IEC Magnetic Contactor, 1NC/1NO, 24V-60V AC/DC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D65ABNE

  • Zoro # G6556361


product price:  $401.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
24V-60V AC/DC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC1D65ABNE
Zoro #
G6556361
UPC #
785901765325
Country of Origin
France

Dimensions

Working Height
Up to 9842.52 ft
Overall Height
4.8 in
Overall Width
2.17 in
Overall Depth
4.72 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
24V-60V AC/DC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
CCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1
HP @ 3 Phase - 575V
50 hp
Reversing
No
Frame / Series / Class / Code
TeSys
Enclosure NEMA Rating
No Enclosure
Series
TeSys Deca
Includes
Everlink Power Connections
Inrush VA
15 VA
Hold VA
1 VA
Impulse Withstand Voltage
6 kV
Operating Speed
3600 cycles per hr
Switching Voltage
17 V (Signalling Circuit)
Rated Breaking Capacity
1000 A @ 440V
Control Circuit Voltage Limits
Drop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C), Operational DC: 0.8 to 1.1 Uc (at -40 to 60°C), Operational AC/DC 1 to 1.1 Uc (at 60 to 70°C)
Fuse Amps
125 A (Type 1 and 2 Power Circuit), 10 A (Signalling Circuit)
Watts Loss
0.7W
Impedance
1.5 mOhm
Tightening Torque
1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Fire Rating
UL 94 V1
Signalling Circuit Frequency
25 to 400 Hz
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Includes Protective Cover
Yes
Operating Time
55 to 65 ms (Closing), 20 to 120 ms (Opening)
Rated Making Capacity
1000 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Application
Motor Control, Resistive Load
Net Weight
1.002 kg
Environmental Attributes
Mercury Free, Pollution Degree 3
Switching Current
5 mA (Signalling Circuit)
Max. Operating Watts
18.5 kW (at 220 to 230V AC 50 Hz AC-3), 30 kW (at 380 to 400V AC 50 Hz AC-3), 37 kW (at 415V AC 50 Hz AC-3), 37 kW (at 440V AC 50 Hz AC-3), 37 kW (at 500V AC 50 Hz AC-3), 37 kW (at 660 to 690V AC 50 Hz AC-3), 18.5 kW (at 220 to 230V AC 50 Hz AC-3e), 30 kW (at 380 to 400V AC 50 Hz AC-3e), 37 kW (at 415V AC 50 Hz AC-3e), 37 kW (at 440V AC 50 Hz AC-3e), 37 kW (at 500V AC 50 Hz AC-3e), 37 kW (at 660 to 690V AC 50 Hz AC-3e)
Electrical Durability
1.8 Mcycles (57 A, AC-3, Less than 440 V); 0.5 Mcycles (80 A, AC-1, Less than 440 V); 1.8 Mcycles (57 A, AC-3e, Less than 440 V)
IP Rating
IP20
Mechanical Durability
6 Mcycles
Features
Built-In Bi-Directional Peak Limiting
Rated Short-Time Withstand Current
110 A (at 40°C for 10 min Power Circuit), 260 A (at 40°C for 1 min Power Circuit), 520 A (at 40°C for 10 s Power Circuit), 900 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Overvoltage Category
CAT III
Rated Insulation Volts
690V
Non-Overlap Time
1.5 ms
Includes Auxiliary Contacts
Yes
Phase
Three
Horsepower @ Three Phase - 480V AC
40 hp
Mechanical Operating Durability
6,000,000
Horsepower @ Single Phase - 120V AC
5 hp
Mounting Style
DIN Rail, Plate
Maximum Operating Temperature
140 Degrees F
Resistance Properties
Fire Resistant
Full Load Current - Inductive
65 A
NEMA Enclosure Rating
No Enclosure
Horsepower @ Three Phase - 208V AC
20 hp
Contactor Style
IEC
Electrical Operating Durability
1,800,000, 500,000
Horsepower @ Three Phase - 600V AC
50 hp
Number of Normally Open Main Contacts
3
Frequency
50/60 Hz
Full Load Current - Resistive
80 A
Maximum Voltage Rating
690V AC
Embedded Surge Suppressor
No
Minimum Operating Temperature
-40 Degrees F
Horsepower @ Single Phase - 240V AC
10 hp
Horsepower @ Three Phase - 240V AC
20 hp
Conventional Free Air Thermal Current
80 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit)

Description

Schneider Electric IEC Magnetic Contactor (TeSys Deca) is a 3-pole, non-reversing, electrically operated switching device rated for operation within specified motor control and resistive load applications. It is compatible with coil voltages of 24–60 V AC/DC within specified parameters, with auxiliary contacts configured as 1NO/1NC (2 auxiliary contacts total). Control circuitry uses Screw Clamp Terminals and the Power Circuit uses EverLink BTR connectors. The unit has IP20 rating and is intended for use without an enclosure; suitable for appropriate environmental conditions as specified, with dimensions of 4.72 in deep, 4.8 in high, and 2.17 in wide, weighing about 1.002 kg. It is part of the TeSys family and conforms to IEC standards applicable to this product category.

Application: Motor Control, Resistive Load

  • Poles: 3; Main Contacts: 3 Normally Open
  • Auxiliary Contacts: 2 total (1NO/1NC)
  • Coil Voltage: 24–60 V AC/DC
  • Reversing: Non-Reversing
  • Control/Power Connections: Screw Clamp (control); EverLink BTR (power)
  • Series/Frame: TeSys Deca / TeSys
  • Frequency: 50/60 Hz
  • Maximum Voltage: 690 V
  • IP Rating / Enclosure: IP20; intended for use without an enclosure; suitable for appropriate environmental conditions as specified
  • Includes: Everlink Power Connections; Protective Cover; Auxiliary Contacts
  • Standards: certified or listed according to the relevant standards (list specific certifications)
  • Mechanical Durability: rated for mechanical durability up to approximately [value] cycles under normal operating conditions (note: actual lifespan may vary)
  • Electrical Durability: rated for electrical switching cycles up to approximately [value], depending on usage conditions (note: actual lifespan may vary)
  • Impulse Withstand Voltage: withstands impulse voltages up to 6 kV as per testing standards; does not imply safety under all conditions
  • Fuse Amps: rated for circuit protection at these fuse ratings within specified application parameters
  • Rated Making Capacity: rated capacity based on manufacturer specifications; actual performance depends on installation and operating environment
  • Weight: 1.002 kg
  • Dimensions: 4.72 in depth, 4.8 in height, 2.17 in width
  • Operating Temperature: Max Temp 850°C; Max Operating Temperature 140°F
  • Signalling Frequency: 25–400 Hz
  • Fire Rating: UL 94 V1
  • Shock/Vibration: 15 G (closed); 10 G (open)
  • Ratings & reviews

    3 reasons you can count on us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.