Auxiliary Contact Form
1NO
Coil Voltage
24V DC
Number of Poles
3
Full Load Amps-Inductive
9 A
Full Load Amps-Resistive
9 A
See all product information
Unlock 30-day payment terms
Unlock 30-day payment terms
Business customers can apply for Net 30—no fees, no interest, fast approval. Terms apply.
Create Account
Get 10% off your order
Get 10% off your order
Sign up for our email list and receive your promo code via email.

Specifications

Details

MFR #
DPE09BL
Zoro #
G303481138
UPC #
-
Country of Origin
Indonesia
Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NO
Coil Voltage
24V DC
Number of Poles
3
Full Load Amps-Inductive
9 A
Full Load Amps-Resistive
9 A
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL Listed, UL 60947-4-1
Enclosure NEMA Rating
3R; 4
HP @ 3 Phase - 575V
7 1/2 hp
Frame / Series / Class / Code
TeSys
Reversing
No
Special Features
Overvoltage Category III; Minimum Switching Voltage 17 V Signalling Circuit; Insulation Resistance 10 MOhm Signalling Circuit
Features
Without Built-In Suppressor Module
Application
Motor Control, Resistive Load
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Control Circuit Voltage Limits
Drop-Out: 0.1 to 0.3 Uc (at 70°C); Operational: 0.8 to 1.25 Uc (at 60°C), 1 to 1.25 Uc (at 70°C)
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free, Pollution Degree 3
Rated Breaking Capacity
250 A @ 440V
Electrical Durability
0.6 Mcycles (20 A, AC-1, Less than 440 V); 1 Mcycles (9 A, AC-3, Less than 440 V)
Series
TeSys Easy
Rated Insulation Volts
600/690V
Fuse Amps
10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit)
Rated Making Capacity
250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Operating Time
65.45 to 88.55 ms (Closing), 20 to 30 ms (Opening)
Non-Overlap Time
1.5 ms
Switching Current
5 mA (Signalling Circuit)
IP Rating
IP20
Overvoltage Category
CAT III
Signalling Circuit Frequency
25 to 400 Hz
Net Weight
0.32 kg
Impedance
2.5 mOhm
Impulse Withstand Voltage
6 kV
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Operating Speed
3600 cycles per hr
Max. Operating Watts
2.2 kW (at 220 to 230V AC 50/60 Hz), 4 kW (at 380 to 400V AC 50/60 Hz), 4 kW (at 415 to 440V AC 50/60 Hz), 5.5 kW (at 500V AC 50/60 Hz), 5.5 kW (at 660 to 690V AC 50/60 Hz), 2.2 kW (at 400V AC 50/60 Hz)
Switching Voltage
17 V (Signalling Circuit)
Tightening Torque
1.7 Nm
Mechanical Durability
10 Mcycles
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Watts Loss
2 to 3W
Horsepower @ Single Phase - 240V AC
1 hp
Includes Auxiliary Contacts
Yes
Resistance Properties
Fire Resistant, Insulation Resistant
Horsepower @ Single Phase - 120V AC
1/3 hp
Horsepower @ Three Phase - 240V AC
2 hp
Horsepower @ Three Phase - 480V AC
3 hp
Horsepower @ Three Phase - 600V AC
7 1/2 hp
Contactor Style
IEC
Minimum Operating Temperature
-40 Degrees F
Embedded Surge Suppressor
No
Full Load Current - Resistive
9 A
Maximum Operating Temperature
140 Degrees F
Maximum Voltage Rating
690V AC
Frequency
50/60 Hz
Full Load Current - Inductive
9 A
Mechanical Operating Durability
10,000,000
Horsepower @ Three Phase - 208V AC
2 hp
Mounting Style
DIN Rail, Plate
Electrical Operating Durability
1,000,000, 600,000
Number of Normally Open Main Contacts
3
NEMA Enclosure Rating
No Enclosure
Conventional Free Air Thermal Current
10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)

Description

Schneider Electric IEC Magnetic Contactor, 3-pole, 24 V DC coil, non-reversing, 1 normally open auxiliary contact, mounted with screw clamp terminals. This IEC-style magnetic contactor is rated for operation within the specified voltage and current ranges in motor control and resistive load applications. It features a TeSys Easy frame and is suitable for installation in control panels with standard dimensions; complies with relevant standards.

Poles: 3; Main Contacts: 3 NO; Auxiliary Contacts: 1 NO; Coil Voltage: 24 V DC; Reversing: Non-Reversing

  • Frame: TeSys Easy; Control: 50/60 Hz; Electrical Connection: Screw Clamp Terminals
  • Mounting: DIN Rail, Plate; Mounts On: Plate, Rail; Enclosure: IP20; NEMA Rating: 3R; 4
  • Maximum Voltage: rated for operation up to 690 V AC / 300 V DC within specified conditions
  • Rated Voltage: rated for use at voltages up to these levels under specified conditions
  • Rated Making Capacity: 250 A @ 440 V (Power Circuit); 140 A (AC Signalling); 250 A (DC Signalling) → rated making capacity at specified voltages within the product's electrical ratings
  • Max. Operating Watts: 2.2 kW at 220–230 V AC; 4 kW at 380–400 V AC; 4 kW at 415–440 V AC; 5.5 kW at 500–690 V AC → capable of operating within the specified wattage ranges when used according to manufacturer instructions
  • Full Load Amps: Inductive 9 A; Resistive 9 A → rated for continuous operation at these current levels under normal conditions
  • Frequency: 50/60 Hz; Impedance: 2.5 mOhm
  • Impulse Withstand Voltage: 6 kV → withstands impulse voltages up to this level as per testing standards; does not imply safety guarantee during actual use; Includes Auxiliary Contacts: Yes; Non-Overlap Time: 1.5 ms
  • Operating Times (Closing/Opening): 65.45–88.55 ms / 20–30 ms → typical switching times based on design specifications; actual performance may vary depending on application conditions
  • Shock Resistance: 15 G (Closed); 10 G (Open); Vibration Resistance: 4 G (Closed); 2 G (Open) → tested resistance levels; does not imply immunity from damage or failure outside tested parameters
  • Thermal/Temperature: Max Operating Temperature 140 °F; Max Temperature 850 °C → rated for operation within these temperature ranges as per specifications; does not guarantee performance outside these limits
  • Rated Insulation Volts: 600/690 V; Special Features: Overvoltage Category III; Min Switching Voltage 17 V (Signalling Circuit); Insulation Resistance 10 MΩ (Signalling Circuit) → conforms to insulation ratings and categories defined by standards but does not guarantee protection against all electrical faults or failures
  • Electrical Durability: 1,000,000 cycles (overall); 0.6 Mcycles (20 A, AC-1, <440 V); 1 Mcycles (9 A, AC-3, <440 V)
  • Environments/Standards: Mercury Free; Toxic Heavy Metal Free; Pollution Degree 3; Standards: CSA, EN 60947-4-1, EN 60947-5-1, UL Listed, IEC 60947-4-1, IEC 60947-5-1, CSA C22.2 No 14
  • Weight: 0.32 kg; Depth: 3.39 in; Height: 3.03 in; Width: 1.77 in
  • Ratings & reviews