AC 50/60 Hz AC-3), 59 kW 415 to (at 440V AC 50/60 Hz AC-3), 75 kW (at 500V AC 50/60 Hz AC-3), 80 kW (at 660 to 690V AC 50/60 Hz AC-3), 65 kW (at 1000V AC 50/60 Hz AC-3), 18.5 kW (at 400V AC 50/60 Hz AC-4), 30 kW (at 220 to 230V AC 50/60 Hz AC-3e), 55 kW (at 380 to 400V AC 50/60 Hz AC-3e), 59 kW 415 to (at 440V AC 50/60 Hz AC-3e), 75 kW (at 500V AC 50/60 Hz AC-3e), 80 kW (at 660 to 690V AC 50/60 Hz AC-3e), 65 kW (at 1000V AC 50/60 Hz AC-3e)
Switching Current
5 mA (Signalling Circuit)
Tightening Torque
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Horsepower @ Three Phase - 600V AC
100 hp
Full Load Current - Inductive
115 A
Horsepower @ Three Phase - 480V AC
75 hp
Horsepower @ Three Phase - 240V AC
40 hp
Horsepower @ Three Phase - 208V AC
30 hp
Full Load Current - Resistive
200 A
Mounting Style
Plate, DIN Rail
Electrical Operating Durability
950,000
Resistance Properties
Fire Resistant, Insulation Resistant
Response Time
20 to 50 msec (Closing), 6 to 20 msec (Opening)
Maximum Operating Temperature
60 Degrees F
Number of Normally Open Main Contacts
3
Maximum Voltage Rating
1000V AC
Mechanical Operating Durability
8,000,000
Includes Auxiliary Contacts
Yes
Minimum Operating Temperature
-40 Degrees F