IEC Magnetic Contactor, 1NC/1NO, 600V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D09X7

  • Zoro # G0850538


product price:  $113.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
600V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC1D09X7
Zoro #
G0850538
UPC #
785901111207
Country of Origin
France

Dimensions

Working Height
Up to 9842.52 ft
Overall Height
77 mm
Overall Width
45 mm
Overall Depth
86 mm

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
600V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, CSA, RINA, CCC, UL, GL, BV, GOST, LROS, DNV, UKCA, THIEC 60068-2-30
Series
LC1D, TeSys Deca
HP @ 3 Phase - 575V
7 1/2 hp
Electrical Durability
0.6 Mcycles (25 A, AC-1, Less than 440 V); 2 Mcycles (9 A, AC-3, Less than 440 V); 2 Mcycles (9 A, AC-3e, Less than 440 V)
Impulse Withstand Voltage
6 kV
Operating Time
12 to 22 ms (Closing), 4 to 19 ms (Opening)
Signalling Circuit Frequency
25 to 400 Hz
Impedance
2.5 mOhm
Features
Without Built-In Suppressor Module
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Max. Operating Watts
2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW (at 380 to 400V AC 50/60 Hz AC-3), 4 kW 415 to (at 440V AC 50/60 Hz AC-3), 5.5 kW (at 500V AC 50/60 Hz AC-3), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 400V AC 50/60 Hz AC-3e), 4 kW 415 to (at 440V AC 50/60 Hz AC-3e), 5.5 kW (at 500V AC 50/60 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Operating Speed
3600 cycles per hr
Non-Overlap Time
1.5 ms
Includes Protective Cover
Yes
Rated Breaking Capacity
250 A @ 440V
Overvoltage Category
CAT III
Watts Loss
2 to 3W
Tightening Torque
1.7 Nm
Fuse Amps
10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Inrush VA
70 VA
Switching Voltage
17 V (Signalling Circuit)
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Mechanical Durability
15 Mcycles
Rated Short-Time Withstand Current
105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Switching Current
5 mA (Signalling Circuit)
Fire Rating
UL 94 V1
IP Rating
IP20
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Net Weight
0.32 kg
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Rated Insulation Volts
600/690V
Rated Making Capacity
250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Application
Motor Control, Resistive Load
Auxiliary Contacts Type
mechanically linked 1 NO + 1 NC IEC 60947-5-1, mirror contact 1 NC IEC 60947-4-1
Contactor Application
motor control, resistive load
Utilisation Category
AC-3, AC-4, AC-1, AC-3e
Mechanical Robustness
vibrations contactor open 2 Gn, 5...300 Hz) , vibrations contactor closed 4 Gn, 5...300 Hz) , shocks contactor open 10 Gn for 11 ms) , shocks contactor closed 15 Gn for 11 ms)
Protective Cover
with
Climatic Withstand
IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
[Icw] Rated Short-Time Withstand Current
105 A 40°C - 10 s for power circuit, 210 A 40°C - 1 s for power circuit, 30 A 40°C - 10 min for power circuit, 61 A 40°C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Control Circuit Type
AC 50/60 Hz
Protective Treatment
THIEC 60068-2-30
[Ui] Rated Insulation Voltage
power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, signalling circuit 600 V CSA, signalling circuit 600 V UL
Power Dissipation Per Pole
1.56 W AC-1, 0.2 W AC-3, 0.2 W AC-3e
Maximum Operating Rate
3600 cyc/h 60°C
Pole Contact Composition
3 NO
Operating Altitude
0...9842.52 ft (0...3000 m)
Heat Dissipation
2-3 W at 50/60 Hz
Fire Resistance
850°C IEC 60695-2-1
Horsepower @ Three Phase - 240V AC
2 hp
Horsepower @ Three Phase - 208V AC
2 hp
Horsepower @ Three Phase - 480V AC
5 hp
Horsepower @ Single Phase - 240V AC
1 hp
Full Load Current - Inductive
9:00 AM
Full Load Current - Resistive
25 A
Maximum Voltage Rating
690V AC, 300V DC
Conventional Free Air Thermal Current
25 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit)
Maximum Operating Temperature
140 Degrees F
Rated Operational Current
9 A (at <60°C) at <= 440 V AC AC-3 for power circuit, 25 A (at <60°C) at <= 440 V AC AC-1 for power circuit, 9 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Mounting Style
Plate, Rail
Rated Operational Voltage
power circuit <= 690 V AC 25...400 Hz, power circuit <= 300 V DC
Control Circuit Voltage
600 V AC 50/60 Hz
Inrush Power in VA
70-70 VA 60 Hz cos phi 0.75 (at 20°C), 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Ambient Air Temperature For Operation
-40-60°C, 60-70°C with derating

Description

The IEC Magnetic Contactor is a 3-pole, non-reversing electrical switching device with 1NC/1NO auxiliary contacts. It uses a 600 V AC coil and has a voltage rating of up to 690 V AC within specified operational parameters; it features screw clamp terminals for wiring. It is part of the TeSys Deca range and the LC1D series, intended for use in standard IEC magnetic contactor applications.

Auxiliary contacts: 2 total (mechanically linked 1 NO + 1 NC; 1NC/1NO form)

  • Poles and main contacts: 3 poles; 3 NO main contacts
  • Coil and control voltages: Coil 600 V AC; Control circuit 600 V AC
  • Power circuit voltage rating: Rated for operation within specified voltage ranges (25–400 Hz)
  • Electrical connections: Screw Clamp terminals
  • Mounting and mounting options: Mounting support on rail and plate; mounts on plate and rail
  • Enclosure and protection: IP20; Includes protective cover (With)
  • Weight: 0.32 kg
  • Ratings & reviews

    3 reasons you can count on us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.